메뉴 건너뛰기




Volumn 29, Issue 11, 2004, Pages 1203-1207

Biomechanical comparison of kyphoplasty with different bone cements

Author keywords

tricalcium phosphate cement; Kyphoplasty; Polymethylmethacrylate

Indexed keywords

ALPHA TRICALCIUM PHOSPHATE; BONE CEMENT; CALCIUM PHOSPHATE; POLY(METHYL METHACRYLATE); UNCLASSIFIED DRUG;

EID: 2542500514     PISSN: 03622436     EISSN: None     Source Type: Journal    
DOI: 10.1097/00007632-200406010-00009     Document Type: Article
Times cited : (84)

References (30)
  • 1
    • 0035110042 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty: A developing standard of care for vertebral compression fractures
    • Mathis JM, Barr JD, Belkoff SM, et al. Percutaneous vertebroplasty: a developing standard of care for vertebral compression fractures. AJNR Am J Neuroradiol. 2001;22:373-381.
    • (2001) AJNR Am J Neuroradiol , vol.22 , pp. 373-381
    • Mathis, J.M.1    Barr, J.D.2    Belkoff, S.M.3
  • 2
    • 0034655411 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty for pain relief and spinal stabilization
    • Barr JD, Barr MS, Lemley TJ, et al. Percutaneous vertebroplasty for pain relief and spinal stabilization. Spine. 2000;25:923-928.
    • (2000) Spine , vol.25 , pp. 923-928
    • Barr, J.D.1    Barr, M.S.2    Lemley, T.J.3
  • 3
    • 0032846650 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty in the treatment of osteoporotic vertebral compression fractures: An open prospective study
    • Cortet B, Cotten A, Boutry N, et al. Percutaneous vertebroplasty in the treatment of osteoporotic vertebral compression fractures: an open prospective study. J Rheumatol. 1999;26:2222-2228.
    • (1999) J Rheumatol , vol.26 , pp. 2222-2228
    • Cortet, B.1    Cotten, A.2    Boutry, N.3
  • 4
    • 0032015176 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty: State of the art
    • Cotten A, Boutry N, Cortet B, et al. Percutaneous vertebroplasty: state of the art. Radiographics. 1998;18:311-323.
    • (1998) Radiographics , vol.18 , pp. 311-323
    • Cotten, A.1    Boutry, N.2    Cortet, B.3
  • 5
    • 0043165850 scopus 로고
    • Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty
    • Galibert P, Deramond H, Rosat P, et al. [Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty]. Neurochirurgie. 1987;33:166-168.
    • (1987) Neurochirurgie , vol.33 , pp. 166-168
    • Galibert, P.1    Deramond, H.2    Rosat, P.3
  • 6
    • 0035879322 scopus 로고    scopus 로고
    • Initial outcome and efficacy of "kyphoplasty " in the treatment of painful osteoporotic vertebral compression fractures
    • Lieberman IH, Dudeney S, Reinhardt MK, et al. Initial outcome and efficacy of "kyphoplasty " in the treatment of painful osteoporotic vertebral compression fractures. Spine. 2001;26:1631-1638.
    • (2001) Spine , vol.26 , pp. 1631-1638
    • Lieberman, I.H.1    Dudeney, S.2    Reinhardt, M.K.3
  • 7
    • 0032807670 scopus 로고    scopus 로고
    • Temperature elevation caused by bone cement polymerization during vertebroplasty
    • Deramond H, Wright NT, Belkoff SM. Temperature elevation caused by bone cement polymerization during vertebroplasty. Bone. 1999;25(suppl): 17-21.
    • (1999) Bone , vol.25 , Issue.SUPPL. , pp. 17-21
    • Deramond, H.1    Wright, N.T.2    Belkoff, S.M.3
  • 8
    • 0031431778 scopus 로고    scopus 로고
    • Future directions: Augmentation of osteoporotic vertebral bodies
    • Bostrom MPG, Lane JM. Future directions: augmentation of osteoporotic vertebral bodies. Spine. 1997;22(suppl):38-42.
    • (1997) Spine , vol.22 , Issue.SUPPL. , pp. 38-42
    • Bostrom, M.P.G.1    Lane, J.M.2
  • 9
    • 0038638437 scopus 로고    scopus 로고
    • Temperature measurement during polymerization of polymethylmethacrylate cement used for vertebroplasty
    • Belkoff SM, Molloy S. Temperature measurement during polymerization of polymethylmethacrylate cement used for vertebroplasty. Spine. 2003;28: 1555-1559.
    • (2003) Spine , vol.28 , pp. 1555-1559
    • Belkoff, S.M.1    Molloy, S.2
  • 10
    • 0034193728 scopus 로고    scopus 로고
    • Biomechanical evaluation of a new bone cement for use in vertebroplasty
    • Belkoff SM, Mathis JM, Erbe EM, et al. Biomechanical evaluation of a new bone cement for use in vertebroplasty. Spine. 2000;25:1061-1064.
    • (2000) Spine , vol.25 , pp. 1061-1064
    • Belkoff, S.M.1    Mathis, J.M.2    Erbe, E.M.3
  • 11
    • 0032810055 scopus 로고    scopus 로고
    • The use of an injectable, biodegradable calcium phosphate bone substitute for the prophylactic augmentation of osteoporotic vertebrae and the management of vertebral compression fractures
    • Bai B, Jazrawi LM, Kummer FJ, et al. The use of an injectable, biodegradable calcium phosphate bone substitute for the prophylactic augmentation of osteoporotic vertebrae and the management of vertebral compression fractures. Spine. 1999;24:1521-1526.
    • (1999) Spine , vol.24 , pp. 1521-1526
    • Bai, B.1    Jazrawi, L.M.2    Kummer, F.J.3
  • 12
    • 0032521419 scopus 로고    scopus 로고
    • Reinforcement of thoracolumbar burst fractures with calcium phosphate cement: A biomechanical study
    • Mermelstein LE, McLain RF, Yerby SA. Reinforcement of thoracolumbar burst fractures with calcium phosphate cement: a biomechanical study. Spine. 1998;23:664-670.
    • (1998) Spine , vol.23 , pp. 664-670
    • Mermelstein, L.E.1    McLain, R.F.2    Yerby, S.A.3
  • 13
    • 0035054442 scopus 로고    scopus 로고
    • Augmentation of mechanical properties in osteoporotic vertebral bones: A biomechanical investigation of vertebroplasty efficacy with different bone cements
    • Heini PF, Berlemann U, Kaufmann M, et al. Augmentation of mechanical properties in osteoporotic vertebral bones: a biomechanical investigation of vertebroplasty efficacy with different bone cements. Eur Spine J. 2001;10: 164-171.
    • (2001) Eur Spine J , vol.10 , pp. 164-171
    • Heini, P.F.1    Berlemann, U.2    Kaufmann, M.3
  • 14
    • 0035879286 scopus 로고    scopus 로고
    • An ex vivo biomechanical evaluation of a hydroxyapatite cement for use with vertebroplasty
    • Belkoff SM, Mathis JM, Jasper LE, et al. An ex vivo biomechanical evaluation of a hydroxyapatite cement for use with vertebroplasty. Spine. 2001;26: 1542-1546.
    • (2001) Spine , vol.26 , pp. 1542-1546
    • Belkoff, S.M.1    Mathis, J.M.2    Jasper, L.E.3
  • 15
    • 0036846092 scopus 로고    scopus 로고
    • An ex vivo biomechanical comparison of hydroxyapatite and polymethylmethacrylate cements for use with vertebroplasty
    • Belkoff SM, Mathis JM, Jasper LE. An ex vivo biomechanical comparison of hydroxyapatite and polymethylmethacrylate cements for use with vertebroplasty. AJNR Am J Neuroradiol. 2002;23:1647-1651.
    • (2002) AJNR Am J Neuroradiol , vol.23 , pp. 1647-1651
    • Belkoff, S.M.1    Mathis, J.M.2    Jasper, L.E.3
  • 16
    • 0001098678 scopus 로고    scopus 로고
    • Calcium phosphate cement injection for osteoporotic vertebral fracture
    • Yamamoto H, Shibata T, Ikeuchi M. Calcium phosphate cement injection for osteoporotic vertebral fracture. Rinsyou Seikeigeka. 1998;35:435-442.
    • (1998) Rinsyou Seikeigeka , vol.35 , pp. 435-442
    • Yamamoto, H.1    Shibata, T.2    Ikeuchi, M.3
  • 17
    • 0034951131 scopus 로고    scopus 로고
    • An ex vivo biomechanical evaluation of a hydroxyapatite cement for use with kyphoplasty
    • Belkoff SM, Mathis JM, Deramond H, et al. An ex vivo biomechanical evaluation of a hydroxyapatite cement for use with kyphoplasty. AJNR Am J Neuroradiol. 2001;22:1212-1216.
    • (2001) AJNR Am J Neuroradiol , vol.22 , pp. 1212-1216
    • Belkoff, S.M.1    Mathis, J.M.2    Deramond, H.3
  • 18
    • 0034783592 scopus 로고    scopus 로고
    • Bone substitutes in vertebroplasty
    • Heini PF, Berlemann U. Bone substitutes in vertebroplasty. Eur Spine J. 2001;10(suppl):205-213.
    • (2001) Eur Spine J , vol.10 , Issue.SUPPL. , pp. 205-213
    • Heini, P.F.1    Berlemann, U.2
  • 19
    • 0035863342 scopus 로고    scopus 로고
    • An ex vivo biomechanical evaluation of an inflatable bone tamp used in the treatment of compression fracture
    • Belkoff SM, Mathis JM, Fenton DC, et al. An ex vivo biomechanical evaluation of an inflatable bone tamp used in the treatment of compression fracture. Spine. 2001;26:151-156.
    • (2001) Spine , vol.26 , pp. 151-156
    • Belkoff, S.M.1    Mathis, J.M.2    Fenton, D.C.3
  • 20
    • 0033200346 scopus 로고    scopus 로고
    • Biomechanical efficacy of unipedicular versus bipedicular vertebroplasty for the management of osteoporotic compression fractures
    • Tohmeh AG, Mathis JM, Fenton DC, et al. Biomechanical efficacy of unipedicular versus bipedicular vertebroplasty for the management of osteoporotic compression fractures. Spine. 1999;24:1772-1776.
    • (1999) Spine , vol.24 , pp. 1772-1776
    • Tohmeh, A.G.1    Mathis, J.M.2    Fenton, D.C.3
  • 21
    • 0024511174 scopus 로고
    • Prediction of vertebral strength by dual photon absorptiometry and quantitative computed tomography
    • Eriksson SAV, Isberg BO, Lindgren JU. Prediction of vertebral strength by dual photon absorptiometry and quantitative computed tomography. Calcif Tissue Int. 1989;44:243-250.
    • (1989) Calcif Tissue Int , vol.44 , pp. 243-250
    • Eriksson, S.A.V.1    Isberg, B.O.2    Lindgren, J.U.3
  • 22
    • 0035879117 scopus 로고    scopus 로고
    • The biomechanics of vertebroplasty: The effect of cement volume on mechanical behavior
    • Belkoff SM, Mathis JM, Jasper LE, et al. The biomechanics of vertebroplasty: the effect of cement volume on mechanical behavior. Spine. 2001;26:1537-1541.
    • (2001) Spine , vol.26 , pp. 1537-1541
    • Belkoff, S.M.1    Mathis, J.M.2    Jasper, L.E.3
  • 23
    • 0038638438 scopus 로고    scopus 로고
    • The effect of vertebral body percentage fill on mechanical behavior during percutaneous vertebroplasty
    • Molloy S, Mathis JM, Belkoff SM. The effect of vertebral body percentage fill on mechanical behavior during percutaneous vertebroplasty. Spine. 2003; 28:1549-1554.
    • (2003) Spine , vol.28 , pp. 1549-1554
    • Molloy, S.1    Mathis, J.M.2    Belkoff, S.M.3
  • 24
    • 0036505001 scopus 로고    scopus 로고
    • Balloon vertebroplasty with calcium phosphate cement augmentation for direct restoration of traumatic thoracolumbar vertebral fractures
    • Verlaan JJ, van Helden WH, Oner FC, et al. Balloon vertebroplasty with calcium phosphate cement augmentation for direct restoration of traumatic thoracolumbar vertebral fractures. Spine. 2002;27:543-548.
    • (2002) Spine , vol.27 , pp. 543-548
    • Verlaan, J.J.1    Van Helden, W.H.2    Oner, F.C.3
  • 25
    • 0036774297 scopus 로고    scopus 로고
    • Percutaneous transpedicular vertebroplasty with calcium phosphate cement in the treatment of osteoporotic vertebral compression and burst fractures
    • Nakano M, Hirano N, Matsuura K, et al. Percutaneous transpedicular vertebroplasty with calcium phosphate cement in the treatment of osteoporotic vertebral compression and burst fractures. J Neurosurg. 2002;97:287-293.
    • (2002) J Neurosurg , vol.97 , pp. 287-293
    • Nakano, M.1    Hirano, N.2    Matsuura, K.3
  • 26
    • 0037305736 scopus 로고    scopus 로고
    • Acute bronchospasm due to exposure to polymethylmethacrylate vapors during percutaneous vertebroplasty
    • Kirby, BS, Doyle A, Gilula LA. Acute bronchospasm due to exposure to polymethylmethacrylate vapors during percutaneous vertebroplasty [Abstract]. AJR Am J Roentgenol. 2003;180:543-544.
    • (2003) AJR Am J Roentgenol , vol.180 , pp. 543-544
    • Kirby, B.S.1    Doyle, A.2    Gilula, L.A.3
  • 27
    • 0037096636 scopus 로고    scopus 로고
    • Biomechanical evaluation of an injectable calcium phosphate cement for vertebroplasty
    • Lim TH, Brebach GT, Renner SM, et al. Biomechanical evaluation of an injectable calcium phosphate cement for vertebroplasty. Spine. 2002;27: 1297-1302.
    • (2002) Spine , vol.27 , pp. 1297-1302
    • Lim, T.H.1    Brebach, G.T.2    Renner, S.M.3
  • 28
    • 0002258343 scopus 로고
    • Development of α-TCP based bioactive cement
    • Hirano M. Development of α-TCP based bioactive cement. New Ceramics. 1993;5:55-59.
    • (1993) New Ceramics , vol.5 , pp. 55-59
    • Hirano, M.1
  • 29
    • 26644438911 scopus 로고    scopus 로고
    • Improvement in the calcium phosphate bone cement "BIOPEX"
    • Hirano M, Asaoka N, Mitsusuna M, et al. Improvement in the calcium phosphate bone cement "BIOPEX." Med Postgrad. 2002;40:61-67.
    • (2002) Med Postgrad , vol.40 , pp. 61-67
    • Hirano, M.1    Asaoka, N.2    Mitsusuna, M.3
  • 30
    • 0002458757 scopus 로고
    • A biomechanical strengthening of the vertebra with osteoporosis using hydroxyapatite cement injection
    • Shibata T, Yamamoto H, Iai H, et al. A biomechanical strengthening of the vertebra with osteoporosis using hydroxyapatite cement injection. J Jpn Spine Res Soc. 1995;6:61-69.
    • (1995) J Jpn Spine Res Soc , vol.6 , pp. 61-69
    • Shibata, T.1    Yamamoto, H.2    Iai, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.