메뉴 건너뛰기




Volumn 32, Issue 2, 2006, Pages 155-168

Comparison of Carbon-impregnated and Standard ePTFE Prostheses in Extra-anatomical Anterior Tibial Artery Bypass: A Prospective Randomized Multicenter Study

Author keywords

Anterior tibial artery; Biomaterials, Carbon; Chronic critical ischemia; Crural bypass, extraanatomic; Peripheral arterial occlusive disease (pAOD); Polytetrafluoroethylene; Prospective randomized multicentric trial

Indexed keywords

ACETYLSALICYLIC ACID; CARBON; CLOPIDOGREL; DANAPAROID; HEPARIN; LOW MOLECULAR WEIGHT HEPARIN; POLITEF; TICLOPIDINE; WARFARIN;

EID: 33746210927     PISSN: 10785884     EISSN: 15322165     Source Type: Journal    
DOI: 10.1016/j.ejvs.2005.12.015     Document Type: Article
Times cited : (45)

References (69)
  • 2
    • 0026550767 scopus 로고
    • The economics of femorocrural reconstruction for critical leg ischemia with and without autologous vein
    • Cheshire N.J., Wolfe J.H., Noone M.A., Davies L., and Drummond M. The economics of femorocrural reconstruction for critical leg ischemia with and without autologous vein. J Vasc Surg 15 1 (1992) 167-174
    • (1992) J Vasc Surg , vol.15 , Issue.1 , pp. 167-174
    • Cheshire, N.J.1    Wolfe, J.H.2    Noone, M.A.3    Davies, L.4    Drummond, M.5
  • 3
    • 0027515683 scopus 로고
    • Tibial bypass grafting for limb salvage with ringed polytetrafluoroethylene prostheses: results of primary and secondary procedures
    • Schweiger H., Klein P., and Lang W. Tibial bypass grafting for limb salvage with ringed polytetrafluoroethylene prostheses: results of primary and secondary procedures. J Vasc Surg 18 5 (1993) 867-874
    • (1993) J Vasc Surg , vol.18 , Issue.5 , pp. 867-874
    • Schweiger, H.1    Klein, P.2    Lang, W.3
  • 4
    • 0030028635 scopus 로고    scopus 로고
    • Polytetrafluoroethylene bypasses to infrapopliteal arteries without cuffs or patches: a better option than amputation in patients without autologous vein
    • Parsons R.E., Suggs W.D., Veith F.J., Sanchez L.A., Lyon R.T., Marin M.L., et al. Polytetrafluoroethylene bypasses to infrapopliteal arteries without cuffs or patches: a better option than amputation in patients without autologous vein. J Vasc Surg 23 2 (1996) 347-354
    • (1996) J Vasc Surg , vol.23 , Issue.2 , pp. 347-354
    • Parsons, R.E.1    Suggs, W.D.2    Veith, F.J.3    Sanchez, L.A.4    Lyon, R.T.5    Marin, M.L.6
  • 5
    • 0022645576 scopus 로고
    • Six-year prospective multicenter randomized comparison of autologous saphenous vein and expanded polytetrafluoroethylene grafts in infrainguinal arterial reconstructions
    • Veith F.J., Gupta S.K., Ascer E., White-Flores S., Samson R.H., Scher L.A., et al. Six-year prospective multicenter randomized comparison of autologous saphenous vein and expanded polytetrafluoroethylene grafts in infrainguinal arterial reconstructions. J Vasc Surg 3 1 (1986) 104-114
    • (1986) J Vasc Surg , vol.3 , Issue.1 , pp. 104-114
    • Veith, F.J.1    Gupta, S.K.2    Ascer, E.3    White-Flores, S.4    Samson, R.H.5    Scher, L.A.6
  • 6
    • 0023951804 scopus 로고
    • Comparative evaluation of prosthetic, reversed, and in situ vein bypass grafts in distal popliteal and tibial-peroneal revascularization. Veterans Administration Cooperative Study Group
    • Veterans Administration Cooperative Study Group
    • Veterans Administration Cooperative Study Group. Comparative evaluation of prosthetic, reversed, and in situ vein bypass grafts in distal popliteal and tibial-peroneal revascularization. Veterans Administration Cooperative Study Group. Arch Surg 123 4 (1988) 434-438
    • (1988) Arch Surg , vol.123 , Issue.4 , pp. 434-438
  • 7
    • 0025824353 scopus 로고
    • Infrapopliteal bypass for severe ischemia: comparison of autogenous vein, composite, and prosthetic grafts
    • Londrey G.L., Ramsey D.E., Hodgson K.J., Barkmeier L.D., and Sumner D.S. Infrapopliteal bypass for severe ischemia: comparison of autogenous vein, composite, and prosthetic grafts. J Vasc Surg 13 5 (1991) 631-636
    • (1991) J Vasc Surg , vol.13 , Issue.5 , pp. 631-636
    • Londrey, G.L.1    Ramsey, D.E.2    Hodgson, K.J.3    Barkmeier, L.D.4    Sumner, D.S.5
  • 8
    • 0007468557 scopus 로고
    • The coating of intravascular plastic prostheses with colloidal graphite
    • Gott V.L., Koepke D.E., Daggett R.L., Zarnstorff W., and Young W.P. The coating of intravascular plastic prostheses with colloidal graphite. Surgery 50 (1961) 382-389
    • (1961) Surgery , vol.50 , pp. 382-389
    • Gott, V.L.1    Koepke, D.E.2    Daggett, R.L.3    Zarnstorff, W.4    Young, W.P.5
  • 9
    • 8944220981 scopus 로고
    • Replacement of the canine pulmonary valve and pulmonary artery with a graphite-coated valve prosthesis
    • Gott V.L., Daggett R.L., Koepke D.E., Rowe G.G., and Young W.P. Replacement of the canine pulmonary valve and pulmonary artery with a graphite-coated valve prosthesis. J Thorac Cardiovasc Surg 44 (1962) 713-723
    • (1962) J Thorac Cardiovasc Surg , vol.44 , pp. 713-723
    • Gott, V.L.1    Daggett, R.L.2    Koepke, D.E.3    Rowe, G.G.4    Young, W.P.5
  • 10
    • 37049246701 scopus 로고
    • Heparin bonding on colloidal graphite surfaces
    • Gott V.L., Whiffen J.D., and Dutton R.C. Heparin bonding on colloidal graphite surfaces. Science 142 (1963) 1297-1298
    • (1963) Science , vol.142 , pp. 1297-1298
    • Gott, V.L.1    Whiffen, J.D.2    Dutton, R.C.3
  • 12
    • 0014088970 scopus 로고
    • Bioelectric properties of the vascular system as related to artificial internal organs
    • Sharp W.V. Bioelectric properties of the vascular system as related to artificial internal organs. Surgery 61 5 (1967) 763-767
    • (1967) Surgery , vol.61 , Issue.5 , pp. 763-767
    • Sharp, W.V.1
  • 14
    • 0017861743 scopus 로고
    • Carbon fiber-reinforced carbon as a potential implant material
    • Adams D., Williams D.F., and Hill J. Carbon fiber-reinforced carbon as a potential implant material. J Biomed Mater Res 12 1 (1978) 35-42
    • (1978) J Biomed Mater Res , vol.12 , Issue.1 , pp. 35-42
    • Adams, D.1    Williams, D.F.2    Hill, J.3
  • 15
    • 0016150674 scopus 로고
    • Pyrolytic biocarbon materials
    • Olcott E.L. Pyrolytic biocarbon materials. J Biomed Mater Res 8 3 (1974) 209-217
    • (1974) J Biomed Mater Res , vol.8 , Issue.3 , pp. 209-217
    • Olcott, E.L.1
  • 16
  • 17
    • 0015168944 scopus 로고
    • The importance of zeta potential, ultrastructure, and electrical conductivity to the in vivo performance of polyurethane-carbon black vascular prostheses
    • Taylor B.C., Sharp W.V., Wright J.I., Ewing K.L., and Wilson C.L. The importance of zeta potential, ultrastructure, and electrical conductivity to the in vivo performance of polyurethane-carbon black vascular prostheses. Trans Am Soc Artif Intern Organs 17 (1971) 22-26
    • (1971) Trans Am Soc Artif Intern Organs , vol.17 , pp. 22-26
    • Taylor, B.C.1    Sharp, W.V.2    Wright, J.I.3    Ewing, K.L.4    Wilson, C.L.5
  • 18
    • 33746196093 scopus 로고
    • Pyrolytic carbon-coated grafts
    • Dardik H. (Ed), Year Book Medical Publishers, Chicago
    • Sharp W.V., and Teague P.C. Pyrolytic carbon-coated grafts. In: Dardik H. (Ed). Graft materials in vascular surgery (1978), Year Book Medical Publishers, Chicago 203-212
    • (1978) Graft materials in vascular surgery , pp. 203-212
    • Sharp, W.V.1    Teague, P.C.2
  • 20
    • 15144341730 scopus 로고
    • Biocompatability of perfluoroninated polymers and composites of these polymers
    • Williams D.F. (Ed), CRC Press Inc., Boca Raton, Florida
    • Homsy C.A. Biocompatability of perfluoroninated polymers and composites of these polymers. In: Williams D.F. (Ed). Biocompatibility of clinical implant materials vol. 2 (1981), CRC Press Inc., Boca Raton, Florida 59-77
    • (1981) Biocompatibility of clinical implant materials , vol.2 , pp. 59-77
    • Homsy, C.A.1
  • 21
    • 0342724456 scopus 로고
    • Update on carbon coated grafts
    • Sawyer P.N. (Ed), McGraw Hill, New York
    • Sharp W.V. Update on carbon coated grafts. In: Sawyer P.N. (Ed). Modern vascular grafts (1987), McGraw Hill, New York 215-224
    • (1987) Modern vascular grafts , pp. 215-224
    • Sharp, W.V.1
  • 23
    • 0018197202 scopus 로고
    • Modified graphite-expanded PTFE (G-PTFE) for use as a superior vena cava (SVC) substitute
    • Goldfarb D., Houk J., Moore Sr. J., and Catron W. Modified graphite-expanded PTFE (G-PTFE) for use as a superior vena cava (SVC) substitute. Trans Am Soc Artif Intern Organs 24 (1978) 201-208
    • (1978) Trans Am Soc Artif Intern Organs , vol.24 , pp. 201-208
    • Goldfarb, D.1    Houk, J.2    Moore Sr., J.3    Catron, W.4
  • 25
    • 0020756654 scopus 로고
    • ULTI carbon goretex: a new vascular graft
    • Debski R., Borovetz H., Haubold A., and Hardesty R. ULTI carbon goretex: a new vascular graft. Curr Surg 40 3 (1983) 198-200
    • (1983) Curr Surg , vol.40 , Issue.3 , pp. 198-200
    • Debski, R.1    Borovetz, H.2    Haubold, A.3    Hardesty, R.4
  • 26
    • 0023719130 scopus 로고
    • Thrombogenicity of vascular prostheses in the short-term carotid artery test. A modified in vitro evaluation model
    • Kogel H., Cyba-Altunbay S., Pindur G., Seifried E., and Ostermeyer U. Thrombogenicity of vascular prostheses in the short-term carotid artery test. A modified in vitro evaluation model. Vasa 17 3 (1988) 177-185
    • (1988) Vasa , vol.17 , Issue.3 , pp. 177-185
    • Kogel, H.1    Cyba-Altunbay, S.2    Pindur, G.3    Seifried, E.4    Ostermeyer, U.5
  • 27
    • 0026730165 scopus 로고
    • Modified polytetrafluoroethylene: indium 111-labeled platelet deposition on carbon-lined and high-porosity polytetrafluoroethylene grafts
    • Tsuchida H., Cameron B.L., Marcus C.S., and Wilson S.E. Modified polytetrafluoroethylene: indium 111-labeled platelet deposition on carbon-lined and high-porosity polytetrafluoroethylene grafts. J Vasc Surg 16 4 (1992) 643-649
    • (1992) J Vasc Surg , vol.16 , Issue.4 , pp. 643-649
    • Tsuchida, H.1    Cameron, B.L.2    Marcus, C.S.3    Wilson, S.E.4
  • 28
    • 33746232893 scopus 로고    scopus 로고
    • McHaney J, Banas C, inventors; IMPRA Inc.Tempe Ariz.USA, assignee. Carbon containing vascular graft and method of making it. US patent 5,827,327. 1998 Oct 27.
  • 30
    • 0027220334 scopus 로고
    • The effect of carbon coating and porosity on early patency of expanded polytetrafluoroethylene grafts: an experimental study
    • Akers D.L., Du Y.H., and Kempczinski R.F. The effect of carbon coating and porosity on early patency of expanded polytetrafluoroethylene grafts: an experimental study. J Vasc Surg 18 1 (1993) 10-15
    • (1993) J Vasc Surg , vol.18 , Issue.1 , pp. 10-15
    • Akers, D.L.1    Du, Y.H.2    Kempczinski, R.F.3
  • 31
    • 0028580556 scopus 로고
    • An animal model for the evaluation of graft thrombosis in the acute phase on carbon-lined PTFE prosthesis
    • Babatasi G., Bara L., Galateau F., Agostini D., Massetti M., Gerard J.L., et al. An animal model for the evaluation of graft thrombosis in the acute phase on carbon-lined PTFE prosthesis. Int J Artif Organs 17 12 (1994) 643-650
    • (1994) Int J Artif Organs , vol.17 , Issue.12 , pp. 643-650
    • Babatasi, G.1    Bara, L.2    Galateau, F.3    Agostini, D.4    Massetti, M.5    Gerard, J.L.6
  • 32
    • 0033802350 scopus 로고    scopus 로고
    • Development of intimal hyperplasia in six different vascular prostheses
    • Ao P.Y., Hawthorne W.J., Vicaretti M., and Fletcher J.P. Development of intimal hyperplasia in six different vascular prostheses. Eur J Vasc Endovasc Surg 20 3 (2000) 241-249
    • (2000) Eur J Vasc Endovasc Surg , vol.20 , Issue.3 , pp. 241-249
    • Ao, P.Y.1    Hawthorne, W.J.2    Vicaretti, M.3    Fletcher, J.P.4
  • 33
    • 33746205848 scopus 로고    scopus 로고
    • Bacourt F, et l' A.U.R.C. Étude Prospective Randomisee Comparative de Protheses PTFE Carbone et PTFE Standard en Position Sous Articulaire. 1994 Jun 16; Annual Meeting of the French speaking Society of Vascular Surgery in Deauville; Jun 16-18 1994.
  • 34
    • 0030701944 scopus 로고    scopus 로고
    • Prospective randomized study of carbon-impregnated polytetrafluoroethylene grafts for below-knee popliteal and distal bypass: results at 2 years. The Association Universitaire de Recherche en Chirurgie
    • Bacourt F. Prospective randomized study of carbon-impregnated polytetrafluoroethylene grafts for below-knee popliteal and distal bypass: results at 2 years. The Association Universitaire de Recherche en Chirurgie. Ann Vasc Surg 11 6 (1997) 596-603
    • (1997) Ann Vasc Surg , vol.11 , Issue.6 , pp. 596-603
    • Bacourt, F.1
  • 35
    • 33746232894 scopus 로고    scopus 로고
    • Baste JC, Boissieras P, Midy D, Sassoust F, Martin F, Pheline P. Étude prospective comparative d'une prothese PTFE Carbone versus prothese standard dans les abords vasculaires pour hemodialyse chronique-resultas à un an. 1993 Jun 24; Hopital Saint André, Bordeaux, France. 8th meeting of the French Society of Vascular Surgery, Paris; June 24 1993.
  • 36
    • 13144300036 scopus 로고
    • Carbon-PTFE versus Standard-PTFE AV-Bridge grafts for chronic hemodialysis
    • Henry M.L., and Ferguson R.M. (Eds), W.L. Gore and Ass. Inc. Precept Press
    • Bourquelot P., Stolba J., Cheret P., Fournier F., and Mouton A. Carbon-PTFE versus Standard-PTFE AV-Bridge grafts for chronic hemodialysis. In: Henry M.L., and Ferguson R.M. (Eds). Vascular Access for Hemodialysis-IV (1995), W.L. Gore and Ass. Inc. Precept Press 303-307
    • (1995) Vascular Access for Hemodialysis-IV , pp. 303-307
    • Bourquelot, P.1    Stolba, J.2    Cheret, P.3    Fournier, F.4    Mouton, A.5
  • 39
    • 0021235627 scopus 로고
    • Linton patch angioplasty. An adjunct to distal bypass with polytetrafluoroethylene grafts
    • Batson R.C., Sottiurai V.S., and Craighead C.C. Linton patch angioplasty. An adjunct to distal bypass with polytetrafluoroethylene grafts. Ann Surg 199 6 (1984) 684-693
    • (1984) Ann Surg , vol.199 , Issue.6 , pp. 684-693
    • Batson, R.C.1    Sottiurai, V.S.2    Craighead, C.C.3
  • 40
    • 0021175454 scopus 로고
    • Interposition vein cuff for anastomosis of prosthesis to small artery
    • Miller J.H., Foreman R.K., Ferguson L., and Faris I. Interposition vein cuff for anastomosis of prosthesis to small artery. Aust N Z J Surg 54 3 (1984) 283-285
    • (1984) Aust N Z J Surg , vol.54 , Issue.3 , pp. 283-285
    • Miller, J.H.1    Foreman, R.K.2    Ferguson, L.3    Faris, I.4
  • 41
    • 0026531896 scopus 로고
    • Improved technique for polytetrafluoroethylene bypass grafting: long-term results using anastomotic vein patches
    • Taylor R.S., Loh A., McFarland R.J., Cox M., and Chester J.F. Improved technique for polytetrafluoroethylene bypass grafting: long-term results using anastomotic vein patches. Br J Surg 79 4 (1992) 348-354
    • (1992) Br J Surg , vol.79 , Issue.4 , pp. 348-354
    • Taylor, R.S.1    Loh, A.2    McFarland, R.J.3    Cox, M.4    Chester, J.F.5
  • 43
    • 0037151796 scopus 로고    scopus 로고
    • Post-randomisation exclusions: the intention to treat principle and excluding patients from analysis
    • Fergusson D., Aaron S.D., Guyatt G., and Hebert P. Post-randomisation exclusions: the intention to treat principle and excluding patients from analysis. BMJ 325 7365 (2002) 652-654
    • (2002) BMJ , vol.325 , Issue.7365 , pp. 652-654
    • Fergusson, D.1    Aaron, S.D.2    Guyatt, G.3    Hebert, P.4
  • 44
    • 0030928783 scopus 로고    scopus 로고
    • Recommended standards for reports dealing with lower extremity ischemia: revised version
    • Rutherford R.B., Baker J.D., Ernst C., Johnston K.W., Porter J.M., Ahn S., et al. Recommended standards for reports dealing with lower extremity ischemia: revised version. J Vasc Surg 26 3 (1997) 517-538
    • (1997) J Vasc Surg , vol.26 , Issue.3 , pp. 517-538
    • Rutherford, R.B.1    Baker, J.D.2    Ernst, C.3    Johnston, K.W.4    Porter, J.M.5    Ahn, S.6
  • 45
    • 0035901579 scopus 로고    scopus 로고
    • The revised CONSORT statement for reporting randomized trials: explanation and elaboration
    • Altman D.G., Schulz K.F., Moher D., Egger M., Davidoff F., Elbourne D., et al. The revised CONSORT statement for reporting randomized trials: explanation and elaboration. Ann Intern Med 134 8 (2001) 663-694
    • (2001) Ann Intern Med , vol.134 , Issue.8 , pp. 663-694
    • Altman, D.G.1    Schulz, K.F.2    Moher, D.3    Egger, M.4    Davidoff, F.5    Elbourne, D.6
  • 46
    • 0035901583 scopus 로고    scopus 로고
    • The CONSORT statement: revised recommendations for improving the quality of reports of parallel-group randomized trials
    • Moher D., Schulz K.F., and Altman D.G. The CONSORT statement: revised recommendations for improving the quality of reports of parallel-group randomized trials. Ann Intern Med 134 8 (2001) 657-662
    • (2001) Ann Intern Med , vol.134 , Issue.8 , pp. 657-662
    • Moher, D.1    Schulz, K.F.2    Altman, D.G.3
  • 47
    • 0034602617 scopus 로고    scopus 로고
    • Prevention Conference V: Beyond secondary prevention: identifying the high-risk patient for primary prevention: noninvasive tests of atherosclerotic burden: Writing Group III
    • Greenland P., Abrams J., Aurigemma G.P., Bond M.G., Clark L.T., Criqui M.H., et al. Prevention Conference V: Beyond secondary prevention: identifying the high-risk patient for primary prevention: noninvasive tests of atherosclerotic burden: Writing Group III. Circulation 101 1 (2000) E16-E22
    • (2000) Circulation , vol.101 , Issue.1
    • Greenland, P.1    Abrams, J.2    Aurigemma, G.P.3    Bond, M.G.4    Clark, L.T.5    Criqui, M.H.6
  • 48
    • 0037129980 scopus 로고    scopus 로고
    • The ankle brachial index is associated with leg function and physical activity: the Walking and Leg Circulation Study
    • McDermott M.M., Greenland P., Liu K., Guralnik J.M., Celic L., Criqui M.H., et al. The ankle brachial index is associated with leg function and physical activity: the Walking and Leg Circulation Study. Ann Intern Med 136 12 (2002) 873-883
    • (2002) Ann Intern Med , vol.136 , Issue.12 , pp. 873-883
    • McDermott, M.M.1    Greenland, P.2    Liu, K.3    Guralnik, J.M.4    Celic, L.5    Criqui, M.H.6
  • 50
    • 0025105260 scopus 로고
    • Present status of reversed vein bypass grafting: five-year results of a modern series
    • Taylor Jr. L.M., Edwards J.M., and Porter J.M. Present status of reversed vein bypass grafting: five-year results of a modern series. J Vasc Surg 11 2 (1990) 193-205
    • (1990) J Vasc Surg , vol.11 , Issue.2 , pp. 193-205
    • Taylor Jr., L.M.1    Edwards, J.M.2    Porter, J.M.3
  • 51
    • 0030729352 scopus 로고    scopus 로고
    • Randomized trial comparing infrainguinal polytetrafluoroethylene bypass grafting with and without vein interposition cuff at the distal anastomosis. The Joint Vascular Research Group
    • Stonebridge P.A., Prescott R.J., and Ruckley C.V. Randomized trial comparing infrainguinal polytetrafluoroethylene bypass grafting with and without vein interposition cuff at the distal anastomosis. The Joint Vascular Research Group. J Vasc Surg 26 4 (1997) 543-550
    • (1997) J Vasc Surg , vol.26 , Issue.4 , pp. 543-550
    • Stonebridge, P.A.1    Prescott, R.J.2    Ruckley, C.V.3
  • 52
    • 0034143103 scopus 로고    scopus 로고
    • Tibial and peroneal artery bypasses using polytetrafluoroethylene (PTFE) with an interposition vein cuff
    • Stonebridge P.A., Naidu S., Colgan M.P., Moore D.J., Shanik D.G., and McCollum P.T. Tibial and peroneal artery bypasses using polytetrafluoroethylene (PTFE) with an interposition vein cuff. J R Coll Surg Edinb 45 1 (2000) 17-20
    • (2000) J R Coll Surg Edinb , vol.45 , Issue.1 , pp. 17-20
    • Stonebridge, P.A.1    Naidu, S.2    Colgan, M.P.3    Moore, D.J.4    Shanik, D.G.5    McCollum, P.T.6
  • 53
    • 33746196090 scopus 로고    scopus 로고
    • [Do we need a new morphological analysis method for the 'run-off'? An analysis of more than 700 patients with distal bypass.] Brauchen wir eine neue morphologische Bewertungsmethode des 'Run-Off'? Eine Analyse von mehr als 700 Patienten mit distalem Bypass
    • p. 139
    • Meichelboeck W. [Do we need a new morphological analysis method for the 'run-off'? An analysis of more than 700 patients with distal bypass.] Brauchen wir eine neue morphologische Bewertungsmethode des 'Run-Off'? Eine Analyse von mehr als 700 Patienten mit distalem Bypass. 18th Annual Meeting of the German Society of Vascular and Endovascular Surgery, Sept. 11-14, Würzburg Germany (2002) p. 139
    • (2002) 18th Annual Meeting of the German Society of Vascular and Endovascular Surgery, Sept. 11-14, Würzburg Germany
    • Meichelboeck, W.1
  • 54
    • 84879282750 scopus 로고
    • Suggested standards for reports dealing with lower extremity ischemia. Prepared by the Ad Hoc Committee on Reporting Standards, Society for Vascular Surgery/North American Chapter, International Society for Cardiovascular Surgery
    • Rutherford R.B., Flanigan D.P., Gupta S.K., Johnston K.W., Karmody A., Baker J.D., et al. Suggested standards for reports dealing with lower extremity ischemia. Prepared by the Ad Hoc Committee on Reporting Standards, Society for Vascular Surgery/North American Chapter, International Society for Cardiovascular Surgery. J Vasc Surg 4 1 (1986) 80-94
    • (1986) J Vasc Surg , vol.4 , Issue.1 , pp. 80-94
    • Rutherford, R.B.1    Flanigan, D.P.2    Gupta, S.K.3    Johnston, K.W.4    Karmody, A.5    Baker, J.D.6
  • 55
    • 0038410135 scopus 로고    scopus 로고
    • Meta-analysis of polytetrafluoroethylene bypass grafts to infrapopliteal arteries
    • Albers M., Battistella V.M., Romiti M., Rodrigues A.A., and Pereira C.A. Meta-analysis of polytetrafluoroethylene bypass grafts to infrapopliteal arteries. J Vasc Surg 37 6 (2003) 1263-1269
    • (2003) J Vasc Surg , vol.37 , Issue.6 , pp. 1263-1269
    • Albers, M.1    Battistella, V.M.2    Romiti, M.3    Rodrigues, A.A.4    Pereira, C.A.5
  • 56
    • 0028960876 scopus 로고
    • Infrapopliteal polytetrafluoroethylene and composite bypass: factors influencing patency
    • Fichelle J.M., Marzelle J., Colacchio G., Gigou F., Cormier F., and Cormier J.M. Infrapopliteal polytetrafluoroethylene and composite bypass: factors influencing patency. Ann Vasc Surg 9 2 (1995) 187-196
    • (1995) Ann Vasc Surg , vol.9 , Issue.2 , pp. 187-196
    • Fichelle, J.M.1    Marzelle, J.2    Colacchio, G.3    Gigou, F.4    Cormier, F.5    Cormier, J.M.6
  • 57
    • 0034143808 scopus 로고    scopus 로고
    • Comparison between supra- and infrainguinal inflow sites for infrapopliteal PTFE bypasses with complementary arteriovenous fistula and vein interposition
    • Ascher E., Scheinman M., Mazzariol F., Kallakuri S., and Hingorani A. Comparison between supra- and infrainguinal inflow sites for infrapopliteal PTFE bypasses with complementary arteriovenous fistula and vein interposition. Eur J Vasc Endovasc Surg 19 2 (2000) 138-142
    • (2000) Eur J Vasc Endovasc Surg , vol.19 , Issue.2 , pp. 138-142
    • Ascher, E.1    Scheinman, M.2    Mazzariol, F.3    Kallakuri, S.4    Hingorani, A.5
  • 58
    • 0033999638 scopus 로고    scopus 로고
    • Adjunctive techniques to improve patency of distal prosthetic bypass grafts: polytetrafluoroethylene with remote arteriovenous fistulae versus vein cuffs
    • Kreienberg P.B., Darling III R.C., Chang B.B., Paty P.S., Lloyd W.E., and Shah D.M. Adjunctive techniques to improve patency of distal prosthetic bypass grafts: polytetrafluoroethylene with remote arteriovenous fistulae versus vein cuffs. J Vasc Surg 31 4 (2000) 696-701
    • (2000) J Vasc Surg , vol.31 , Issue.4 , pp. 696-701
    • Kreienberg, P.B.1    Darling III, R.C.2    Chang, B.B.3    Paty, P.S.4    Lloyd, W.E.5    Shah, D.M.6
  • 59
    • 0033916205 scopus 로고    scopus 로고
    • Femorodistal PTFE bypass grafting for severe limb ischaemia: results of a prospective clinical study using a new distal anastomotic technique
    • Ruckert R.I., Settmacher U., Kruger U., and Scholz H. Femorodistal PTFE bypass grafting for severe limb ischaemia: results of a prospective clinical study using a new distal anastomotic technique. Eur J Vasc Endovasc Surg 20 1 (2000) 51-56
    • (2000) Eur J Vasc Endovasc Surg , vol.20 , Issue.1 , pp. 51-56
    • Ruckert, R.I.1    Settmacher, U.2    Kruger, U.3    Scholz, H.4
  • 61
    • 33746222527 scopus 로고    scopus 로고
    • Lang W. Publication of study results: 'Carbon vs. Standard PTFE in below knee popliteal bypass'. 2004. Ref Type: Personal Communication.
  • 62
    • 0142025515 scopus 로고    scopus 로고
    • Comparison of stainless steel stents coated with turbostratic carbon and uncoated stents for percutaneous coronary interventions
    • Haase J., Storger H., Hofmann M., Schwarz C.E., Reinemer H., and Schwarz F. Comparison of stainless steel stents coated with turbostratic carbon and uncoated stents for percutaneous coronary interventions. J Invasive Cardiol 15 10 (2003) 562-565
    • (2003) J Invasive Cardiol , vol.15 , Issue.10 , pp. 562-565
    • Haase, J.1    Storger, H.2    Hofmann, M.3    Schwarz, C.E.4    Reinemer, H.5    Schwarz, F.6
  • 63
    • 10744229783 scopus 로고    scopus 로고
    • Comparison of diamond-like carbon-coated stents versus uncoated stainless steel stents in coronary artery disease
    • Airoldi F., Colombo A., Tavano D., Stankovic G., Klugmann S., Paolillo V., et al. Comparison of diamond-like carbon-coated stents versus uncoated stainless steel stents in coronary artery disease. Am J Cardiol 93 4 (2004) 474-477
    • (2004) Am J Cardiol , vol.93 , Issue.4 , pp. 474-477
    • Airoldi, F.1    Colombo, A.2    Tavano, D.3    Stankovic, G.4    Klugmann, S.5    Paolillo, V.6
  • 64
    • 26944438306 scopus 로고    scopus 로고
    • Impact of carbon coating on the restenosis rate after stenting of atherosclerotic renal artery stenosis
    • Zeller T., Rastan A., Kliem M., Schwarzwalder U., Frank U., Burgelin K., et al. Impact of carbon coating on the restenosis rate after stenting of atherosclerotic renal artery stenosis. J Endovasc Ther 12 5 (2005) 605-611
    • (2005) J Endovasc Ther , vol.12 , Issue.5 , pp. 605-611
    • Zeller, T.1    Rastan, A.2    Kliem, M.3    Schwarzwalder, U.4    Frank, U.5    Burgelin, K.6
  • 65
    • 0034242539 scopus 로고    scopus 로고
    • Evaluation of the biocompatibility of two new diamond-like stent coatings (Dylyn) in a porcine coronary stent model
    • De S.I., Szilard M., Yanming H., Ping X.B., Verbeken E., Neerinck D., et al. Evaluation of the biocompatibility of two new diamond-like stent coatings (Dylyn) in a porcine coronary stent model. J Invasive Cardiol 12 8 (2000) 389-394
    • (2000) J Invasive Cardiol , vol.12 , Issue.8 , pp. 389-394
    • De, S.I.1    Szilard, M.2    Yanming, H.3    Ping, X.B.4    Verbeken, E.5    Neerinck, D.6
  • 66
    • 0034666723 scopus 로고    scopus 로고
    • In vitro analyses of diamond-like carbon coated stents. Reduction of metal ion release, platelet activation, and thrombogenicity
    • Gutensohn K., Beythien C., Bau J., Fenner T., Grewe P., Koester R., et al. In vitro analyses of diamond-like carbon coated stents. Reduction of metal ion release, platelet activation, and thrombogenicity. Thromb Res 99 6 (2000) 577-585
    • (2000) Thromb Res , vol.99 , Issue.6 , pp. 577-585
    • Gutensohn, K.1    Beythien, C.2    Bau, J.3    Fenner, T.4    Grewe, P.5    Koester, R.6
  • 67
    • 0035177054 scopus 로고    scopus 로고
    • Clinical and angiographic outcomes following elective implantation of the carbostent in patients at high risk of restenosis and target vessel failure
    • Antoniucci D., Valenti R., Migliorini A., Moschi G., Trapani M., Bolognese L., et al. Clinical and angiographic outcomes following elective implantation of the carbostent in patients at high risk of restenosis and target vessel failure. Catheter Cardiovasc Interv 54 4 (2001) 420-426
    • (2001) Catheter Cardiovasc Interv , vol.54 , Issue.4 , pp. 420-426
    • Antoniucci, D.1    Valenti, R.2    Migliorini, A.3    Moschi, G.4    Trapani, M.5    Bolognese, L.6
  • 68
    • 0036132132 scopus 로고    scopus 로고
    • Adhesion, cytoskeletal architecture and activation status of primary human macrophages on a diamond-like carbon coated surface
    • Linder S., Pinkowski W., and Aepfelbacher M. Adhesion, cytoskeletal architecture and activation status of primary human macrophages on a diamond-like carbon coated surface. Biomaterials 23 3 (2002) 767-773
    • (2002) Biomaterials , vol.23 , Issue.3 , pp. 767-773
    • Linder, S.1    Pinkowski, W.2    Aepfelbacher, M.3
  • 69
    • 0041566883 scopus 로고    scopus 로고
    • Carbon-coated stents implanted in porcine iliac and renal arteries: histologic and histomorphometric study
    • Galloni M., Prunotto M., Santarelli A., Laborde F., Dibie A., Isaia C., et al. Carbon-coated stents implanted in porcine iliac and renal arteries: histologic and histomorphometric study. J Vasc Interv Radiol 14 8 (2003) 1053-1061
    • (2003) J Vasc Interv Radiol , vol.14 , Issue.8 , pp. 1053-1061
    • Galloni, M.1    Prunotto, M.2    Santarelli, A.3    Laborde, F.4    Dibie, A.5    Isaia, C.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.