메뉴 건너뛰기




Volumn 6, Issue 1, 2006, Pages 10-29

Hemodynamic analysis and design of a paracorporeal artificial lung device

Author keywords

Artificial lung; Mathematical modeling; Pulmonary circulation; Sheep

Indexed keywords

ARTICLE; ARTIFICIAL LUNG; COMPLIANCE (PHYSICAL); CONTROLLED STUDY; DEVICE; HEART RIGHT VENTRICLE; HEMODYNAMICS; IMPEDANCE; LUNG CIRCULATION; MATHEMATICAL MODEL; PARAMETER; REGRESSION ANALYSIS; SENSITIVITY ANALYSIS; SHEEP;

EID: 33747024082     PISSN: 15678822     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10558-006-9000-x     Document Type: Article
Times cited : (6)

References (35)
  • 1
    • 0000369815 scopus 로고
    • Pulmonary vascular impedance in the dog
    • Bergel DH, and Milnor WR. Pulmonary vascular impedance in the dog. Circ Res 16: 401-415, 1965.
    • (1965) Circ Res , vol.16 , pp. 401-415
    • Bergel, D.H.1    Milnor, W.R.2
  • 2
    • 0033968310 scopus 로고    scopus 로고
    • Hemodynamic effects of attachment modes and device design of a thoracic artificial lung
    • Boschetti F, Perlman CE, Cook KE, and Mockros LF. Hemodynamic effects of attachment modes and device design of a thoracic artificial lung. ASAIO J 46: 42-48, 2000.
    • (2000) ASAIO J , vol.46 , pp. 42-48
    • Boschetti, F.1    Perlman, C.E.2    Cook, K.E.3    Mockros, L.F.4
  • 4
    • 0030105583 scopus 로고    scopus 로고
    • CVODE, a stiff/nonstiff ODE Solver in C
    • Cohen SD and Hindmarsh AC. CVODE, a stiff/nonstiff ODE Solver in C. Computers in Physics 10(2): 138-143, 1996.
    • (1996) Computers in Physics , vol.10 , Issue.2 , pp. 138-143
    • Cohen, S.D.1    Hindmarsh, A.C.2
  • 6
    • 23044488172 scopus 로고    scopus 로고
    • Hemodynamic and gas transfer properties of a compliant thoracic artificial lung
    • Cook KE, Perlman CE, Seipelt R, Backer CL, Mavroudis C, and Mockros LF. Hemodynamic and gas transfer properties of a compliant thoracic artificial lung. ASAIO J 51(4): 404-411, 2005.
    • (2005) ASAIO J , vol.51 , Issue.4 , pp. 404-411
    • Cook, K.E.1    Perlman, C.E.2    Seipelt, R.3    Backer, C.L.4    Mavroudis, C.5    Mockros, L.F.6
  • 10
    • 0034282890 scopus 로고    scopus 로고
    • Hemodynamics on abrupt stoppage of centrifugal pumps during left ventricular assist
    • Kono S, Nishimura K, Nishina T, Akamatsu T, and Komeda M. Hemodynamics on abrupt stoppage of centrifugal pumps during left ventricular assist. ASAIO J 46: 600-603, 2000.
    • (2000) ASAIO J , vol.46 , pp. 600-603
    • Kono, S.1    Nishimura, K.2    Nishina, T.3    Akamatsu, T.4    Komeda, M.5
  • 12
    • 0036081499 scopus 로고    scopus 로고
    • Indexes of diastolic RV function: Load dependence and changes after chronic RV pressure overload in lambs
    • Leeuwenburg BPJ, Steendijk P, Helbing WA, and Baan J. Indexes of diastolic RV function: Load dependence and changes after chronic RV pressure overload in lambs. Am J Physiol Heart Circ Physiol 282: H1350-H1358, 2002.
    • (2002) Am J Physiol Heart Circ Physiol , vol.282
    • Leeuwenburg, B.P.J.1    Steendijk, P.2    Helbing, W.A.3    Baan, J.4
  • 13
    • 0034847756 scopus 로고    scopus 로고
    • Improved right heart function with a compliant inflow artificial lung in series with the pulmonary circulation
    • Lick SD, Zwischenberger JB, Wang D, Deyo DJ, Alpard SK, and Chambers SD. Improved right heart function with a compliant inflow artificial lung in series with the pulmonary circulation. Ann Thorac Surg 72: 899-904, 2001.
    • (2001) Ann Thorac Surg , vol.72 , pp. 899-904
    • Lick, S.D.1    Zwischenberger, J.B.2    Wang, D.3    Deyo, D.J.4    Alpard, S.K.5    Chambers, S.D.6
  • 18
  • 19
    • 0002844887 scopus 로고
    • Pulmonary Hemodynamics
    • In Bergel DH ed New York: Academic Press
    • Milnor WR. Pulmonary Hemodynamics. In Bergel DH ed, Cardiovascular Fluid Dynamics. New York: Academic Press, 1972.
    • (1972) Cardiovascular Fluid Dynamics
    • Milnor, W.R.1
  • 20
    • 0003299906 scopus 로고
    • Pulmonary Circulation
    • In: New York: Oxford University Press
    • Milnor WR. Pulmonary Circulation. In: Cardiovascular Physiology. New York: Oxford University Press, 1990.
    • (1990) Cardiovascular Physiology
    • Milnor, W.R.1
  • 21
    • 0018826031 scopus 로고
    • Aortic input impedance in normal man: Relationship to pressure wave forms
    • Murgo JP, Westerhof N, Giolma JP, and Altobelli SA. Aortic input impedance in normal man: Relationship to pressure wave forms. Circulation 62: 105-116, 1980.
    • (1980) Circulation , vol.62 , pp. 105-116
    • Murgo, J.P.1    Westerhof, N.2    Giolma, J.P.3    Altobelli, S.A.4
  • 22
    • 0021245028 scopus 로고
    • Input impedance of the pulmonary arterial system in normal man
    • Murgo JP and Westerhof N. Input impedance of the pulmonary arterial system in normal man. Circ Res 54: 666-674, 1984.
    • (1984) Circ Res , vol.54 , pp. 666-674
    • Murgo, J.P.1    Westerhof, N.2
  • 23
    • 0003427231 scopus 로고    scopus 로고
    • McDonald's blood flow in arteries: Theoretical, experimental and clinical principles
    • London: Edward Arnold
    • Nichols WW, and O'Rourke MF. McDonald's blood flow in arteries: theoretical, experimental and clinical principles. London: Edward Arnold, 1998.
    • (1998)
    • Nichols, W.W.1    O'Rourke, M.F.2
  • 24
    • 0033672880 scopus 로고    scopus 로고
    • The effect of sudden failure of a rotary blood pump on left ventricular performance in normal and failing hearts
    • Nishida T, Meyns B, Zietkiewicz M, Perek B, Xia Z, Goebel C, Reul H, and Flameng W. The effect of sudden failure of a rotary blood pump on left ventricular performance in normal and failing hearts. Artif Organs 24(11): 893-898, 2000.
    • (2000) Artif Organs , vol.24 , Issue.11 , pp. 893-898
    • Nishida, T.1    Meyns, B.2    Zietkiewicz, M.3    Perek, B.4    Xia, Z.5    Goebel, C.6    Reul, H.7    Flameng, W.8
  • 26
    • 0000628129 scopus 로고
    • Hydraulic input impedance to aorta and pulmonary artery in dogs
    • Patel DJ, de Freitas FM, and Fry DL. Hydraulic input impedance to aorta and pulmonary artery in dogs. J Appl Physiol 18(1): 134-140, 1963.
    • (1963) J Appl Physiol , vol.18 , Issue.1 , pp. 134-140
    • Patel, D.J.1    de Freitas, F.M.2    Fry, D.L.3
  • 28
    • 0020096278 scopus 로고
    • Does normal pulmonary impedance constitute the optimum load for the right ventricle?
    • Piene H and Sund T. Does normal pulmonary impedance constitute the optimum load for the right ventricle? Am J Physiol Heart Circ Physiol 242: H154-H160, 1982.
    • (1982) Am J Physiol Heart Circ Physiol , vol.242
    • Piene, H.1    Sund, T.2
  • 32
    • 0035216144 scopus 로고    scopus 로고
    • Predicting systolic and diastolic aortic blood pressure and stroke volume in the intact sheep
    • Segers P, Steendijk P, Stergiopulos N, and Westerhof N. Predicting systolic and diastolic aortic blood pressure and stroke volume in the intact sheep. J Biomechanics 34: 41-50, 2001.
    • (2001) J Biomechanics , vol.34 , pp. 41-50
    • Segers, P.1    Steendijk, P.2    Stergiopulos, N.3    Westerhof, N.4
  • 33
    • 0033771020 scopus 로고    scopus 로고
    • Unilateral lung edema: Effects on pulmonary gas exchange, hemodynamics, and pulmonary perfusion distribution
    • Slama K, Gesch M, Bock JC, Pietschmann SM, Schaffartzik W, and Pison U. Unilateral lung edema: Effects on pulmonary gas exchange, hemodynamics, and pulmonary perfusion distribution. J Appl Physiol 89: 1513-1521, 2000.
    • (2000) J Appl Physiol , vol.89 , pp. 1513-1521
    • Slama, K.1    Gesch, M.2    Bock, J.C.3    Pietschmann, S.M.4    Schaffartzik, W.5    Pison, U.6
  • 35
    • 0036796247 scopus 로고    scopus 로고
    • The paracorporeal artificial lung improves 5-day outcomes from lethal smoke/burn-induced acute respiratory distress syndrome in sheep
    • Zwischenberger JB, Wang D, Lick SD, Deyo DJ, Alpard SK, Chambers SD. The paracorporeal artificial lung improves 5-day outcomes from lethal smoke/ burn-induced acute respiratory distress syndrome in sheep. Ann Thorac Surg 74: 1011-1018, 2002.
    • (2002) Ann Thorac Surg , vol.74 , pp. 1011-1018
    • Zwischenberger, J.B.1    Wang, D.2    Lick, S.D.3    Deyo, D.J.4    Alpard, S.K.5    Chambers, S.D.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.