메뉴 건너뛰기




Volumn 27, Issue 4, 2006, Pages 895-901

Pitfalls in lactate measurements at 3T

Author keywords

[No Author keywords available]

Indexed keywords

3T NUCLEAR MAGNETIC RESONACE IMAGING; ARTICLE; CASE REPORT; DIAGNOSTIC ERROR; FALSE NEGATIVE RESULT; HUMAN; LACTIC ACIDOSIS; MELAS SYNDROME; NUCLEAR MAGNETIC RESONANCE IMAGING; NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY; PHANTOM; PREDICTION; SIGNAL DETECTION; BRAIN DISEASE; IMAGE QUALITY; LABORATORY DIAGNOSIS; METABOLISM;

EID: 33747131017     PISSN: 01956108     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (96)

References (13)
  • 2
    • 0031408219 scopus 로고    scopus 로고
    • Metabolite-specific NMR spectroscopy in vivo
    • Allen PS, Thompson RB, Wilman AH. Metabolite-specific NMR spectroscopy in vivo. NMR Biomed 1997;10:435-44
    • (1997) NMR Biomed , vol.10 , pp. 435-444
    • Allen, P.S.1    Thompson, R.B.2    Wilman, A.H.3
  • 3
    • 0031933967 scopus 로고    scopus 로고
    • Homonuclear J coupling effects in volume localized NMR spectroscopy: Pitfalls and solutions
    • Yablonskiy DA, Neil JJ, Raichle ME, et al. Homonuclear J coupling effects in volume localized NMR spectroscopy: pitfalls and solutions. Magn Reson Med 1998;39:159-78
    • (1998) Magn Reson Med , vol.39 , pp. 159-178
    • Yablonskiy, D.A.1    Neil, J.J.2    Raichle, M.E.3
  • 4
    • 0032947345 scopus 로고    scopus 로고
    • Lactate detection at 3T: Compensating J coupling effects with BASING
    • Kelley DAC, Lawrence LW, Star-Lack JM. Lactate detection at 3T: compensating J coupling effects with BASING. J Magn Reson Imaging 1999;9:732-37
    • (1999) J Magn Reson Imaging , vol.9 , pp. 732-737
    • Kelley, D.A.C.1    Lawrence, L.W.2    Star-Lack, J.M.3
  • 5
    • 0032134032 scopus 로고    scopus 로고
    • In vivo lactate editing with simultaneous detection of choline, creatine, NAA, and lipid singlets at 1.5 T using PRESS excitation with applications to the study of brain and head and neck tumors
    • Star-Lack J, Spielman D, Adalsteinsson E, et al. In vivo lactate editing with simultaneous detection of choline, creatine, NAA, and lipid singlets at 1.5 T using PRESS excitation with applications to the study of brain and head and neck tumors. J Magn Reson 1998;133:243-54
    • (1998) J Magn Reson , vol.133 , pp. 243-254
    • Star-Lack, J.1    Spielman, D.2    Adalsteinsson, E.3
  • 6
    • 0033970816 scopus 로고    scopus 로고
    • Very selective suppression pulses for clinical MRSI studies of brain and prostate cancer
    • Tran TK, Vigneron DB, Sailasuta N, et al. Very selective suppression pulses for clinical MRSI studies of brain and prostate cancer. Magn Reson Med 2000;43:23-33
    • (2000) Magn Reson Med , vol.43 , pp. 23-33
    • Tran, T.K.1    Vigneron, D.B.2    Sailasuta, N.3
  • 7
    • 0035742326 scopus 로고    scopus 로고
    • The return to frequency sweep: Designing adiabatic pulses for contemporary NMR
    • Garwood M, DelaBarre L. The return to frequency sweep: designing adiabatic pulses for contemporary NMR. Magn Reson Med 2001;153:155-77
    • (2001) Magn Reson Med , vol.153 , pp. 155-177
    • Garwood, M.1    DelaBarre, L.2
  • 8
    • 0028935322 scopus 로고
    • Lactate quantification by means of PRESS spectroscopy: Influence of refocusing pulses and timing scheme
    • Schick F, Nagele T, Klose U, et al. Lactate quantification by means of PRESS spectroscopy: influence of refocusing pulses and timing scheme. Magn Reson Imaging 1995;13:309-19
    • (1995) Magn Reson Imaging , vol.13 , pp. 309-319
    • Schick, F.1    Nagele, T.2    Klose, U.3
  • 10
    • 0031866372 scopus 로고    scopus 로고
    • Systematic study of the lactate line-shape in PRESS-localized proton spectroscopy
    • Marshall I, Wild JA. Systematic study of the lactate line-shape in PRESS-localized proton spectroscopy. Magn Reson Med 1998;40:72-78
    • (1998) Magn Reson Med , vol.40 , pp. 72-78
    • Marshall, I.1    Wild, J.A.2
  • 11
    • 0033040399 scopus 로고    scopus 로고
    • Sources of variability in the response of coupled spins to the PRESS sequence and their potential impact on metabolite quantification
    • Thompson RB, Allen PS. Sources of variability in the response of coupled spins to the PRESS sequence and their potential impact on metabolite quantification. Magn Reson Med 1999;41:112-15
    • (1999) Magn Reson Med , vol.41 , pp. 112-115
    • Thompson, R.B.1    Allen, P.S.2
  • 12
    • 0001815374 scopus 로고
    • The effects of frequency-selective RF pulses on J-coupled spin-1/2 systems
    • Slotboom J, Mehlkopf AF, Bovee WMMJ. The effects of frequency-selective RF pulses on J-coupled spin-1/2 systems. J Magn Reson 1994;108:38-50
    • (1994) J Magn Reson , vol.108 , pp. 38-50
    • Slotboom, J.1    Mehlkopf, A.F.2    Bovee, W.M.M.J.3
  • 13
    • 13444278689 scopus 로고    scopus 로고
    • Numerical simulation of PRESS localized MR spectroscopy
    • Maudsley AA, Govindaraju V, Young K, et al. Numerical simulation of PRESS localized MR spectroscopy. J Magn Reson 2005;173:54-63
    • (2005) J Magn Reson , vol.173 , pp. 54-63
    • Maudsley, A.A.1    Govindaraju, V.2    Young, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.