메뉴 건너뛰기




Volumn 78, Issue 3, 2006, Pages 558-569

Mechanical properties of porous, electrosprayed calcium phosphate coatings

Author keywords

Adhesion; Calcium phosphate coating; Electrostatic spray deposition; Mechanical properties; Scratch testing

Indexed keywords

CALCIUM PHOSPHATE COATING; CARBONATED HYDROXYAPATITE COATINGS; ELECTROSTATIC SPRAY DEPOSITION; SCRATCH TESTING;

EID: 33747410169     PISSN: 00219304     EISSN: 15524965     Source Type: Journal    
DOI: 10.1002/jbm.a.30770     Document Type: Article
Times cited : (24)

References (30)
  • 1
    • 0032723976 scopus 로고    scopus 로고
    • Bioactive ceramics: The effect of surface reactivity on bone formation and bone cell function
    • Ducheyne P, Qiu Q. Bioactive ceramics: The effect of surface reactivity on bone formation and bone cell function. Biomaterials 1999;20:2287-2303.
    • (1999) Biomaterials , vol.20 , pp. 2287-2303
    • Ducheyne, P.1    Qiu, Q.2
  • 2
    • 0027024821 scopus 로고
    • A brief introduction to advanced surface modification technologies
    • Wagner WC. A brief introduction to advanced surface modification technologies. J Oral Implantol 1992;18:231-235.
    • (1992) J Oral Implantol , vol.18 , pp. 231-235
    • Wagner, W.C.1
  • 4
    • 0028116539 scopus 로고
    • Retrieval studies on calcium phosphate-coated implants
    • Dhert WJ. Retrieval studies on calcium phosphate-coated implants. Med Prog Technol 1994;20:143-154.
    • (1994) Med Prog Technol , vol.20 , pp. 143-154
    • Dhert, W.J.1
  • 5
    • 0032240722 scopus 로고    scopus 로고
    • Current status of ceramic coatings for dental implants
    • Lacefield WR. Current status of ceramic coatings for dental implants. Implant Dent 1998;7:315-322.
    • (1998) Implant Dent , vol.7 , pp. 315-322
    • Lacefield, W.R.1
  • 6
    • 0033140441 scopus 로고    scopus 로고
    • Materials characteristics of uncoated/ceramic-coated implant materials
    • Lacefield WR. Materials characteristics of uncoated/ceramic-coated implant materials. Adv Dent Res 1999;13:21-26.
    • (1999) Adv Dent Res , vol.13 , pp. 21-26
    • Lacefield, W.R.1
  • 7
    • 0035190630 scopus 로고    scopus 로고
    • Hydroxyapatite femoral stems for total hip arthroplasty: 10- to 13- year followup
    • D'Antonio JA, Capello WN, Manley MT, Geesink R. Hydroxyapatite femoral stems for total hip arthroplasty: 10- to 13- year followup. Clin Orthop Relat Res 2001;393:101-111.
    • (2001) Clin Orthop Relat Res , vol.393 , pp. 101-111
    • D'Antonio, J.A.1    Capello, W.N.2    Manley, M.T.3    Geesink, R.4
  • 8
    • 3242681572 scopus 로고    scopus 로고
    • A review on calcium phosphate coatings produced using a sputtering process - An alternative to plasma spraying
    • Yang Y, Kim KH, Ong JL. A review on calcium phosphate coatings produced using a sputtering process-An alternative to plasma spraying. Biomaterials 2005;26:327-337.
    • (2005) Biomaterials , vol.26 , pp. 327-337
    • Yang, Y.1    Kim, K.H.2    Ong, J.L.3
  • 9
    • 22244467118 scopus 로고    scopus 로고
    • Influence of deposition parameters on chemical properties of calcium phosphate coatings prepared by using electrostatic spray deposition
    • Leeuwenburgh SCG, Wolke JGC, Schoonman J, Jansen JA. Influence of deposition parameters on chemical properties of calcium phosphate coatings prepared by using electrostatic spray deposition. J Biomed Mater Res 2005;74:275-284.
    • (2005) J Biomed Mater Res , vol.74 , pp. 275-284
    • Leeuwenburgh, S.C.G.1    Wolke, J.G.C.2    Schoonman, J.3    Jansen, J.A.4
  • 10
    • 9944248588 scopus 로고    scopus 로고
    • Influence of deposition parameters on morphological properties of biomedical calcium phosphate coatings prepared using electrostatic spray deposition
    • Leeuwenburgh SCG, Wolke JGC, Schoonman J, Jansen JA. Influence of deposition parameters on morphological properties of biomedical calcium phosphate coatings prepared using electrostatic spray deposition. Thin Solid Films 2005;472:105-113.
    • (2005) Thin Solid Films , vol.472 , pp. 105-113
    • Leeuwenburgh, S.C.G.1    Wolke, J.G.C.2    Schoonman, J.3    Jansen, J.A.4
  • 12
    • 0037210086 scopus 로고    scopus 로고
    • TEM and STEM analysis on heat-treated and in vitro plasma-sprayed hydroxyapatite/Ti-6A1-4V composite coatings
    • Dong ZL, Khor KA, Quek CH, White TJ, Cheang P. TEM and STEM analysis on heat-treated and in vitro plasma-sprayed hydroxyapatite/Ti-6A1-4V composite coatings. Biomaterials 2002;24:97-105.
    • (2002) Biomaterials , vol.24 , pp. 97-105
    • Dong, Z.L.1    Khor, K.A.2    Quek, C.H.3    White, T.J.4    Cheang, P.5
  • 13
    • 14644403695 scopus 로고    scopus 로고
    • Adherent apatite coating on titanium substrate using chemical deposition
    • Rohanizadeh R, LeGeros RZ, Harsono M, Bendavid A. Adherent apatite coating on titanium substrate using chemical deposition. J Biomed Mater Res 2005;72:428-438.
    • (2005) J Biomed Mater Res , vol.72 , pp. 428-438
    • Rohanizadeh, R.1    LeGeros, R.Z.2    Harsono, M.3    Bendavid, A.4
  • 14
    • 0032704098 scopus 로고    scopus 로고
    • Analytical and mechanical testing of high velocity oxy-fuel thermal sprayed and plasma sprayed calcium phosphate coatings
    • Haman JD, Chittur KK, Crawmer DE, Lucas LC. Analytical and mechanical testing of high velocity oxy-fuel thermal sprayed and plasma sprayed calcium phosphate coatings. J Biomed Mater Res 1999;48:856-860.
    • (1999) J Biomed Mater Res , vol.48 , pp. 856-860
    • Haman, J.D.1    Chittur, K.K.2    Crawmer, D.E.3    Lucas, L.C.4
  • 16
    • 0032868740 scopus 로고    scopus 로고
    • Fatigue behavior of calcium phosphate coatings with different stability under dry and wet conditions
    • Clemens JAM, Wolke JGC, Klein CP, de Groot K. Fatigue behavior of calcium phosphate coatings with different stability under dry and wet conditions. J Biomed Mater Res 1999;48: 741-748.
    • (1999) J Biomed Mater Res , vol.48 , pp. 741-748
    • Clemens, J.A.M.1    Wolke, J.G.C.2    Klein, C.P.3    De Groot, K.4
  • 17
    • 0031105712 scopus 로고    scopus 로고
    • Stability of radiofrequency magnetron sputtered calcium phosphate coatings under cyclically loaded conditions
    • Wolke JGC, van der Waerden JP, de Groot K, Jansen JA. Stability of radiofrequency magnetron sputtered calcium phosphate coatings under cyclically loaded conditions. Biomaterials 1997;18:483-488.
    • (1997) Biomaterials , vol.18 , pp. 483-488
    • Wolke, J.G.C.1    Van Der Waerden, J.P.2    De Groot, K.3    Jansen, J.A.4
  • 18
    • 4744365259 scopus 로고    scopus 로고
    • Theoretical analysis of calcium phosphate precipitation in simulated body fluid
    • Lu X, Leng Y. Theoretical analysis of calcium phosphate precipitation in simulated body fluid. Biomaterials 2005;26:1097-1108.
    • (2005) Biomaterials , vol.26 , pp. 1097-1108
    • Lu, X.1    Leng, Y.2
  • 19
    • 0026106027 scopus 로고
    • Microscratch and load relaxation tests for ultra-thin films
    • Wu TW. Microscratch and load relaxation tests for ultra-thin films. J Mater Res 1991;6:407-426.
    • (1991) J Mater Res , vol.6 , pp. 407-426
    • Wu, T.W.1
  • 20
    • 3142744620 scopus 로고    scopus 로고
    • Adhesion of calcium phosphate ceramic on polyethylene (PE), polystyrene (PS), polytetrafluoroethylene (PTFE), polydimethylsiloxane (PMDS), and poly-L-lactic acid (PLLA)
    • Feddes B, Wolke JGC, Weinhold WP, Vredenberg AM, Jansen JA. Adhesion of calcium phosphate ceramic on polyethylene (PE), polystyrene (PS), polytetrafluoroethylene (PTFE), polydimethylsiloxane (PMDS), and poly-L-lactic acid (PLLA). J Adhes Sci Technol 2004;18:655-672.
    • (2004) J Adhes Sci Technol , vol.18 , pp. 655-672
    • Feddes, B.1    Wolke, J.G.C.2    Weinhold, W.P.3    Vredenberg, A.M.4    Jansen, J.A.5
  • 21
  • 22
    • 0026360767 scopus 로고
    • Failure modes in scratch adhesion testing
    • Bull SJ. Failure modes in scratch adhesion testing. Surf Coat Technol 1991;50:25-32.
    • (1991) Surf Coat Technol , vol.50 , pp. 25-32
    • Bull, S.J.1
  • 23
    • 0242383942 scopus 로고    scopus 로고
    • Biomimetic and electrolytic calcium phosphate coatings on titanium alloy: Physicochemical characteristics and cell attachment
    • Wang J, Layrolle P, Stigter M, de Groot K. Biomimetic and electrolytic calcium phosphate coatings on titanium alloy: Physicochemical characteristics and cell attachment. Biomaterials 2004;25:583-592.
    • (2004) Biomaterials , vol.25 , pp. 583-592
    • Wang, J.1    Layrolle, P.2    Stigter, M.3    De Groot, K.4
  • 25
    • 0023450177 scopus 로고
    • Adhesion testing by the scratch method: The influence of intrinsic and extrinsic parameters on the critical load
    • Steinmann PA, Tardy Y, Hintermann HE. Adhesion testing by the scratch method: The influence of intrinsic and extrinsic parameters on the critical load. Thin Solid Films 1987;154:333-349.
    • (1987) Thin Solid Films , vol.154 , pp. 333-349
    • Steinmann, P.A.1    Tardy, Y.2    Hintermann, H.E.3
  • 26
    • 0023450182 scopus 로고
    • The relationship between hardness and scratch adhesion
    • Burnett PJ, Rickerby DS. The relationship between hardness and scratch adhesion. Thin Solid Films 1987;154:403-416.
    • (1987) Thin Solid Films , vol.154 , pp. 403-416
    • Burnett, P.J.1    Rickerby, D.S.2
  • 27
    • 0027940980 scopus 로고
    • Scratch indentation, a simple adhesion test method for thin films on polymeric supports
    • Vaughn GD, Frushour BG, Dale WC. Scratch indentation, a simple adhesion test method for thin films on polymeric supports. J Adhes Sci Technol 1994;8:635-650.
    • (1994) J Adhes Sci Technol , vol.8 , pp. 635-650
    • Vaughn, G.D.1    Frushour, B.G.2    Dale, W.C.3
  • 28
    • 33747384730 scopus 로고    scopus 로고
    • Bone supportive behaviour of calcium phosphate electrostatic spray deposition coated oral implants. An experimental study in goats
    • in press
    • Manders PJD, Wolke JGC, Jansen JA. Bone supportive behaviour of calcium phosphate electrostatic spray deposition coated oral implants. An experimental study in goats. Clin Oral Implants Res, in press.
    • Clin Oral Implants Res
    • Manders, P.J.D.1    Wolke, J.G.C.2    Jansen, J.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.