메뉴 건너뛰기




Volumn 19, Issue 3, 2005, Pages 327-332

Varying effects of corneal thickness on intraocular pressure measurements with different tonometers

Author keywords

Corneal thickness; Intraocular pressure measurement; Tonometry

Indexed keywords

ADULT; AGED; ANALYSIS OF VARIANCE; ANALYTICAL PARAMETERS; ARTICLE; BLOOD FLOW; CALCULATION; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; CORNEA THICKNESS; CORRELATION ANALYSIS; ECHOOCULOGRAPHY; ERROR; FEMALE; HUMAN; INTERMETHOD COMPARISON; INTRAOCULAR PRESSURE; LINEAR REGRESSION ANALYSIS; MAJOR CLINICAL STUDY; MALE; OCULAR BLOOD VESSEL; OCULOPLETHYSMOGRAPHY; PRESSURE MEASUREMENT; RANDOMIZED CONTROLLED TRIAL; REFERENCE VALUE; TONOMETER;

EID: 16844376246     PISSN: 0950222X     EISSN: None     Source Type: Journal    
DOI: 10.1038/sj.eye.6701458     Document Type: Article
Times cited : (100)

References (25)
  • 1
    • 0029609715 scopus 로고
    • Ocular hypertension and central corneal thickness
    • Argus WA. Ocular hypertension and central corneal thickness. Ophthalmology 1995; 102: 1810-1812.
    • (1995) Ophthalmology , vol.102 , pp. 1810-1812
    • Argus, W.A.1
  • 3
    • 0032936567 scopus 로고    scopus 로고
    • Corneal thickness in ocular hypertension, primary open-angle glaucoma, and normal tension glaucoma
    • Copt RP, Thomas R, Mermoud A. Corneal thickness in ocular hypertension, primary open-angle glaucoma, and normal tension glaucoma. Arch Ophthalmol 1999; 117: 14-16.
    • (1999) Arch. Ophthalmol. , vol.117 , pp. 14-16
    • Copt, R.P.1    Thomas, R.2    Mermoud, A.3
  • 4
    • 0034803965 scopus 로고    scopus 로고
    • Central corneal thickness in the ocular hypertension treatment study (OHTS)
    • the Ocular Hypertension Treatment Study (OHTS) group
    • Brandt JD, Beiser JA, Kass MA, Gordon MO, the Ocular Hypertension Treatment Study (OHTS) group. Central corneal thickness in the ocular hypertension treatment study (OHTS). Ophthalmology 2001; 108: 1779-1788.
    • (2001) Ophthalmology , vol.108 , pp. 1779-1788
    • Brandt, J.D.1    Beiser, J.A.2    Kass, M.A.3    Gordon, M.O.4
  • 5
    • 70449195078 scopus 로고
    • Über applanationstonometrie
    • Goldmann H, Schmidt T. Über applanationstonometrie. Ophthalmologica 1957; 134: 221-242.
    • (1957) Ophthalmologica , vol.134 , pp. 221-242
    • Goldmann, H.1    Schmidt, T.2
  • 7
    • 0027269723 scopus 로고
    • The effect of corneal thickness on applanation tonometry
    • Whitacre MM, Stein RA, Hassanein K. The effect of corneal thickness on applanation tonometry. Am J Ophthalmol 1993; 115 592-596.
    • (1993) Am. J. Ophthalmol. , vol.115 , pp. 592-596
    • Whitacre, M.M.1    Stein, R.A.2    Hassanein, K.3
  • 8
    • 0017840770 scopus 로고
    • Increased corneal thickness simulating elevated intraocular pressure
    • Johnson M, Kass MA, Moses RA, Grodzki WJ. Increased corneal thickness simulating elevated intraocular pressure. Arch Ophthalmol 1978; 96: 664-665.
    • (1978) Arch. Ophthalmol. , vol.96 , pp. 664-665
    • Johnson, M.1    Kass, M.A.2    Moses, R.A.3    Grodzki, W.J.4
  • 10
    • 0034603359 scopus 로고    scopus 로고
    • Human corneal thickness and its impact on intraocular pressure measures: A review and meta-analysis approach
    • Doughty MJ, Zaman ML. Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach. Surv Ophthalmol 2000; 44: 367-408.
    • (2000) Surv. Ophthalmol. , vol.44 , pp. 367-408
    • Doughty, M.J.1    Zaman, M.L.2
  • 13
    • 0016701918 scopus 로고
    • The noncontact tonometer. Clinical evaluation on normal and diseased eyes
    • Sørensen PN. The noncontact tonometer. Clinical evaluation on normal and diseased eyes. Acta Ophthalmol 1975; 53: 513-521.
    • (1975) Acta Ophthalmol. , vol.53 , pp. 513-521
    • Sørensen, P.N.1
  • 14
    • 0031003564 scopus 로고    scopus 로고
    • A comparison of intraocular pressure measurements with the XPERT noncontact tonometer and Goldmann applanation tonometry
    • Popovich KS, Shields MB. A comparison of intraocular pressure measurements with the XPERT noncontact tonometer and Goldmann applanation tonometry. J Glaucoma 1997; 6: 44-46.
    • (1997) J. Glaucoma , vol.6 , pp. 44-46
    • Popovich, K.S.1    Shields, M.B.2
  • 15
    • 0036257336 scopus 로고    scopus 로고
    • Central corneal thickness, radius of the corneal curvature and intraocular pressure in normal subjects using non-contact techniques: Reykjavik eye study
    • Eysteinsson T, Jonasson F, Sasaki H, Arnarsson A, Sverrisson T, Sasaki K et al. Central corneal thickness, radius of the corneal curvature and intraocular pressure in normal subjects using non-contact techniques: Reykjavik eye study. Acta Ophthalmol Scand 2002; 80 11-15.
    • (2002) Acta Ophthalmol. Scand. , vol.80 , pp. 11-15
    • Eysteinsson, T.1    Jonasson, F.2    Sasaki, H.3    Arnarsson, A.4    Sverrisson, T.5    Sasaki, K.6
  • 16
    • 0035164733 scopus 로고    scopus 로고
    • Relation between corneal thickness and intraocular pressure measurement by noncontact and applanation tonometry
    • Recep ÖF, Hasiripi HH, Çaǧil N, Sarikatipoǧlu H. Relation between corneal thickness and intraocular pressure measurement by noncontact and applanation tonometry. J Cataract Refract Surg 2001; 27: 1781-1791.
    • (2001) J. Cataract Refract. Surg. , vol.27 , pp. 1781-1791
    • Recep, Ö.F.1    Hasiripi, H.H.2    Çaǧil, N.3    Sarikatipoǧlu, H.4
  • 17
    • 0028432917 scopus 로고
    • Validity of pulsatile ocular blood flow measurements
    • Silver DM, Farrell RA. Validity of pulsatile ocular blood flow measurements. Surv Ophthalmol 1994; 38 (Suppl): S72-S80.
    • (1994) Surv. Ophthalmol. , vol.38 , Issue.SUPPL.
    • Silver, D.M.1    Farrell, R.A.2
  • 18
    • 0032470563 scopus 로고    scopus 로고
    • Reliability of intraocular pressure measurements after myopic excimer photorefractive keratectomy
    • Abbasoglu CE, Bowman RW, Cavanagh HD, McCulley JP. Reliability of intraocular pressure measurements after myopic excimer photorefractive keratectomy. Ophthalmology 1998; 105: 2193-2196.
    • (1998) Ophthalmology , vol.105 , pp. 2193-2196
    • Abbasoglu, C.E.1    Bowman, R.W.2    Cavanagh, H.D.3    McCulley, J.P.4
  • 20
    • 0036235038 scopus 로고    scopus 로고
    • Effect of corneal thickness on intraocular pressure measurements with the pneumotonometer, Goldmann applanation tonometer and Tono-pen
    • Bhan A, Browning AC, Shah S, Hamilton R, Dave D, Dua HS. Effect of corneal thickness on intraocular pressure measurements with the pneumotonometer, Goldmann applanation tonometer and Tono-pen. Invest Ophthalmol Vis Sci 2002; 43: 1389-1392.
    • (2002) Invest. Ophthalmol. Vis. Sci. , vol.43 , pp. 1389-1392
    • Bhan, A.1    Browning, A.C.2    Shah, S.3    Hamilton, R.4    Dave, D.5    Dua, H.S.6
  • 21
    • 0036963538 scopus 로고    scopus 로고
    • The effect of corneal thickness and corneal curvature on pneumotonometer measurements
    • Morgan AJ, Harper J, Hosking SL, Gilmartin B. The effect of corneal thickness and corneal curvature on pneumotonometer measurements. Curr Eye Res 2002; 25: 107-112.
    • (2002) Curr. Eye Res. , vol.25 , pp. 107-112
    • Morgan, A.J.1    Harper, J.2    Hosking, S.L.3    Gilmartin, B.4
  • 22
    • 0034971648 scopus 로고    scopus 로고
    • Central corneal thickness, tonometry and ocular dimensions in glaucoma and ocular hypertension
    • Singh RP, Goldberg I, Graham SL, Sharma A, Mohsin M. Central corneal thickness, tonometry and ocular dimensions in glaucoma and ocular hypertension. J Glaucoma 2001; 10: 206-210.
    • (2001) J. Glaucoma , vol.10 , pp. 206-210
    • Singh, R.P.1    Goldberg, I.2    Graham, S.L.3    Sharma, A.4    Mohsin, M.5
  • 23
    • 0034441936 scopus 로고    scopus 로고
    • Influence of keratometric readings on comparative intraocular pressure measurements with Goldmann, Tono-pen, and noncontact tonometers
    • Paranhos A, Paranhos FR, Prata JA, Omi CA, Mello PAA, Shields MB. Influence of keratometric readings on comparative intraocular pressure measurements with Goldmann, Tono-pen, and noncontact tonometers. J Glaucoma 2000; 9: 219-233.
    • (2000) J. Glaucoma , vol.9 , pp. 219-233
    • Paranhos, A.1    Paranhos, F.R.2    Prata, J.A.3    Omi, C.A.4    Mello, P.A.A.5    Shields, M.B.6
  • 24
    • 0141682012 scopus 로고    scopus 로고
    • Intraocular pressure, Goldmann applanation tension, corneal thickness, and corneal curvature in Caucasians, Asians, Hispanics and African Americans
    • Shimmyo M, Ross AJ, Moy A, Mostafavi R. Intraocular pressure, Goldmann applanation tension, corneal thickness, and corneal curvature in Caucasians, Asians, Hispanics and African Americans. Am J Ophthalmol 2003; 136: 603-613.
    • (2003) Am. J. Ophthalmol. , vol.136 , pp. 603-613
    • Shimmyo, M.1    Ross, A.J.2    Moy, A.3    Mostafavi, R.4
  • 25
    • 0033021344 scopus 로고    scopus 로고
    • Determination of the true intraocular pressure and modulus of elasticity of the human cornea in vivo
    • Orssengo GJ, Pye DC. Determination of the true intraocular pressure and modulus of elasticity of the human cornea in vivo. Bull Math Biol 1999; 61: 551-572.
    • (1999) Bull. Math Biol. , vol.61 , pp. 551-572
    • Orssengo, G.J.1    Pye, D.C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.