메뉴 건너뛰기




Volumn 4046 LNCS, Issue , 2006, Pages 97-104

Mammography reading with Computer-Aided Detection (CAD): Performance of different readers

Author keywords

[No Author keywords available]

Indexed keywords

BIOLOGICAL ORGANS; COMPUTER AIDED DIAGNOSIS; IMAGE PROCESSING; RADIOLOGY; TUMORS;

EID: 33746341210     PISSN: 03029743     EISSN: 16113349     Source Type: Book Series    
DOI: 10.1007/11783237_14     Document Type: Conference Paper
Times cited : (3)

References (8)
  • 1
    • 0005482571 scopus 로고    scopus 로고
    • Potential contribution of computer-aided detection to the sensitivity of screening mammography
    • Burhenne, LW, Wood S, D'Orsi CJ, Feig SA, Kopans DB, O'Shaughnessy KF, et al. Potential contribution of computer-aided detection to the sensitivity of screening mammography. Radiology 2000; 215(2):554-62
    • (2000) Radiology , vol.215 , Issue.2 , pp. 554-562
    • Burhenne, L.W.1    Wood, S.2    D'Orsi, C.J.3    Feig, S.A.4    Kopans, D.B.5    O'Shaughnessy, K.F.6
  • 2
    • 3142657968 scopus 로고    scopus 로고
    • Comparison of two commercial systems for computer aided detection (CAD) as an aid to interpreting screening mammograms
    • Ciatto S, Ambrogetti D, Bonardi R et al Comparison of two commercial systems for computer aided detection (CAD) as an aid to interpreting screening mammograms. Radiol Med (Torino) 2004; 107 (5-6) : 480-488
    • (2004) Radiol Med (Torino) , vol.107 , Issue.5-6 , pp. 480-488
    • Ciatto, S.1    Ambrogetti, D.2    Bonardi, R.3
  • 3
    • 15744369580 scopus 로고    scopus 로고
    • Computer-aided detection (CAD) in mammography: Does it help the junior or senior radiologist?
    • Balleyguier C, Kinkel K et al Computer-aided detection (CAD) in mammography: does it help the junior or senior radiologist? Eur J Radiol 2005 54(1): 90-6
    • (2005) Eur J Radiol , vol.54 , Issue.1 , pp. 90-96
    • Balleyguier, C.1    Kinkel, K.2
  • 4
    • 84941149116 scopus 로고    scopus 로고
    • Comparison of double reading and single reading with CAD in the UK NHS Breast Screening Program: Computer Aided Detection Evaluation Trial. (CADET)
    • In press
    • Gilbert FJ, Astley SM, McGee MA, Gillan MGC, Boggis CRM, Griffiths PM and Duffy SW. Comparison of double reading and single reading with CAD in the UK NHS Breast Screening Program: Computer Aided Detection Evaluation Trial. (CADET). Radiology (In press)
    • Radiology
    • Gilbert, F.J.1    Astley, S.M.2    McGee, M.A.3    Gillan, M.G.C.4    Boggis, C.R.M.5    Griffiths, P.M.6    Duffy, S.W.7
  • 5
    • 84941147517 scopus 로고    scopus 로고
    • accessed 10.02.06
    • http://www.r2tech.com/mammography/home/index.php accessed 10.02.06
  • 6
    • 7644234308 scopus 로고    scopus 로고
    • Computer-aided detection in screening mammography: The impact of training on reader performance
    • Ed E. Pisano
    • Astley S, Quarterman C, Al Nuami Y et al. Computer-aided detection in screening mammography: the impact of training on reader performance, In: IWDM 2004, Ed E. Pisano, 2005:231-236
    • (2005) IWDM 2004 , pp. 231-236
    • Astley, S.1    Quarterman, C.2    Al Nuami, Y.3
  • 7
    • 0034860859 scopus 로고    scopus 로고
    • Screening mammography with computer-aided detection: Prospective study of 12,860 patients in a community breast center
    • Freer TW, Ulissey MJ. Screening mammography with computer-aided detection: prospective study of 12,860 patients in a community breast center. Radiology 2001; 220:781-786
    • (2001) Radiology , vol.220 , pp. 781-786
    • Freer, T.W.1    Ulissey, M.J.2
  • 8
    • 1342263571 scopus 로고    scopus 로고
    • Changes in breast cancer detection and mammography recall rates after the introduction of a computer-aided detection system
    • Gur D, Sumkin JH, Rockette HE, et al. Changes in breast cancer detection and mammography recall rates after the introduction of a computer-aided detection system. J Natl Cancer Inst 2004; 96:185-190.
    • (2004) J Natl Cancer Inst , vol.96 , pp. 185-190
    • Gur, D.1    Sumkin, J.H.2    Rockette, H.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.