메뉴 건너뛰기




Volumn 48, Issue 5, 1999, Pages 741-748

Fatigue behavior of calcium phosphate coatings with different stability under dry and wet conditions

Author keywords

Coating failure; Crystallinity; Dissolution; Fatigue failure; Hydroxylapatite coating

Indexed keywords

BIOCOMPATIBILITY; BODY FLUIDS; BONE; CALCIUM COMPOUNDS; COMPUTER SIMULATION; DISSOLUTION; FAILURE (MECHANICAL); FATIGUE OF MATERIALS; HIP PROSTHESES; IMPLANTS (SURGICAL); RISK ASSESSMENT; WETTING;

EID: 0032868740     PISSN: 00219304     EISSN: None     Source Type: Journal    
DOI: 10.1002/(sici)1097-4636(1999)48:5<741::aid-jbm21>3.0.co;2-%23     Document Type: Article
Times cited : (33)

References (29)
  • 1
    • 0023499767 scopus 로고
    • Chemical implant fixation using hydroxyl-apatite coatings
    • Geesink RGT, de Groot K, Klein CPAT. Chemical implant fixation using hydroxyl-apatite coatings. Clin Orthop 1987;225: 147-170.
    • (1987) Clin Orthop , vol.225 , pp. 147-170
    • Geesink, R.G.T.1    De Groot, K.2    Klein, C.3
  • 3
    • 0025608937 scopus 로고
    • Hydroxylapatite-coated total hip prostheses, two year clinical and roentgenographic results of 100 cases
    • Geesink RGT. Hydroxylapatite-coated total hip prostheses, two year clinical and roentgenographic results of 100 cases. Clin Orthop 1990:261:39-58.
    • (1990) Clin Orthop , vol.261 , pp. 39-58
    • Geesink, R.G.T.1
  • 5
    • 0025859642 scopus 로고
    • Hydroxyapatite coating for prostheses
    • Morscher EW. Hydroxyapatite coating for prostheses. J Bone Joint Surg 1991;73(B):705-706.
    • (1991) J Bone Joint Surg , vol.73 , Issue.B , pp. 705-706
    • Morscher, E.W.1
  • 9
    • 0027992303 scopus 로고
    • Histology of tissue adjacent to an HAC-coated femoral prosthesis
    • Lintner F, Böhm G, Huber M, Scholz R. Histology of tissue adjacent to an HAC-coated femoral prosthesis. J Bone Joint Surg 1994;76(B):824-830.
    • (1994) J Bone Joint Surg , vol.76 , Issue.B , pp. 824-830
    • Lintner, F.1    Böhm, G.2    Huber, M.3    Scholz, R.4
  • 10
    • 0027458438 scopus 로고
    • The effect of calcium phosphate ceramic composition and structure on in vitro behavior; 1: Dissolution
    • Ducheyne P, Radin S, King L. The effect of calcium phosphate ceramic composition and structure on in vitro behavior; 1: Dissolution. J Biomed Mat Res 1993;27:25-34.
    • (1993) J Biomed Mat Res , vol.27 , pp. 25-34
    • Ducheyne, P.1    Radin, S.2    King, L.3
  • 13
    • 0027396826 scopus 로고
    • A histological and histomorphometrical investigation of fluorapatite, magnesium-whitlockite and hydroxylapatite plasma-sprayed coatings in goats
    • Dhert WJA, Klein CPAT, Jansen JA, van der Velde EA, Vriesde RC, Rozing PM, de Groot K. A histological and histomorphometrical investigation of fluorapatite, magnesium-whitlockite and hydroxylapatite plasma-sprayed coatings in goats. J Biomed Mater Res 1993:27:127-138.
    • (1993) J Biomed Mater Res , vol.27 , pp. 127-138
    • Dhert, W.J.A.1    Klein, C.2    Jansen, J.A.3    Van Der Velde, E.A.4    Vriesde, R.C.5    Rozing, P.M.6    De Groot, K.7
  • 14
    • 0026239712 scopus 로고
    • A mechanical investigation of fluorapatite, magnesium-whitlockite, and hydroxylapatite plasma-sprayed coatings in goats
    • Dhert WJA, Klein CPAT, Wolke JGC, van der Velde EA, de Groot K, Rozing PM. A mechanical investigation of fluorapatite, magnesium-whitlockite, and hydroxylapatite plasma-sprayed coatings in goats. J Biomed Mater Res 1991 ;25:1183-1200.
    • (1991) J Biomed Mater Res , vol.25 , pp. 1183-1200
    • Dhert, W.J.A.1    Klein, C.2    Wolke, J.G.C.3    Van Der Velde, E.A.4    De Groot, K.5    Rozing, P.M.6
  • 17
    • 0027335466 scopus 로고
    • Umlaufbiegeprüfung an mit hydroxylapatit plasmabeschichteten prüfkörpern aus Ti6A14V
    • Willmann G, Richter H, Wimmer M. Umlaufbiegeprüfung an mit Hydroxylapatit plasmabeschichteten Prüfkörpern aus Ti6A14V. Biomed Technik 1993;38:14-16.
    • (1993) Biomed Technik , vol.38 , pp. 14-16
    • Willmann, G.1    Richter, H.2    Wimmer, M.3
  • 19
    • 0026920955 scopus 로고
    • Stability of a cyclically loaded hydroxylapatite coating: Effect of substrate material, surface, preparation, and testing environment
    • Kummer FJ, Jaffe WL. Stability of a cyclically loaded hydroxylapatite coating: effect of substrate material, surface, preparation, and testing environment. J Applied Mat 1992:3:211-215.
    • (1992) J Applied Mat , vol.3 , pp. 211-215
    • Kummer, F.J.1    Jaffe, W.L.2
  • 20
    • 0028447410 scopus 로고
    • Stability of hydroxylapatite plasma-sprayed coated Ti-6A1-4V under cyclic bending in simulated physiological solutions
    • Reis RL, Monteiro FJ, Hastings GW. Stability of hydroxylapatite plasma-sprayed coated Ti-6A1-4V under cyclic bending in simulated physiological solutions. J Mat Sc Mat Med 1994;5: 457-462.
    • (1994) J Mat Sc Mat Med , vol.5 , pp. 457-462
    • Reis, R.L.1    Monteiro, F.J.2    Hastings, G.W.3
  • 21
    • 0011167843 scopus 로고
    • Effect of in vitro "aging" on the mechanical properties of plasma sprayed hydroxylapatite coatings on porous and non-porous titanium substrates
    • Ducheyne P, Christiansen D, editors. Oxford: Butterworth-Heinemann
    • Bearcroft JA, Robinson TJ, Beals NB. Effect of in vitro "aging" on the mechanical properties of plasma sprayed hydroxylapatite coatings on porous and non-porous titanium substrates. In: Ducheyne P, Christiansen D, editors. Bioceramics Vol. 6. Oxford: Butterworth-Heinemann; 1993.
    • (1993) Bioceramics , vol.6
    • Bearcroft, J.A.1    Robinson, T.J.2    Beals, N.B.3
  • 22
    • 0025104969 scopus 로고
    • Testing of total hip replacements: Endurance tests and stress measurements; Part 1: Endurance tests
    • Humphreys PK, Orr JF, Bahrani AS. Testing of total hip replacements: endurance tests and stress measurements; Part 1: endurance tests. Proc Mech Eng Eng Med 1990;204:29-34.
    • (1990) Proc Mech Eng Eng Med , vol.204 , pp. 29-34
    • Humphreys, P.K.1    Orr, J.F.2    Bahrani, A.S.3
  • 23
    • 0027533829 scopus 로고
    • The effect of dissolution on plasma sprayed hydroxylapatite coatings on titanium
    • Whitehead RY, Lucas LC, Lacefield WR. The effect of dissolution on plasma sprayed hydroxylapatite coatings on titanium. Clin Mat 1993;12:31-39.
    • (1993) Clin Mat , vol.12 , pp. 31-39
    • Whitehead, R.Y.1    Lucas, L.C.2    Lacefield, W.R.3
  • 24
    • 0026525198 scopus 로고
    • Mechanical failure of hydroxylapatite- and polysulfone coated titanium rods in a weight-bearing canine model
    • Shen WJ, Chung KC, Wang GJ, McLaughlin RE. Mechanical failure of hydroxylapatite- and polysulfone coated titanium rods in a weight-bearing canine model. J Arthropl 1992;7:43-49.
    • (1992) J Arthropl , vol.7 , pp. 43-49
    • Shen, W.J.1    Chung, K.C.2    Wang, G.J.3    McLaughlin, R.E.4
  • 25
    • 0002199480 scopus 로고
    • Plasma spraying induced changes of calcium phosphate ceramic characteristics and the effect on in vitro stability
    • Radin SR, Ducheyne P. Plasma spraying induced changes of calcium phosphate ceramic characteristics and the effect on in vitro stability. J Mat Sci Mat Med 1992;3:33-42.
    • (1992) J Mat Sci Mat Med , vol.3 , pp. 33-42
    • Radin, S.R.1    Ducheyne, P.2
  • 26
    • 0027897658 scopus 로고
    • Structure and integrity of a plasma-sprayed hydroxylapatite coating on titanium
    • Whitehead RY, Lacefield WR, Lucas LC. Structure and integrity of a plasma-sprayed hydroxylapatite coating on titanium. J Biomed Mater Res 1993 ;27:1501-1507.
    • (1993) J Biomed Mater Res , vol.27 , pp. 1501-1507
    • Whitehead, R.Y.1    Lacefield, W.R.2    Lucas, L.C.3
  • 27
    • 0028417132 scopus 로고
    • Microstructure and crystal-Unity in hydroxylapatite coatings
    • Chen J, Wolke JGC, de Groot K. Microstructure and crystal-Unity in hydroxylapatite coatings. Biomaterials 1994;15:396-399.
    • (1994) Biomaterials , vol.15 , pp. 396-399
    • Chen, J.1    Wolke, J.G.C.2    De Groot, K.3
  • 28
    • 0026239714 scopus 로고
    • Characterization of the interface in the plasma sprayed HA coating/Ti-6Al-4V implant system
    • Filiaggi MJ, Coombs NA, Pillair RM. Characterization of the interface in the plasma sprayed HA coating/Ti-6Al-4V implant system. J Biomed Mat Res 1991;25:1211-1229.
    • (1991) J Biomed Mat Res , vol.25 , pp. 1211-1229
    • Filiaggi, M.J.1    Coombs, N.A.2    Pillair, R.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.