메뉴 건너뛰기




Volumn 27, Issue 9, 2006, Pages 829-838

A theoretical study on magnetic induction frequency dependence of phase shift in oedema and haematoma

Author keywords

Induction; Magnetic; Phase shift; Shift; Spectroscopy

Indexed keywords

ELECTROMAGNETIC INDUCTION; FUNCTIONS; HISTOLOGY; MUSCLE; TUMORS;

EID: 33746581693     PISSN: 09673334     EISSN: 13616579     Source Type: Journal    
DOI: 10.1088/0967-3334/27/9/006     Document Type: Article
Times cited : (29)

References (28)
  • 1
    • 0027398352 scopus 로고
    • A feasibility study of in vivo electromagnetic imaging
    • Al-Zeiback and Saunders N H 1993 A feasibility study of in vivo electromagnetic imaging Phys. Med. Biol. 38 151-60
    • (1993) Phys. Med. Biol. , vol.38 , Issue.1 , pp. 151-160
    • Al-Zeiback1    Saunders, N.H.2
  • 5
    • 0029957193 scopus 로고    scopus 로고
    • The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues
    • Gabriel S, Lau R W and Gabriel C 1996 The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues Phys. Med. Biol. 41 2271-93
    • (1996) Phys. Med. Biol. , vol.41 , Issue.11 , pp. 2271-2293
    • Gabriel, S.1    Lau, R.W.2    Gabriel, C.3
  • 6
    • 0036590104 scopus 로고    scopus 로고
    • Assessment of human brain water content by cerebral bioelectrical impedance analysis: A new technique and its application to cerebral pathological conditions
    • Grasso G, Alafaci C, Passalaqcua M, Morabito A, Buemi M, Salpietro F M and Tomasello F 2002 Assessment of human brain water content by cerebral bioelectrical impedance analysis: a new technique and its application to cerebral pathological conditions Neurosurgery 50 1064-72
    • (2002) Neurosurgery , vol.50 , pp. 1064-1072
    • Grasso, G.1    Alafaci, C.2    Passalaqcua, M.3    Morabito, A.4    Buemi, M.5    Salpietro, F.M.6    Tomasello, F.7
  • 7
    • 0035422248 scopus 로고    scopus 로고
    • Magnetic induction tomography
    • Griffiths H 2001 Magnetic induction tomography Meas. Sci. Technol. 12 1126-31
    • (2001) Meas. Sci. Technol. , vol.12 , Issue.8 , pp. 1126-1131
    • Griffiths, H.1
  • 8
    • 0032988044 scopus 로고    scopus 로고
    • Magnetic induction tomography-a measuring system for biological materials
    • Griffiths H, Steward W R and Gough W 1999 Magnetic induction tomography-a measuring system for biological materials Ann. NY Acad. Sci. 873 335-45
    • (1999) Ann. NY Acad. Sci. , vol.873 , pp. 335-345
    • Griffiths, H.1    Steward, W.R.2    Gough, W.3
  • 9
    • 12244252258 scopus 로고    scopus 로고
    • Monitoring the permeability edema of ventilator-associated lung injury
    • Groeneveld A B J, Plotz F B and van Genderingen H R 2005 Monitoring the permeability edema of ventilator-associated lung injury Crit. Care Med. 33 250-2
    • (2005) Crit. Care Med. , vol.33 , Issue.1 , pp. 250-252
    • Groeneveld, A.B.J.1    Plotz, F.B.2    Van Genderingen, H.R.3
  • 10
  • 11
    • 0033049822 scopus 로고    scopus 로고
    • Assessment and calibration of a low-frequency system for electrical impedance tomography (EIT), optimized for use in imaging brain function in ambulant human subjects
    • Holder D S, Gonzalez-Correa C A, Tidswell T, Gibson A, Gusick G and Bayford R H 1999 Assessment and calibration of a low-frequency system for electrical impedance tomography (EIT), optimized for use in imaging brain function in ambulant human subjects Ann. NY Acad. Sci. 873 512-9
    • (1999) Ann. NY Acad. Sci. , vol.873 , pp. 512-519
    • Holder, D.S.1    Gonzalez-Correa, C.A.2    Tidswell, T.3    Gibson, A.4    Gusick, G.5    Bayford, R.H.6
  • 12
    • 0032820259 scopus 로고    scopus 로고
    • Correlation of permittivity and water content during cerebral edema
    • Kao H P, Cardoso E R and Shwedyk E 1999 Correlation of permittivity and water content during cerebral edema IEEE Trans. Biomed. Eng. 46 1121-8
    • (1999) IEEE Trans. Biomed. Eng. , vol.46 , Issue.9 , pp. 1121-1128
    • Kao, H.P.1    Cardoso, E.R.2    Shwedyk, E.3
  • 14
    • 0033025802 scopus 로고    scopus 로고
    • Progress in realization of magnetic induction tomography
    • Korjenevsky A V and Cherepenin V A 1999 Progress in realization of magnetic induction tomography Ann. NY Acad. Sci. 873 346-52
    • (1999) Ann. NY Acad. Sci. , vol.873 , pp. 346-352
    • Korjenevsky, A.V.1    Cherepenin, V.A.2
  • 15
    • 0020129783 scopus 로고
    • Microwave imaging of cerebral edema
    • Lin J C and Clarke M J 1982 Microwave imaging of cerebral edema Proc. IEEE 70 523-4
    • (1982) Proc. IEEE , vol.70 , Issue.5 , pp. 523-524
    • Lin, J.C.1    Clarke, M.J.2
  • 16
    • 0022352623 scopus 로고
    • Pathophysiology of pulmonary edema
    • Matthay M A 1985 Pathophysiology of pulmonary edema Clin. Chest Med. 6 301-14
    • (1985) Clin. Chest Med. , vol.6 , pp. 301-314
    • Matthay, M.A.1
  • 17
    • 1342332813 scopus 로고    scopus 로고
    • Detection of brain oedema using magnetic induction tomography: A feasibility study of likely sensitivity and detectability
    • Merwa R, Hollaus K, Biró O and Scharfetter H 2004 Detection of brain oedema using magnetic induction tomography: a feasibility study of likely sensitivity and detectability Physiol. Meas. 25 347-57
    • (2004) Physiol. Meas. , vol.25 , Issue.1 , pp. 347-357
    • Merwa, R.1    Hollaus, K.2    Biró, O.3    Scharfetter, H.4
  • 18
    • 0036797775 scopus 로고    scopus 로고
    • +) concentrations after cerebral ischemia and the effects of mild cerebral hypothermia
    • +) concentrations after cerebral ischemia and the effects of mild cerebral hypothermia J. Neurotrauma 19 1261-70
    • (2002) J. Neurotrauma , vol.19 , Issue.10 , pp. 1261-1270
    • Mori, K.1    Miyazaki, M.2    Iwase, H.3    Maeda, M.4
  • 19
    • 0031007803 scopus 로고    scopus 로고
    • Bioelectrical impedance techniques in medicine
    • Morucci J P and Rigaud B 1996 Bioelectrical impedance techniques in medicine Crit. Rev. Biomed. Eng. 24 655-77
    • (1996) Crit. Rev. Biomed. Eng. , vol.24 , Issue.4-6 , pp. 655-677
    • Morucci, J.P.1    Rigaud, B.2
  • 20
    • 0027360406 scopus 로고
    • Contactless impedance measurement by magnetic induction-a possible method for investigation of brain impedance
    • Netz J E, Forner E and Haagemann S 1993 Contactless impedance measurement by magnetic induction-a possible method for investigation of brain impedance Physiol. Meas. 14 463-71
    • (1993) Physiol. Meas. , vol.14 , Issue.4 , pp. 463-471
    • Netz, J.E.1    Forner, E.2    Haagemann, S.3
  • 23
    • 0043165089 scopus 로고    scopus 로고
    • Biological tissue characterization by magnetic induction spectroscopy (MIS): Requirements and limitations
    • Scharfetter H, Casãas R and Rosell J 2003 Biological tissue characterization by magnetic induction spectroscopy (MIS): requirements and limitations IEEE Trans. Biomed. Eng. 50 870-80
    • (2003) IEEE Trans. Biomed. Eng. , vol.50 , Issue.7 , pp. 870-880
    • Scharfetter, H.1    Casãas, R.2    Rosell, J.3
  • 25
    • 0019203748 scopus 로고
    • The UHF and microwave dielectric properties of normal and tumor tissues: Variations in dielectric properties with tissue water content
    • Schepps J L and Foster K R 1980 The UHF and microwave dielectric properties of normal and tumor tissues: variations in dielectric properties with tissue water content Phys. Med. Biol. 25 1149-59
    • (1980) Phys. Med. Biol. , vol.25 , Issue.6 , pp. 1149-1159
    • Schepps, J.L.1    Foster, K.R.2
  • 26
    • 54949152106 scopus 로고
    • Electrical properties of tissue and cell suspensions
    • Schwan H P 1957 Electrical properties of tissue and cell suspensions Adv. Biol. Med. Phys. 5 147-209
    • (1957) Adv. Biol. Med. Phys. , vol.5 , pp. 147-209
    • Schwan, H.P.1
  • 27
    • 0014340443 scopus 로고
    • Electrodeless measurements of the effective resistivity of the human torso and head by magnetic induction
    • Tarjan F P and McFee R 1968 Electrodeless measurements of the effective resistivity of the human torso and head by magnetic induction IEEE Trans. Biomed. Eng. 15 266-78
    • (1968) IEEE Trans. Biomed. Eng. , vol.15 , pp. 266-278
    • Tarjan, F.P.1    McFee, R.2
  • 28
    • 73849171822 scopus 로고
    • Bio-electrical properties of tissue impedance measurements
    • Thomasset A 1962 Bio-electrical properties of tissue impedance measurements Lyon. Med. 207 107-18
    • (1962) Lyon. Med. , vol.207 , pp. 107-118
    • Thomasset, A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.