Volumn 130-131, Issue SPEC. ISS., 2006, Pages 267-272

Fabrication of a disposable biochip for measuring percent hemoglobin A1c (%HbA1c)

Author keywords

HbA1c; Blood lysis; Disposable biochip; HbA1c; Interdigitated array (IDA) electrode; Micropump

Indexed keywords

AMINO ACIDS; BLOOD; CELLS; EXTRACTION; GLASS BONDING; GLUCOSE; HEMOGLOBIN; ORGANIC ACIDS; VISCOSITY;

EID: 33745987005     PISSN: 09244247     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.sna.2006.02.028     Document Type: Article
Times cited : (27)

References (12)
  • 2
    • 0035865442 scopus 로고    scopus 로고
    • Needle-type dual microsensor for the simultaneous monitoring of glucose and insulin
    • Wang J., and Zhang X. Needle-type dual microsensor for the simultaneous monitoring of glucose and insulin. Anal. Chem. 73 (2001) 844-847
    • (2001) Anal. Chem. , vol.73 , pp. 844-847
    • Wang, J.1    Zhang, X.2
  • 3
    • 4344666269 scopus 로고    scopus 로고
    • Microneedle array for transdermal biological fluid extraction and in situ analysis
    • Mukerjee W.V., Collins S.D., Isseroff R.R., and Smith R.L. Microneedle array for transdermal biological fluid extraction and in situ analysis. Sens. Actuators A-Phys. 114 (2004) 267-275
    • (2004) Sens. Actuators A-Phys. , vol.114 , pp. 267-275
    • Mukerjee, W.V.1    Collins, S.D.2    Isseroff, R.R.3    Smith, R.L.4
  • 4
    • 0032021550 scopus 로고    scopus 로고
    • Development of needle-type glucose sensor with high selectivity
    • Yang Q., Atanasov P., and Wilkins E. Development of needle-type glucose sensor with high selectivity. Sens. Actuators B-Chem. 46 (1998) 249-256
    • (1998) Sens. Actuators B-Chem. , vol.46 , pp. 249-256
    • Yang, Q.1    Atanasov, P.2    Wilkins, E.3
  • 7
  • 8
    • 0034135607 scopus 로고    scopus 로고
    • A surface-micromachined optical self-homodyne polarimetric sensor for noninvasive glucose monitoring
    • Pu C., Zhu Z., and Lo Y.H. A surface-micromachined optical self-homodyne polarimetric sensor for noninvasive glucose monitoring. IEEE Photonics Technol. Lett. 12 2 (2000) 190-192
    • (2000) IEEE Photonics Technol. Lett. , vol.12 , Issue.2 , pp. 190-192
    • Pu, C.1    Zhu, Z.2    Lo, Y.H.3
  • 9
    • 0029098690 scopus 로고
    • Protein-boronic acid conjugates and their binding to low-molecular-mass cis-diols and glycated hemoglobin
    • Frantzen F., Grimsrud K., Heggli D.-E., and Sundrehagen E. Protein-boronic acid conjugates and their binding to low-molecular-mass cis-diols and glycated hemoglobin. J. Chromatogr. B 670 1 (1995) 37-45
    • (1995) J. Chromatogr. B , vol.670 , Issue.1 , pp. 37-45
    • Frantzen, F.1    Grimsrud, K.2    Heggli, D.-E.3    Sundrehagen, E.4
  • 10
    • 0037121011 scopus 로고    scopus 로고
    • Membrane-immobilized haptoglobin as affinity matrix for a hemoglobin-A1c immunosensor
    • Stöllner D., Stöcklein W., Scheller F., and Warsinke A. Membrane-immobilized haptoglobin as affinity matrix for a hemoglobin-A1c immunosensor. Anal. Chim. Acta 470 2 (2002) 111-119
    • (2002) Anal. Chim. Acta , vol.470 , Issue.2 , pp. 111-119
    • Stöllner, D.1    Stöcklein, W.2    Scheller, F.3    Warsinke, A.4
  • 11
    • 33746026672 scopus 로고    scopus 로고
    • Fabrication of electrochemical sensor with tunable electrode distance
    • Yi Y., and Park J.-K. Fabrication of electrochemical sensor with tunable electrode distance. J. Semicond. Technol. Sci. 5 1 (2005) 30-37
    • (2005) J. Semicond. Technol. Sci. , vol.5 , Issue.1 , pp. 30-37
    • Yi, Y.1    Park, J.-K.2
  • 12
    • 0442311894 scopus 로고    scopus 로고
    • A micropump operating with chemically produced oxygen gas
    • Choi Y.H., Son S.U., and Lee S.S. A micropump operating with chemically produced oxygen gas. Sens. Actuators A-Phys. 111 (2004) 8-13
    • (2004) Sens. Actuators A-Phys. , vol.111 , pp. 8-13
    • Choi, Y.H.1    Son, S.U.2    Lee, S.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.