메뉴 건너뛰기




Volumn , Issue , 2004, Pages 579-580

Improvements in the AC-DC current transfer calibration capabilities at NRC

Author keywords

[No Author keywords available]

Indexed keywords

ACOUSTIC NOISE; ELECTRIC CURRENT MEASUREMENT; ELECTRIC LOAD FLOW;

EID: 33746356404     PISSN: 05891485     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/CPEM.2004.305388     Document Type: Conference Paper
Times cited : (2)

References (8)
  • 1
    • 0005805165 scopus 로고    scopus 로고
    • Extension of the NIST AC-DC Difference Calibration Service for Current to 100 kHz
    • January-February
    • J.R. Kinard, T.E. Lipe, and C.B. Childers, "Extension of the NIST AC-DC Difference Calibration Service for Current to 100 kHz," J Res. NIST, vol. 102, No. 1, pp. 75-83, January-February 1997.
    • (1997) J Res. NIST , vol.102 , Issue.1 , pp. 75-83
    • Kinard, J.R.1    Lipe, T.E.2    Childers, C.B.3
  • 2
    • 0033704614 scopus 로고    scopus 로고
    • An Automated AC-DC Calibration System
    • April
    • P.S. Filipski, R.L. Rinfret, "An Automated AC-DC Calibration System," IEEE Trans. Instrum. Meas., vol. 49, pp. 279-284, April 2000.
    • (2000) IEEE Trans. Instrum. Meas , vol.49 , pp. 279-284
    • Filipski, P.S.1    Rinfret, R.L.2
  • 3
    • 0029290491 scopus 로고
    • Measuring Thermoelectric Effects in Thermal Converters with a Fast Reversed DC
    • April
    • M. Klonz et al, "Measuring Thermoelectric Effects in Thermal Converters with a Fast Reversed DC," IEEE Trans. Instrum. Meas., vol. 44, pp. 379-382, April 1995.
    • (1995) IEEE Trans. Instrum. Meas , vol.44 , pp. 379-382
    • Klonz, M.1
  • 4
    • 0005409990 scopus 로고    scopus 로고
    • Calorimetric Thermal Voltage Converter as a Wideband Calculable Standard of AC-DC Difference
    • April
    • P.S. Filipski, R.F. Clark, and D.C. Paulusse, "Calorimetric Thermal Voltage Converter as a Wideband Calculable Standard of AC-DC Difference," IEEE Trans. Instrum. Meas., vol. 48, pp. 387-390, April 1999.
    • (1999) IEEE Trans. Instrum. Meas , vol.48 , pp. 387-390
    • Filipski, P.S.1    Clark, R.F.2    Paulusse, D.C.3
  • 5
    • 48349130680 scopus 로고    scopus 로고
    • VNIIM, Russia, private communication
    • E.Z. Shapiro, VNIIM, Russia, private communication.
    • Shapiro, E.Z.1
  • 6
    • 0029290090 scopus 로고
    • A Measuring System for Calibration of Power Analyzers
    • April
    • S. Svensson and K-E. Rydler, "A Measuring System for Calibration of Power Analyzers," IEEE Trans. Instrum. Meas., vol. 44, No. 2, pp. 316-317, April 1995.
    • (1995) IEEE Trans. Instrum. Meas , vol.44 , Issue.2 , pp. 316-317
    • Svensson, S.1    Rydler, K.-E.2
  • 7
    • 0031121865 scopus 로고    scopus 로고
    • A Micropotentiometer-based System for Low Voltage Calibration of Alternating Voltage Measurement Standards
    • April
    • I. Budovsky, "A Micropotentiometer-based System for Low Voltage Calibration of Alternating Voltage Measurement Standards," IEEE Trans. Instrum. Meas., vol. 46, No. 2, pp. 356-360, April 1997.
    • (1997) IEEE Trans. Instrum. Meas , vol.46 , Issue.2 , pp. 356-360
    • Budovsky, I.1
  • 8
    • 0028582835 scopus 로고
    • High Accuracy Low-Voltage AC-DC Transfer Standard
    • 94, Boulder, CO, pp, June 27- July 1
    • K-E. Rydler and P. Simonson, "High Accuracy Low-Voltage AC-DC Transfer Standard," Dig.Conf Prec. Electrom. Meas. CPEM'94, Boulder, CO, pp. 382-383, June 27- July 1, 1994.
    • (1994) Dig.Conf Prec. Electrom. Meas. CPEM , pp. 382-383
    • Rydler, K.-E.1    Simonson, P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.