메뉴 건너뛰기




Volumn 29, Issue 8, 2006, Pages 810-815

Inappropriate ICD therapy: Does device configuration make a difference

Author keywords

Complications; Implantable defibrillator; Inappropriate shocks; Sinus tachycardia; Supraventricular arrhythmias

Indexed keywords

ACETYLSALICYLIC ACID; AMIODARONE; ANTIARRHYTHMIC AGENT; BETA ADRENERGIC RECEPTOR BLOCKING AGENT; CALCIUM CHANNEL BLOCKING AGENT; CARDIAC AGENT; DIGOXIN; DIURETIC AGENT; NITRATE; SOTALOL;

EID: 33747137546     PISSN: 01478389     EISSN: 15408159     Source Type: Journal    
DOI: 10.1111/j.1540-8159.2006.00445.x     Document Type: Review
Times cited : (21)

References (31)
  • 2
    • 0027192356 scopus 로고
    • Shock occurrence and survival in 241 patients with implantable cardioverter-defibrillator therapy
    • Grimm W, Flores BT, Marchlinski FE. Shock occurrence and survival in 241 patients with implantable cardioverter-defibrillator therapy. Circulation 1993; 87:1880-1888.
    • (1993) Circulation , vol.87 , pp. 1880-1888
    • Grimm, W.1    Flores, B.T.2    Marchlinski, F.E.3
  • 3
    • 0024463229 scopus 로고
    • Actuarial incidence and pattern of occurrence of shocks following implantation of the automatic implantable cardioverter defibrillator
    • Fogoros RN, Elson JJ, Bonnet CA. Actuarial incidence and pattern of occurrence of shocks following implantation of the automatic implantable cardioverter defibrillator. Pacing Clin Electrophysiol 1989; 12:1465-1473.
    • (1989) Pacing Clin Electrophysiol , vol.12 , pp. 1465-1473
    • Fogoros, R.N.1    Elson, J.J.2    Bonnet, C.A.3
  • 4
    • 0032544215 scopus 로고    scopus 로고
    • Adverse events with transvenous implantable cardioverter-defibrillators: A prospective multicenter study
    • European 7219 Jewel ICD investigators
    • Rosenqvist M, Block M, den Dulk K, Minten J, Lindemans F. Adverse events with transvenous implantable cardioverter-defibrillators: A prospective multicenter study. European 7219 Jewel ICD investigators. Circulation 1998; 98:663-670.
    • (1998) Circulation , vol.98 , pp. 663-670
    • Rosenqvist, M.1    Block, M.2    Den Dulk, K.3    Minten, J.4    Lindemans, F.5
  • 5
    • 0034078756 scopus 로고    scopus 로고
    • Inappropriate therapy from atrial fibrillation and sinus tachycardia in automated implantable cardioverter defibrillators
    • Nanthakumar K, Paquette M, Newman D, Deno DC, Malden L, Gunderson B, Gilkerson J, et al. Inappropriate therapy from atrial fibrillation and sinus tachycardia in automated implantable cardioverter defibrillators. Am Heart J 2000; 139:797-803.
    • (2000) Am Heart J , vol.139 , pp. 797-803
    • Nanthakumar, K.1    Paquette, M.2    Newman, D.3    Deno, D.C.4    Malden, L.5    Gunderson, B.6    Gilkerson, J.7
  • 6
    • 0033060186 scopus 로고    scopus 로고
    • Inappropriate implantable cardioverter-defibrillator therapy due to the detection of premature ventricular complexes
    • Goldberger JJ, Horvath G, Challapalli R, Kadish AH. Inappropriate implantable cardioverter-defibrillator therapy due to the detection of premature ventricular complexes. Pacing Clin Electrophysiol 1999; 22:825-828.
    • (1999) Pacing Clin Electrophysiol , vol.22 , pp. 825-828
    • Goldberger, J.J.1    Horvath, G.2    Challapalli, R.3    Kadish, A.H.4
  • 7
    • 0036743164 scopus 로고    scopus 로고
    • Case of bad timing: Inappropriate implantable cardioverter defibrillator therapy due to a critically placed premature ventricular contraction
    • Healy E, Ngarmukos T, Rosenthal L. Case of bad timing: Inappropriate implantable cardioverter defibrillator therapy due to a critically placed premature ventricular contraction. Pacing Clin Electrophysiol 2002; 25:1403-1405.
    • (2002) Pacing Clin Electrophysiol , vol.25 , pp. 1403-1405
    • Healy, E.1    Ngarmukos, T.2    Rosenthal, L.3
  • 8
    • 0035344302 scopus 로고    scopus 로고
    • Inappropriate ICD therapy due to lead-related noise in an active fixation ICD lead
    • Mela T, Ngarmukos T, Rosenthal L, Mittleman R. Inappropriate ICD therapy due to lead-related noise in an active fixation ICD lead. J Invasive Cardiol 2001; 13:406-408.
    • (2001) J Invasive Cardiol , vol.13 , pp. 406-408
    • Mela, T.1    Ngarmukos, T.2    Rosenthal, L.3    Mittleman, R.4
  • 9
    • 0028261802 scopus 로고
    • Inappropriate discharge by an implantable cardioverter defibrillator: Recognition of myopotential sensing using telemetered intracardiac electrograms
    • Sandler MJ, Kutalek SP. Inappropriate discharge by an implantable cardioverter defibrillator: Recognition of myopotential sensing using telemetered intracardiac electrograms. Pacing Clin Electrophysiol 1994; 17:665-671.
    • (1994) Pacing Clin Electrophysiol , vol.17 , pp. 665-671
    • Sandler, M.J.1    Kutalek, S.P.2
  • 10
    • 0034935372 scopus 로고    scopus 로고
    • Inappropriate discharges from an intravenous implantable cardioverter defibrillator due to T-wave oversensing
    • Washizuka T, Chinushi M, Kasai H, Watanabe H, Tagawa M, Hosaka Y, Abe A, et al. Inappropriate discharges from an intravenous implantable cardioverter defibrillator due to T-wave oversensing. Jpn Circ J 2001; 65:685-687.
    • (2001) Jpn Circ J , vol.65 , pp. 685-687
    • Washizuka, T.1    Chinushi, M.2    Kasai, H.3    Watanabe, H.4    Tagawa, M.5    Hosaka, Y.6    Abe, A.7
  • 11
    • 0033762014 scopus 로고    scopus 로고
    • Intradevice interaction in a dual chamber implantable cardioverter defibrillator preventing ventricular tachyarrhythmia detection
    • Shivkumar K, Feliciano Z, Boyle NG, Wiener I. Intradevice interaction in a dual chamber implantable cardioverter defibrillator preventing ventricular tachyarrhythmia detection. J Cardiovasc Electrophysiol 2000; 11:1285-1288.
    • (2000) J Cardiovasc Electrophysiol , vol.11 , pp. 1285-1288
    • Shivkumar, K.1    Feliciano, Z.2    Boyle, N.G.3    Wiener, I.4
  • 12
    • 0034888919 scopus 로고    scopus 로고
    • Far-field R wave oversensing in a dual chamber arrhythmia management device: Predisposing factors and practical implications
    • Weretka S, Becker R, Hilbel T, Karle C, Osswald BR, Kuebler W, Schoels W. Far-field R wave oversensing in a dual chamber arrhythmia management device: Predisposing factors and practical implications. Pacing Clin Electrophysiol 2001; 24:1240-1246.
    • (2001) Pacing Clin Electrophysiol , vol.24 , pp. 1240-1246
    • Weretka, S.1    Becker, R.2    Hilbel, T.3    Karle, C.4    Osswald, B.R.5    Kuebler, W.6    Schoels, W.7
  • 13
    • 0036023341 scopus 로고    scopus 로고
    • High incidence of device-related and lead-related complications in the dual-chamber implantable cardioverter defibrillator compared with the single-chamber version
    • Takahashi T, Bhandari AK, Watanuki M, Cannom DS, Sakurada H, Hiraoka M. High incidence of device-related and lead-related complications in the dual-chamber implantable cardioverter defibrillator compared with the single-chamber version. Circ J 2002; 66:746-750.
    • (2002) Circ J , vol.66 , pp. 746-750
    • Takahashi, T.1    Bhandari, A.K.2    Watanuki, M.3    Cannom, D.S.4    Sakurada, H.5    Hiraoka, M.6
  • 14
    • 0034958429 scopus 로고    scopus 로고
    • Inappropriate shock delivery due to ventricular double detection with a biventricular pacing implantable cardioverter defibrillator
    • Schreieck J, Zrenner B, Kolb C, Ndrepepa G, Schmitt C. Inappropriate shock delivery due to ventricular double detection with a biventricular pacing implantable cardioverter defibrillator. Pacing Clin Electrophysiol 2001; 24:1154-1157.
    • (2001) Pacing Clin Electrophysiol , vol.24 , pp. 1154-1157
    • Schreieck, J.1    Zrenner, B.2    Kolb, C.3    Ndrepepa, G.4    Schmitt, C.5
  • 15
    • 0033779165 scopus 로고    scopus 로고
    • Dual chamber arrhythmia detection in the implantable cardioverter defibrillator
    • Dijkman B, Wellens HJ. Dual chamber arrhythmia detection in the implantable cardioverter defibrillator. J Cardiovasc Electrophysiol 2000; 11:1105-1115.
    • (2000) J Cardiovasc Electrophysiol , vol.11 , pp. 1105-1115
    • Dijkman, B.1    Wellens, H.J.2
  • 16
    • 0033108192 scopus 로고    scopus 로고
    • First worldwide clinical experience with a new dual chamber implantable cardioverter defibrillator. Advantages and complications
    • The Ventak AV II DR investigators
    • Sticherling C, Schaumann A, Klingenheben T, Hohnloser SH. First worldwide clinical experience with a new dual chamber implantable cardioverter defibrillator. Advantages and complications. The Ventak AV II DR investigators. Europace 1999; 1:96-102.
    • (1999) Europace , vol.1 , pp. 96-102
    • Sticherling, C.1    Schaumann, A.2    Klingenheben, T.3    Hohnloser, S.H.4
  • 17
    • 0035115761 scopus 로고    scopus 로고
    • Do current dual chamber cardioverter defibrillators have advantages over conventional single chamber cardioverter defibrillators in reducing inappropriate therapies? A randomized, prospective study
    • Deisenhofer I, Kolb C, Ndrepepa G, Schreieck J, Karch M, Schmieder S, Zrenner B, et al. Do current dual chamber cardioverter defibrillators have advantages over conventional single chamber cardioverter defibrillators in reducing inappropriate therapies? A randomized, prospective study. J Cardiovasc Electrophysiol 2001; 12:134-142.
    • (2001) J Cardiovasc Electrophysiol , vol.12 , pp. 134-142
    • Deisenhofer, I.1    Kolb, C.2    Ndrepepa, G.3    Schreieck, J.4    Karch, M.5    Schmieder, S.6    Zrenner, B.7
  • 18
    • 0033545689 scopus 로고    scopus 로고
    • Single-chamber versus dual-chamber implantable cardioverter defibrillators: Indications and clinical results
    • Trappe HJ, Achtelik M, Pfitzner P, Voigt B, Weismuller P. Single-chamber versus dual-chamber implantable cardioverter defibrillators: Indications and clinical results. Am J Cardiol 1999; 83:8D-16D.
    • (1999) Am J Cardiol , vol.83
    • Trappe, H.J.1    Achtelik, M.2    Pfitzner, P.3    Voigt, B.4    Weismuller, P.5
  • 19
    • 0036852227 scopus 로고    scopus 로고
    • A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/NASPE Committee to Update the 1998 Pacemaker Guidelines)
    • Gregoratos G, Abrams J, Epstein AE, Freedman RA, Hayes DL, Hlatky MA, Kerber RE, et al. A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/NASPE Committee to Update the 1998 Pacemaker Guidelines). J Cardiovasc Electrophysiol 2002; 13:1183-1199.
    • (2002) J Cardiovasc Electrophysiol , vol.13 , pp. 1183-1199
    • Gregoratos, G.1    Abrams, J.2    Epstein, A.E.3    Freedman, R.A.4    Hayes, D.L.5    Hlatky, M.A.6    Kerber, R.E.7
  • 20
    • 0029126467 scopus 로고
    • The proarrhythmic potential of implantable cardioverter-defibrillators
    • Pinski SL, Fahy GJ. The proarrhythmic potential of implantable cardioverter-defibrillators. Circulation 1995; 92:1651-1664.
    • (1995) Circulation , vol.92 , pp. 1651-1664
    • Pinski, S.L.1    Fahy, G.J.2
  • 21
    • 0031818491 scopus 로고    scopus 로고
    • Electrical proarrhythmia: Induction of inappropriate atrial therapies due to far-field R wave oversensing in a new dual chamber defibrillator
    • Wolpert C, Jung W, Scholl C, Spehl S, Cyran J, Luderitz B. Electrical proarrhythmia: Induction of inappropriate atrial therapies due to far-field R wave oversensing in a new dual chamber defibrillator. J Cardiovasc Electrophysiol 1998; 9:859-863.
    • (1998) J Cardiovasc Electrophysiol , vol.9 , pp. 859-863
    • Wolpert, C.1    Jung, W.2    Scholl, C.3    Spehl, S.4    Cyran, J.5    Luderitz, B.6
  • 22
    • 0037176263 scopus 로고    scopus 로고
    • Dual Chamber and VVI Implantable Defibrillator Trial Investigators. Dual-chamber pacing or ventricular backup pacing in patients with an implantable defibrillator: The Dual Chamber and VVI Implantable Defibrillator (DAVID) Trial
    • Wilkoff BL, Cook JR, Epstein AE, Greene HL, Hallstrom AP, Hsia H, Kutalek SP, et al. Dual Chamber and VVI Implantable Defibrillator Trial Investigators. Dual-chamber pacing or ventricular backup pacing in patients with an implantable defibrillator: The Dual Chamber and VVI Implantable Defibrillator (DAVID) Trial. JAMA 2002; 288:3115-3123.
    • (2002) JAMA , vol.288 , pp. 3115-3123
    • Wilkoff, B.L.1    Cook, J.R.2    Epstein, A.E.3    Greene, H.L.4    Hallstrom, A.P.5    Hsia, H.6    Kutalek, S.P.7
  • 23
    • 0034543628 scopus 로고    scopus 로고
    • Importance of the atrial channel for ventricular arrhythmia therapy in the dual chamber implantable cardioverter defibrillator
    • Dijkman B, Wellens HJ. Importance of the atrial channel for ventricular arrhythmia therapy in the dual chamber implantable cardioverter defibrillator. J Cardiovasc Electrophysiol 2000; 11:1309-1319.
    • (2000) J Cardiovasc Electrophysiol , vol.11 , pp. 1309-1319
    • Dijkman, B.1    Wellens, H.J.2
  • 24
    • 0035049643 scopus 로고    scopus 로고
    • Indications for dual-chamber cardioverter defibrillators at implant and at 1 year follow-up: A retrospective analysis in the single-chamber defibrillator era
    • Proclemer A, Della Bella P, Facchin D, Fattore L, Carbucicchio C, Tondo C, Lunati M, et al. Indications for dual-chamber cardioverter defibrillators at implant and at 1 year follow-up: A retrospective analysis in the single-chamber defibrillator era. Europace 2001; 3:132-135.
    • (2001) Europace , vol.3 , pp. 132-135
    • Proclemer, A.1    Della Bella, P.2    Facchin, D.3    Fattore, L.4    Carbucicchio, C.5    Tondo, C.6    Lunati, M.7
  • 26
    • 0027229344 scopus 로고
    • The influence of atrial fibrillation on prognosis in mild to moderate heart failure. The V-HeFT Studies
    • The V-HeFT VA Cooperative Studies Group
    • Carson PE, Johnson GR, Dunkman WB, Fletcher RD, Farrell L, Cohn JN. The influence of atrial fibrillation on prognosis in mild to moderate heart failure. The V-HeFT Studies. The V-HeFT VA Cooperative Studies Group. Circulation 1993; 87:VI102-VI110.
    • (1993) Circulation , vol.87
    • Carson, P.E.1    Johnson, G.R.2    Dunkman, W.B.3    Fletcher, R.D.4    Farrell, L.5    Cohn, J.N.6
  • 27
    • 0037862052 scopus 로고    scopus 로고
    • Worldwide utilization of implantable cardioverter/defibrillators now and in the future
    • Seidl K, Senges J. Worldwide utilization of implantable cardioverter/defibrillators now and in the future. Card Electrophysiol Rev 2003; 7:5-13.
    • (2003) Card Electrophysiol Rev , vol.7 , pp. 5-13
    • Seidl, K.1    Senges, J.2
  • 28
    • 0036152448 scopus 로고    scopus 로고
    • Implantable cardioverter defibrillator utilization based on discharge diagnoses from Medicare and managed care patients
    • Ruskin JN, Camm AJ, Zipes DP, Hallstrom AP, McGrory-Usset ME. Implantable cardioverter defibrillator utilization based on discharge diagnoses from Medicare and managed care patients. J Cardiovasc Electrophysiol 2002; 13:38-43.
    • (2002) J Cardiovasc Electrophysiol , vol.13 , pp. 38-43
    • Ruskin, J.N.1    Camm, A.J.2    Zipes, D.P.3    Hallstrom, A.P.4    McGrory-Usset, M.E.5
  • 30
    • 0032104051 scopus 로고    scopus 로고
    • Indications for implantation of a dual-chamber pacemaker combined with an implantable cardioverter-defibrillator
    • Higgins SL, Williams SK, Pak JP, Meyer DB. Indications for implantation of a dual-chamber pacemaker combined with an implantable cardioverter- defibrillator. Am J Cardiol 1998; 81:1360-1362.
    • (1998) Am J Cardiol , vol.81 , pp. 1360-1362
    • Higgins, S.L.1    Williams, S.K.2    Pak, J.P.3    Meyer, D.B.4
  • 31
    • 0030663939 scopus 로고    scopus 로고
    • Long-term follow-up of patients treated with implantable cardioverter defibrillators in a Danish centre. Accurrence ICD therapy and patient survivors
    • Nielsen JC, Mortensen PT, Pedersen AK. Long-term follow-up of patients treated with implantable cardioverter defibrillators in a Danish centre. Accurrence ICD therapy and patient survivors. Scand Cardiovasc J 1997; 31:151-156.
    • (1997) Scand Cardiovasc J , vol.31 , pp. 151-156
    • Nielsen, J.C.1    Mortensen, P.T.2    Pedersen, A.K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.