Erratum (DOI:10.1016/j.jala.2006.06.003);Verifying Liquid-Handler Performance for Complex or Nonaqueous Reagents: A New Approach

Author keywords

absorbance per pathlength; calibrated syringes as volume transfer standards; dilution ratio; DMSO; dual dye photometry; liquid class; liquid classes; liquid handler calibration; MVS; volume verification

Indexed keywords

BIOASSAY; CALIBRATION; CONCENTRATION (PROCESS); LIQUIDS; PHOTOMETRY; SYRINGES;

EID: 33746887093     PISSN: 15355535     EISSN: 15402452     Source Type: Journal    
DOI: 10.1016/j.jala.2007.10.002     Document Type: Erratum
Times cited : (12)

References (7)
  • 2
    • 3042694087 scopus 로고    scopus 로고
    • Liquid handling: dispensing reliability
    • Felton M.J. Liquid handling: dispensing reliability. Anal. Chem 75 (2003) 397A-399A
    • (2003) Anal. Chem , vol.75
    • Felton, M.J.1
  • 3
    • 16844377080 scopus 로고    scopus 로고
    • Kalibbrierung des Mikroliterpipetten
    • Romaguera A. Kalibbrierung des Mikroliterpipetten. GIT Labor-Fachzeitschrift 4 (2002) 498-500
    • (2002) GIT Labor-Fachzeitschrift , vol.4 , pp. 498-500
    • Romaguera, A.1
  • 5
    • 16844378996 scopus 로고    scopus 로고
    • Comparison of absorbance and fluorescence methods for determining liquid dispensing precision
    • Peterson J., and Nguyen J. Comparison of absorbance and fluorescence methods for determining liquid dispensing precision. J. Assoc. Lab. Autom 10 (2005) 82-87
    • (2005) J. Assoc. Lab. Autom , vol.10 , pp. 82-87
    • Peterson, J.1    Nguyen, J.2
  • 6
    • 13844296598 scopus 로고    scopus 로고
    • Multichannel verification system (MVS): a dual-dye ratiometric photometry system for performance verification of multichannel liquid delivery devices
    • Bradshaw J.T., Knaide T., Rogers A., and Curtis R.H. Multichannel verification system (MVS): a dual-dye ratiometric photometry system for performance verification of multichannel liquid delivery devices. J. Assoc. Lab. Autom 10 (2005) 35-42
    • (2005) J. Assoc. Lab. Autom , vol.10 , pp. 35-42
    • Bradshaw, J.T.1    Knaide, T.2    Rogers, A.3    Curtis, R.H.4
  • 7
    • 33645945895 scopus 로고    scopus 로고
    • The use of a dual dye photometric calibration method to identify possible sample dilution from an automated multichannel liquid-handling system
    • Dong H., Ouyang Z., Liu J., and Jemal M. The use of a dual dye photometric calibration method to identify possible sample dilution from an automated multichannel liquid-handling system. J. Assoc. Lab. Autom 11 (2006) 60-64
    • (2006) J. Assoc. Lab. Autom , vol.11 , pp. 60-64
    • Dong, H.1    Ouyang, Z.2    Liu, J.3    Jemal, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.