메뉴 건너뛰기




Volumn 45, Issue 1, 1998, Pages 10-18

Heparin and protamine titration do not improve haemostasis in cardiac surgical patients

Author keywords

[No Author keywords available]

Indexed keywords

HEMOCHRON; HEPARIN; PROTAMINE; UNCLASSIFIED DRUG;

EID: 0031918371     PISSN: 0832610X     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF03011985     Document Type: Article
Times cited : (59)

References (26)
  • 1
    • 0016808488 scopus 로고
    • Heparin therapy during extracorporeal circulation. I. Problems inherent in existing heparin protocols
    • Bull BS, Korpman RA, Huse WM, Briggs BD. Heparin therapy during extracorporeal circulation. I. Problems inherent in existing heparin protocols. J Thorac Cardiovasc Surg 1975; 69: 674-84.
    • (1975) J Thorac Cardiovasc Surg , vol.69 , pp. 674-684
    • Bull, B.S.1    Korpman, R.A.2    Huse, W.M.3    Briggs, B.D.4
  • 2
    • 25344455927 scopus 로고
    • Heparin sensitivity: Influence of patient age, source of heparin and previous treatment
    • Jobes DR, Aitken GL, Steven JM, Nicolson SC. Heparin sensitivity: influence of patient age, source of heparin and previous treatment. Anesthesiology 1993; 79: A89.
    • (1993) Anesthesiology , vol.79
    • Jobes, D.R.1    Aitken, G.L.2    Steven, J.M.3    Nicolson, S.C.4
  • 3
    • 0030028375 scopus 로고    scopus 로고
    • Factors associated with excessive post-operative blood loss and hemostatic transfusion requirements: A multivariate analysis in cardiac surgical patients
    • Despotis GJ, Filos KS, Zoys TN, Hogue CW Jr, Spitznagel E, Lappas DG. Factors associated with excessive post-operative blood loss and hemostatic transfusion requirements: a multivariate analysis in cardiac surgical patients. Anesth Analg 1996; 82: 13-21.
    • (1996) Anesth Analg , vol.82 , pp. 13-21
    • Despotis, G.J.1    Filos, K.S.2    Zoys, T.N.3    Hogue Jr., C.W.4    Spitznagel, E.5    Lappas, D.G.6
  • 4
    • 0025254425 scopus 로고
    • Heparin dosing and monitoring for cardiopulmonary bypass. A comparison of techniques with measurement of subclinical plasma coagulation
    • Gravlee GP, Haddon WS, Rothberger HK, et al. Heparin dosing and monitoring for cardiopulmonary bypass. A comparison of techniques with measurement of subclinical plasma coagulation. J Thorac Cardiovasc Surg 1990; 99: 518-27.
    • (1990) J Thorac Cardiovasc Surg , vol.99 , pp. 518-527
    • Gravlee, G.P.1    Haddon, W.S.2    Rothberger, H.K.3
  • 5
    • 0021949898 scopus 로고
    • Protamine: A review of its toxicity
    • Horrow JC. Protamine: a review of its toxicity. Anesth Analg 1985; 64: 348-61.
    • (1985) Anesth Analg , vol.64 , pp. 348-361
    • Horrow, J.C.1
  • 6
    • 0028037790 scopus 로고
    • At high heparin concentrations, protamine concentrations which reverse heparin anticoagulant effects are insufficient to reverse heparin anti-platelet effects
    • Carr ME Jr, Carr SL. At high heparin concentrations, protamine concentrations which reverse heparin anticoagulant effects are insufficient to reverse heparin anti-platelet effects. Thromb Res 1994; 75: 617-30.
    • (1994) Thromb Res , vol.75 , pp. 617-630
    • Carr Jr., M.E.1    Carr, S.L.2
  • 8
    • 0018135359 scopus 로고
    • Adequate anticoagulation during cardiopulmonary bypass determined by activated clotting time and the appearance of fibrin monomer
    • Young JA, Kisker CT. Doty DB. Adequate anticoagulation during cardiopulmonary bypass determined by activated clotting time and the appearance of fibrin monomer. Ann Thorac Surg 1978; 26: 231-40.
    • (1978) Ann Thorac Surg , vol.26 , pp. 231-240
    • Young, J.A.1    Kisker, C.T.2    Doty, D.B.3
  • 10
    • 0027426380 scopus 로고
    • Comparison of bedside coagulation monitor-ing tests with standard laboratory tests in patients after cardiac surgery
    • Reich DL, Yanakakis MJ, Vela-Cantos FP, DePerio M, Jacobs E. Comparison of bedside coagulation monitor-ing tests with standard laboratory tests in patients after cardiac surgery. Anesth Analg 1993; 77: 673-9.
    • (1993) Anesth Analg , vol.77 , pp. 673-679
    • Reich, D.L.1    Yanakakis, M.J.2    Vela-Cantos, F.P.3    DePerio, M.4    Jacobs, E.5
  • 11
    • 85036598760 scopus 로고    scopus 로고
    • International Technidyne Inc., Edison, NJ: Thrombin Time and Heparin Thrombin Time, Rev 1/94
    • Package insert, Hemochron® Whole Blood Coagulation System, International Technidyne Inc., Edison, NJ: Thrombin Time and Heparin Thrombin Time, Rev 1/94.
    • Package Insert, Hemochron® Whole Blood Coagulation System
  • 12
    • 0029075636 scopus 로고
    • Increased accuracy and precision of heparin and protamine dosing reduces blood loss and transfusion in patients undergoing primary cardiac operations
    • Jobes DR, Aitken GL, Shaffer GW. Increased accuracy and precision of heparin and protamine dosing reduces blood loss and transfusion in patients undergoing primary cardiac operations. J Thorac Cardiovasc Surg 1995; 110: 36-45.
    • (1995) J Thorac Cardiovasc Surg , vol.110 , pp. 36-45
    • Jobes, D.R.1    Aitken, G.L.2    Shaffer, G.W.3
  • 13
    • 0029052424 scopus 로고
    • The impact of heparin concentration and activated clotting time monitoring on blood conservation
    • Despotis GJ, Joist JH, Hogue CW Jr, et al. The impact of heparin concentration and activated clotting time monitoring on blood conservation. J Thorac Cardiovasc Surg 1995; 110: 46-54.
    • (1995) J Thorac Cardiovasc Surg , vol.110 , pp. 46-54
    • Despotis, G.J.1    Joist, J.H.2    Hogue Jr., C.W.3
  • 14
    • 0017230999 scopus 로고
    • Successful use of a reduced dose of protamine after cardiopulmonary bypass
    • Guffin AV, Dunbar RW, Kaplan JA, Bland JW Jr. Successful use of a reduced dose of protamine after cardiopulmonary bypass. Anesth Analg 1976; 55: 110-3.
    • (1976) Anesth Analg , vol.55 , pp. 110-113
    • Guffin, A.V.1    Dunbar, R.W.2    Kaplan, J.A.3    Bland Jr., J.W.4
  • 15
    • 0026040646 scopus 로고
    • Protamine - the need to determine the dose. Comparison of a simple protamine titration method with an empirical dose regimen for reversal of heparinisation following cardiopulmonary bypass
    • Keeler JF, Shah MV, Hansbro SD. Protamine - the need to determine the dose. Comparison of a simple protamine titration method with an empirical dose regimen for reversal of heparinisation following cardiopulmonary bypass. Anaesthesia 1991; 46: 925-8.
    • (1991) Anaesthesia , vol.46 , pp. 925-928
    • Keeler, J.F.1    Shah, M.V.2    Hansbro, S.D.3
  • 16
    • 0028025445 scopus 로고
    • Heparin-protamine mismatch. A controllable factor in bleeding after open heart surgery
    • DeLaria GA, Tyner JJ, Hayes CL, Armstrong BW. Heparin-protamine mismatch. A controllable factor in bleeding after open heart surgery. Arch Surg 1994; 129: 945-51.
    • (1994) Arch Surg , vol.129 , pp. 945-951
    • DeLaria, G.A.1    Tyner, J.J.2    Hayes, C.L.3    Armstrong, B.W.4
  • 17
    • 0027961049 scopus 로고
    • Comparison of activated coagulation time and whole blood heparin measurements with laboratory plasma anti-Xa heparin concentration in patients having cardiac operations
    • Despotis GJ, Summerfield AL, Joist JH, et al. Comparison of activated coagulation time and whole blood heparin measurements with laboratory plasma anti-Xa heparin concentration in patients having cardiac operations. J Thorac Cardiovasc Surg 1994; 108: 1076-82.
    • (1994) J Thorac Cardiovasc Surg , vol.108 , pp. 1076-1082
    • Despotis, G.J.1    Summerfield, A.L.2    Joist, J.H.3
  • 18
    • 0029781058 scopus 로고    scopus 로고
    • Measurement of heparin concentration in whole blood with the Hepcon/HMS device does not agree with laboratory determination of plasma heparin concentration using a chromogenic substrate for activated factor X
    • Hardy J-F, Bélisle S. Robitaille D, Perrault J, Roy M, Gagnon L. Measurement of heparin concentration in whole blood with the Hepcon/HMS device does not agree with laboratory determination of plasma heparin concentration using a chromogenic substrate for activated factor X. J Thorac Cardiovasc Surg 1996; 112: 154-61.
    • (1996) J Thorac Cardiovasc Surg , vol.112 , pp. 154-161
    • Hardy, J.-F.1    Bélisle, S.2    Robitaille, D.3    Perrault, J.4    Roy, M.5    Gagnon, L.6
  • 20
    • 0026510604 scopus 로고
    • Heparin management protocol for cardiopulmonary bypass influences postoperative heparin rebound but not bleeding
    • Gravlee GP, Rogers AT, Dudes LM, et al. Heparin management protocol for cardiopulmonary bypass influences postoperative heparin rebound but not bleeding. Anesthesiology 1992; 76: 393-401.
    • (1992) Anesthesiology , vol.76 , pp. 393-401
    • Gravlee, G.P.1    Rogers, A.T.2    Dudes, L.M.3
  • 21
    • 0027310437 scopus 로고
    • The platelet function defect of cardiopulmonary bypass
    • Kestin AS, Valeri CR, Khuri SF, et al. The platelet function defect of cardiopulmonary bypass. Blood 1993; 82: 107-17.
    • (1993) Blood , vol.82 , pp. 107-117
    • Kestin, A.S.1    Valeri, C.R.2    Khuri, S.F.3
  • 22
    • 0028809946 scopus 로고
    • Heparin causes platelet dysfunction and induces fibrinolysis before cardiopulmonary bypass
    • Khuri SF, Valeri CR, Loscalzo J, et al. Heparin causes platelet dysfunction and induces fibrinolysis before cardiopulmonary bypass. Ann Thorac Surg 1995; 60: 1008-14.
    • (1995) Ann Thorac Surg , vol.60 , pp. 1008-1014
    • Khuri, S.F.1    Valeri, C.R.2    Loscalzo, J.3
  • 25
    • 0026689814 scopus 로고
    • Hematologic changes during and after cardiopulmonary bypass and their relationship to the bleeding time and nonsurgical blood loss
    • Khuri SF, Wolfe JA, Josa M, et al. Hematologic changes during and after cardiopulmonary bypass and their relationship to the bleeding time and nonsurgical blood loss. J Thorac Cardiovasc Surg 1992; 104: 94-107.
    • (1992) J Thorac Cardiovasc Surg , vol.104 , pp. 94-107
    • Khuri, S.F.1    Wolfe, J.A.2    Josa, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.