Volumn 48, Issue 2, 1999, Pages 387-390

Calorimetric thermal voltage converter as a wideband calculable standard of AC-DC difference

Author keywords

AC DC transfer; Calibration; Coaxial transmission lines; Electric variables measurement; Measurement standard; Thermal converter

Indexed keywords


EID: 0005409990     PISSN: 00189456     EISSN: None     Source Type: Journal    
DOI: 10.1109/19.769607     Document Type: Article
Times cited : (22)

References (7)
  • 1
    • 0031121866 scopus 로고    scopus 로고
    • CCE comparison of AC-DC voltage transfer standards at the lowest attainable level of uncertainty
    • Apr.
    • M. Klonz "CCE comparison of AC-DC voltage transfer standards at the lowest attainable level of uncertainty," IEEE Trans. Instrum. Meas., vol. 46, pp. 342-346, Apr. 1997.
    • (1997) IEEE Trans. Instrum. Meas. , vol.46 , pp. 342-346
    • Klonz, M.1
  • 2
    • 0024645840 scopus 로고
    • Determination of AC-DC difference in the 0.1-100 MHz frequency range
    • Apr.
    • J.R. Kinard and T.-X. Cai, "Determination of AC-DC difference in the 0.1-100 MHz frequency range," IEEE Trans. Instrum. Meas., vol. 38, pp. 360-367, Apr. 1989.
    • (1989) IEEE Trans. Instrum. Meas. , vol.38 , pp. 360-367
    • Kinard, J.R.1    Cai, T.-X.2
  • 5
    • 0031121523 scopus 로고    scopus 로고
    • Improvements in the NRC AC-DC transfer capabilities
    • Apr.
    • R.F. Clark, p. S. Filipski, and D. C. Paulusse, "Improvements in the NRC AC-DC transfer capabilities," IEEE Trans. Instrum. Meas., vol. 46, pp. 365-368, Apr. 1997.
    • (1997) IEEE Trans. Instrum. Meas. , vol.46 , pp. 365-368
    • Clark, R.F.1    Filipski, P.S.2    Paulusse, D.C.3
  • 6
    • 0030643560 scopus 로고    scopus 로고
    • Evaluation of LF ac-dc difference of coaxially mounted thermal voltage converter
    • Ottawa, Ont., Canada, May 19-21
    • _, "Evaluation of LF ac-dc difference of coaxially mounted thermal voltage converter," in Dig. Instrumentation Measurement Technology Conf. IMTC'97, Ottawa, Ont., Canada, May 19-21, 1997, pp. 720-725.
    • (1997) Dig. Instrumentation Measurement Technology Conf. IMTC'97 , pp. 720-725
  • 7
    • 0002117689 scopus 로고
    • A 10 ppm accurate digital AC measurement algorithm
    • Presented at National Conf. Standards Laboratories, Albuquerque, NM, Aug.
    • R.L. Swerlein, "A 10 ppm accurate digital AC measurement algorithm," Presented at National Conf. Standards Laboratories, in Proc. 1991 Workshop Symp., Albuquerque, NM, Aug. 1991, p. 17.
    • (1991) Proc. 1991 Workshop Symp. , pp. 17
    • Swerlein, R.L.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.