메뉴 건너뛰기




Volumn 56, Issue 2, 2006, Pages 432-438

Rapid cardiac-output measurement with ungated spiral phase contrast

Author keywords

Cardiac output; Fast imaging; Flow; Phase contrast; Quantification; Spiral

Indexed keywords

HEMODYNAMICS;

EID: 33746670556     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.20970     Document Type: Article
Times cited : (10)

References (20)
  • 2
    • 12244310182 scopus 로고    scopus 로고
    • Rapid measurement of time-averaged blood flow using ungated spiral phase-contrast
    • Park JB, Olcott EW, Nishimura DG. Rapid measurement of time-averaged blood flow using ungated spiral phase-contrast. Magn Reson Med 2003;49:322-328.
    • (2003) Magn Reson Med , vol.49 , pp. 322-328
    • Park, J.B.1    Olcott, E.W.2    Nishimura, D.G.3
  • 6
    • 21244461569 scopus 로고    scopus 로고
    • Single-breathhold, four-dimensional, quantitative assessment of LV and RV function using triggered, real-time, steady-state free precession MRI in heart failure patients
    • Narayan G, Nayak K, Pauly J, Hu B. Single-breathhold, four-dimensional, quantitative assessment of LV and RV function using triggered, real-time, steady-state free precession MRI in heart failure patients. J Magn Reson Imaging 2005;22:59-66.
    • (2005) J Magn Reson Imaging , vol.22 , pp. 59-66
    • Narayan, G.1    Nayak, K.2    Pauly, J.3    Hu, B.4
  • 7
    • 0037225732 scopus 로고    scopus 로고
    • Triggered real-time MRI and cardiac applications
    • Nayak KS, Hu BS. Triggered real-time MRI and cardiac applications. Magn Reson Med 2003;49:188-192.
    • (2003) Magn Reson Med , vol.49 , pp. 188-192
    • Nayak, K.S.1    Hu, B.S.2
  • 8
    • 0022686199 scopus 로고
    • High-speed spiral-scan echo planar NMR imaging-I
    • Ahn CB, Kim JH, Cho ZH. High-speed spiral-scan echo planar NMR imaging-I. IEEE Trans Med Imaging 1986;MI-5:2-7.
    • (1986) IEEE Trans Med Imaging , vol.MI-5 , pp. 2-7
    • Ahn, C.B.1    Kim, J.H.2    Cho, Z.H.3
  • 10
    • 0028830695 scopus 로고
    • The voxel sensitivity function in Fourier transform imaging: Applications to magnetic resonance angiography
    • Parker DL, Du YP, Davis WL. The voxel sensitivity function in Fourier transform imaging: applications to magnetic resonance angiography. Magn Reson Med 1995;33:156-162.
    • (1995) Magn Reson Med , vol.33 , pp. 156-162
    • Parker, D.L.1    Du, Y.P.2    Davis, W.L.3
  • 11
    • 0033037618 scopus 로고    scopus 로고
    • MR phase-contrast flow measurement with limited spatial resolution in small vessels: Value of model-based image analysis
    • Hoogeveen RM, Bakker CJ, Viergever MA. MR phase-contrast flow measurement with limited spatial resolution in small vessels: value of model-based image analysis. Magn Reson Med 1999;41:520-528.
    • (1999) Magn Reson Med , vol.41 , pp. 520-528
    • Hoogeveen, R.M.1    Bakker, C.J.2    Viergever, M.A.3
  • 12
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 16
    • 0028509583 scopus 로고
    • Effects of intravoxel velocity distributions on the accuracy of the phase-mapping method in phase-contrast MR angiography
    • Hamilton CA, Moran PR, Santago 2nd P, Rajala SA. Effects of intravoxel velocity distributions on the accuracy of the phase-mapping method in phase-contrast MR angiography. J Magn Reson Imaging 1994;4:752-755.
    • (1994) J Magn Reson Imaging , vol.4 , pp. 752-755
    • Hamilton, C.A.1    Moran, P.R.2    Santago II, P.3    Rajala, S.A.4
  • 17
    • 0027254511 scopus 로고
    • Analysis of systematic and random error in MR volumetric flow measurements
    • Wolf RL, Ehman RL, Riederer SJ, Rossman PJ. Analysis of systematic and random error in MR volumetric flow measurements. Magn Reson Med 1993;30:82-91.
    • (1993) Magn Reson Med , vol.30 , pp. 82-91
    • Wolf, R.L.1    Ehman, R.L.2    Riederer, S.J.3    Rossman, P.J.4
  • 19
    • 2142694343 scopus 로고    scopus 로고
    • Flow volume and shunt quantification in pediatric congenital heart disease by real-time magnetic resonance velocity mapping: A validation study
    • Korperich H, Gieseke J, Barth P, Hoogeveen R, Esdorn H, Peterschroder A, Meyer H, Beerbaum P. Flow volume and shunt quantification in pediatric congenital heart disease by real-time magnetic resonance velocity mapping: a validation study. Circulation 2004;109: 1987-1993.
    • (2004) Circulation , vol.109 , pp. 1987-1993
    • Korperich, H.1    Gieseke, J.2    Barth, P.3    Hoogeveen, R.4    Esdorn, H.5    Peterschroder, A.6    Meyer, H.7    Beerbaum, P.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.