메뉴 건너뛰기




Volumn 12, Issue 2, 2001, Pages 134-142

Do current dual chamber cardioverter defibrillators have advantages over conventional single chamber cardioverter defibrillators in reducing inappropriate therapies? A randomized, prospective study

Author keywords

Atrial fibrillation; Detection algorithm; Dual chamber implantable cardioverter defibrillator; Inappropriate therapy

Indexed keywords

ADULT; AGED; ALGORITHM; ARTICLE; CARDIOVERSION; DEFIBRILLATOR; DISEASE CLASSIFICATION; FEMALE; FOLLOW UP; HEART VENTRICLE FIBRILLATION; HEART VENTRICLE TACHYCARDIA; HUMAN; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; PROSPECTIVE STUDY; SUPRAVENTRICULAR TACHYCARDIA; TREATMENT PLANNING;

EID: 0035115761     PISSN: 10453873     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1540-8167.2001.00134.x     Document Type: Article
Times cited : (161)

References (32)
  • 2
    • 0026448128 scopus 로고
    • Electrocardiographically documented unnecessary, spontaneous shocks in 241 patients with implantable cardioverter defibrillators
    • (1992) PACE , vol.15 , pp. 1667-1673
    • Grimm, W.1    Flores, B.F.2    Marchlinski, F.E.3
  • 6
    • 0027978501 scopus 로고
    • Clinical experience with a new cardioverter defibrillator capable of biphasic waveform pulse and enhanced data storage: Results of a prospective multicenter study
    • European Ventak P2 Investigator Group
    • (1994) PACE , vol.17 , pp. 1243-1255
    • Neuzner, J.1
  • 15
    • 0032053695 scopus 로고    scopus 로고
    • The ACC/AHA Task Force on Practice Guidelines: ACC/AHA guidelines for implantation of cardiac pacemakers and antiarrhythmic devices: A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines
    • Committee on Pacemaker Implantation
    • (1998) J Am Coll Cardiol , vol.31 , pp. 1175-1209
  • 27
    • 0031058998 scopus 로고    scopus 로고
    • Automatic arrhythmia identification using analysis of the atrioventricular association. Application to a new generation of implantable defibrillators
    • Participating Centers of the Automatic Recognition of Arrhythmia Study Group
    • (1997) Circulation , vol.95 , pp. 967-973
    • Nair, M.1    Saoudi, N.2    Kroiss, D.3    Letac, B.4
  • 30
    • 0033053953 scopus 로고    scopus 로고
    • Inappropriate shocks delivered by implantable cardiac defibrillators during oversensing of activity of diaphragmatic muscle
    • (1999) Heart , vol.81 , pp. 94-96
    • Babuty, D.1    Fauchier, L.2    Cosnay, P.3
  • 31
    • 0031714215 scopus 로고    scopus 로고
    • Inappropriate shock therapy for nonsustained ventricular tachycardia in a dual chamber pacemaker defibrillator
    • (1998) PACE , vol.21 , pp. 2005-2006
    • Mann, D.E.1    Kelly, P.A.2    Reiter, M.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.