메뉴 건너뛰기




Volumn 178, Issue 7, 2006, Pages 713-720

Partial k-space sampling with zero filling used with phase-contrast flow measurements: In vivo and in vitro validation;Partielle k-raum-auslesung mit null-interpolation bei phasenkontrast- flussmessungen: In-vivo- und in-vitro-validierung

Author keywords

Heart; Hemodynamics flow dynamics; Imaging sequences; MR imaging; Vascular

Indexed keywords

ARTICLE; ASCENDING AORTA; CLINICAL ARTICLE; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; HEART OUTPUT; HEMODYNAMICS; HUMAN; IN VITRO STUDY; IN VIVO STUDY; LAMINAR AIRFLOW; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; PROSPECTIVE STUDY; SAMPLING; STATISTICAL SIGNIFICANCE; VALIDATION PROCESS;

EID: 33746904736     PISSN: 14389029     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-2006-926793     Document Type: Article
Times cited : (2)

References (30)
  • 1
    • 0024551349 scopus 로고
    • Human abdominal aorta: Comparative measurements of blood flow with MR imaging and multigated Doppler US
    • Maier SE, Meier D, Boesiger P et al. Human abdominal aorta: comparative measurements of blood flow with MR imaging and multigated Doppler US. Radiology 1989; 171: 487-492
    • (1989) Radiology , vol.171 , pp. 487-492
    • Maier, S.E.1    Meier, D.2    Boesiger, P.3
  • 2
    • 0020340302 scopus 로고
    • A flow velocity zeugmatographic interface for NMR imaging in humans
    • Moran PR. A flow velocity zeugmatographic interface for NMR imaging in humans. Magn Reson Imaging 1982; 1: 197-203
    • (1982) Magn Reson Imaging , vol.1 , pp. 197-203
    • Moran, P.R.1
  • 3
    • 0021930201 scopus 로고
    • NMR blood flow imaging using multiecho, phase contrast sequences
    • O'Donnell M. NMR blood flow imaging using multiecho, phase contrast sequences. Med Phys 1985; 12: 59-64
    • (1985) Med Phys , vol.12 , pp. 59-64
    • O'Donnell, M.1
  • 4
    • 36149042452 scopus 로고
    • Multi-planar image formation using NMR spin echoes
    • Mansfield P. Multi-planar image formation using NMR spin echoes. J Phys C: Solid State Phys 1977; 10: L55-L58
    • (1977) J Phys C: Solid State Phys , vol.10
    • Mansfield, P.1
  • 5
    • 33746803555 scopus 로고
    • Image formation by induced local interactions: Examples employing nuclear magnetic resonance
    • Lauterbur PC. Image formation by induced local interactions: examples employing nuclear magnetic resonance. Nature 1973; 242: 190-191
    • (1973) Nature , vol.242 , pp. 190-191
    • Lauterbur, P.C.1
  • 6
    • 0032480758 scopus 로고    scopus 로고
    • Guidelines for the management of patients with valvular heart disease: Executive summary. A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on Management of Patients with Valvular Heart Disease)
    • Bonow RO, Carabello B, de Leon Jr AC et al. Guidelines for the management of patients with valvular heart disease: executive summary. A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on Management of Patients with Valvular Heart Disease). Circulation 1998; 98: 1949-1984
    • (1998) Circulation , vol.98 , pp. 1949-1984
    • Bonow, R.O.1    Carabello, B.2    De Leon Jr., A.C.3
  • 7
    • 1642382628 scopus 로고    scopus 로고
    • Biventrikuläre MR-volumetrie und MR-flussmessungen in aorta ascendens und truncus pulmonalis zur quantifizierung von klappeninsuffizienzen
    • Rominger MB, Kluge A, Bachmann GF. Biventrikuläre MR-Volumetrie und MR-Flussmessungen in Aorta ascendens und Truncus pulmonalis zur Quantifizierung von Klappeninsuffizienzen. Fortschr Röntgenstr 2004; 176: 342-349
    • (2004) Fortschr Röntgenstr , vol.176 , pp. 342-349
    • Rominger, M.B.1    Kluge, A.2    Bachmann, G.F.3
  • 8
    • 3042586783 scopus 로고    scopus 로고
    • Erstellung von referenzwerten für die MRT-basierte flussmessung im truncus pulmonalis bei gesunden kindern und jugendlichen
    • Abolmaali ND, Esmaeili A, Feist P et al. Erstellung von Referenzwerten für die MRT-basierte Flussmessung im Truncus pulmonalis bei gesunden Kindern und Jugendlichen. Fortschr Röntgenstr 2004; 176: 837-845
    • (2004) Fortschr Röntgenstr , vol.176 , pp. 837-845
    • Abolmaali, N.D.1    Esmaeili, A.2    Feist, P.3
  • 10
    • 0028122164 scopus 로고
    • Quantification of collateral blood flow in coarctation of the aorta by velocity encoded cine magnetic resonance imaging
    • Steffens JC, Bourne MW, Sakuma H et al. Quantification of collateral blood flow in coarctation of the aorta by velocity encoded cine magnetic resonance imaging. Circulation 1994; 90: 937-943
    • (1994) Circulation , vol.90 , pp. 937-943
    • Steffens, J.C.1    Bourne, M.W.2    Sakuma, H.3
  • 11
    • 0031412992 scopus 로고    scopus 로고
    • MR velocity mapping of tricuspid flow: Correction for through-plane motion
    • Kayser HW, Stoel BC, van der Wall EE et al. MR velocity mapping of tricuspid flow: correction for through-plane motion. J Magn Reson Imaging 1997; 7: 669-673
    • (1997) J Magn Reson Imaging , vol.7 , pp. 669-673
    • Kayser, H.W.1    Stoel, B.C.2    Van Der Wall, E.E.3
  • 12
    • 0029101334 scopus 로고
    • Magnetic resonance imaging assessment of the severity of mitral regurgitation. Comparison with invasive techniques
    • Hundley WG, Li HF, Willard JE et al. Magnetic resonance imaging assessment of the severity of mitral regurgitation. Comparison with invasive techniques. Circulation 1995; 92: 1151-1158
    • (1995) Circulation , vol.92 , pp. 1151-1158
    • Hundley, W.G.1    Li, H.F.2    Willard, J.E.3
  • 13
    • 26044441378 scopus 로고    scopus 로고
    • Applications of phase-contrast flow and velocity imaging in cardiovascular MRI
    • Gatehouse PD, Keegan J, Crowe LA et al. Applications of phase-contrast flow and velocity imaging in cardiovascular MRI. Eur Radiol 2005; 15: 2172-2184
    • (2005) Eur Radiol , vol.15 , pp. 2172-2184
    • Gatehouse, P.D.1    Keegan, J.2    Crowe, L.A.3
  • 14
    • 19644390713 scopus 로고    scopus 로고
    • Anteil des frühen systolischen flussanstiegs am antegrad fließenden gesamtvolumen bei phasenkontrast-flussmessungen in atemanhaltetechnik
    • Kunz RP, Oellig F, Krummenauer F et al. Anteil des frühen systolischen Flussanstiegs am antegrad fließenden Gesamtvolumen bei Phasenkontrast-Flussmessungen in Atemanhaltetechnik. Fortschr Röntgenstr 2005; 177: 637-645
    • (2005) Fortschr Röntgenstr , vol.177 , pp. 637-645
    • Kunz, R.P.1    Oellig, F.2    Krummenauer, F.3
  • 15
    • 0035143845 scopus 로고    scopus 로고
    • Effect of breath holding on blood flow measurement using fast velocity encoded cine MRI
    • Sakuma H, Kawada N, Kubo H et al. Effect of breath holding on blood flow measurement using fast velocity encoded cine MRI. Magn Reson Med 2001; 45: 346-348
    • (2001) Magn Reson Med , vol.45 , pp. 346-348
    • Sakuma, H.1    Kawada, N.2    Kubo, H.3
  • 16
    • 0027216325 scopus 로고
    • Quantitative evaluation of several partial Fourier reconstruction algorithms used in MRI
    • McGibney G, Smith MR, Nichols ST et al. Quantitative evaluation of several partial Fourier reconstruction algorithms used in MRI. Magn Reson Med 1993; 30: 51-59
    • (1993) Magn Reson Med , vol.30 , pp. 51-59
    • McGibney, G.1    Smith, M.R.2    Nichols, S.T.3
  • 17
    • 33746865134 scopus 로고    scopus 로고
    • Evaluation of partial Fourier phase contrast acquisition in velocity measurements
    • Szarf G, Dori Y, Tekes A et al. Evaluation of partial Fourier phase contrast acquisition in velocity measurements. Proc Intl Soc Mag Reson Med 2003; 1657
    • (2003) Proc Intl Soc Mag Reson Med , pp. 1657
    • Szarf, G.1    Dori, Y.2    Tekes, A.3
  • 18
    • 17844403299 scopus 로고    scopus 로고
    • In vitro validation of phase-contrast flow measurements at 3 T in comparison to 1.5 T: Precision, accuracy, and signal-to-noise ratios
    • Lotz J, Doker R, Noeske R et al. In vitro validation of phase-contrast flow measurements at 3 T in comparison to 1.5 T: precision, accuracy, and signal-to-noise ratios. J Magn Reson Imaging 2005; 21: 604-610
    • (2005) J Magn Reson Imaging , vol.21 , pp. 604-610
    • Lotz, J.1    Doker, R.2    Noeske, R.3
  • 19
    • 0023726379 scopus 로고
    • Tissue-mimicking gelatin-agar gels for use in magnetic resonance imaging phantoms
    • Blechinger JC, Madsen EL, Frank GR. Tissue-mimicking gelatin-agar gels for use in magnetic resonance imaging phantoms. Med Phys 1988; 15: 629-636
    • (1988) Med Phys , vol.15 , pp. 629-636
    • Blechinger, J.C.1    Madsen, E.L.2    Frank, G.R.3
  • 20
    • 0141765862 scopus 로고    scopus 로고
    • Rapid left-to-right shunt quantification in children by phase-contrast magnetic resonance imaging combined with sensitivity encoding (SENSE)
    • Beerbaum P, Korperich H, Gieseke J et al. Rapid left-to-right shunt quantification in children by phase-contrast magnetic resonance imaging combined with sensitivity encoding (SENSE). Circulation 2003; 108: 1355-1361
    • (2003) Circulation , vol.108 , pp. 1355-1361
    • Beerbaum, P.1    Korperich, H.2    Gieseke, J.3
  • 21
    • 0036651430 scopus 로고    scopus 로고
    • Quantification of flow dynamics in congenital heart disease: Applications of velocity-encoded cine MR imaging
    • discussion 905-896
    • Varaprasathan GA, Araoz PA, Higgins CB et al. Quantification of flow dynamics in congenital heart disease: applications of velocity-encoded cine MR imaging. Radiographics 2002; 22: 895-905; discussion 905-896
    • (2002) Radiographics , vol.22 , pp. 895-905
    • Varaprasathan, G.A.1    Araoz, P.A.2    Higgins, C.B.3
  • 23
    • 0032605611 scopus 로고    scopus 로고
    • K-space sampling strategies
    • Hennig J. K-space sampling strategies. Eur Radiol 1999; 9: 1020-1031
    • (1999) Eur Radiol , vol.9 , pp. 1020-1031
    • Hennig, J.1
  • 24
  • 25
    • 0036845660 scopus 로고    scopus 로고
    • Fast phase-contrast velocity measurement in the steady state
    • Overall WR, Nishimura DG, Hu BS. Fast phase-contrast velocity measurement in the steady state. Magn Reson Med 2002; 48: 890-898
    • (2002) Magn Reson Med , vol.48 , pp. 890-898
    • Overall, W.R.1    Nishimura, D.G.2    Hu, B.S.3
  • 26
    • 17644368176 scopus 로고    scopus 로고
    • Blood flow quantification in adults by phase-contrast MRI combined with SENSE - A validation study
    • Beerbaum P, Korperich H, Gieseke J et al. Blood flow quantification in adults by phase-contrast MRI combined with SENSE-a validation study. J Cardiovasc Magn Reson 2005; 7: 361-369
    • (2005) J Cardiovasc Magn Reson , vol.7 , pp. 361-369
    • Beerbaum, P.1    Korperich, H.2    Gieseke, J.3
  • 28
    • 30444455906 scopus 로고    scopus 로고
    • Beschleunigung der kardiovaskulären MRT mittels paralleler bildgebung: Grundlagen, praktische aspekte, klinische anwendungen und perspektiven
    • Niendorf T, Sodickson D. Beschleunigung der kardiovaskulären MRT mittels paralleler Bildgebung: Grundlagen, praktische Aspekte, klinische Anwendungen und Perspektiven. Fortschr Röntgenstr 2006; 178: 15-30
    • (2006) Fortschr Röntgenstr , vol.178 , pp. 15-30
    • Niendorf, T.1    Sodickson, D.2
  • 30
    • 0034871769 scopus 로고    scopus 로고
    • Real-time interactive duplex MR measurements: Application in neurovascular imaging
    • Wetzel SG, Lee VS, Tan AG et al. Real-time interactive duplex MR measurements: application in neurovascular imaging. AJR 2001; 177: 703-707
    • (2001) AJR , vol.177 , pp. 703-707
    • Wetzel, S.G.1    Lee, V.S.2    Tan, A.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.