메뉴 건너뛰기




Volumn 46 B46, Issue 3, 1998, Pages 249-256

Development of needle-type glucose sensor with high selectivity

Author keywords

[No Author keywords available]

Indexed keywords

AMPEROMETRIC SENSORS; CATALYST ACTIVITY; DIFFUSION IN SOLIDS; ELECTROCHEMICAL ELECTRODES; ELECTRODEPOSITION; HYDROGEN PEROXIDE; RHODIUM; TRANSDUCERS;

EID: 0032021550     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/s0925-4005(98)00126-9     Document Type: Article
Times cited : (64)

References (25)
  • 1
    • 0026470689 scopus 로고
    • Biosensors: recent trends a review
    • P Vadgama P.W Crump Biosensors: recent trends a review Analyst 117 1992 1657 1670
    • (1992) Analyst , vol.117 , pp. 1657-1670
    • Vadgama, P1    Crump, P.W2
  • 2
    • 0027411735 scopus 로고
    • In vivo glucose monitoring: sense and sensorbility
    • J.C Pickup In vivo glucose monitoring: sense and sensorbility Diabetes Care 16 1993 535 539
    • (1993) Diabetes Care , vol.16 , pp. 535-539
    • Pickup, J.C1
  • 3
    • 0023550338 scopus 로고
    • Glucose infusion arrests the decompensatory phase of hemorrhagic shock
    • F.J Pearce W Drucker Glucose infusion arrests the decompensatory phase of hemorrhagic shock J. Trauma 27 1987 1213 1220
    • (1987) J. Trauma , vol.27 , pp. 1213-1220
    • Pearce, F.J1    Drucker, W2
  • 4
    • 0020402631 scopus 로고
    • Wearable artificial endocreas with needle-type glucose sensor
    • M Shichiri R Kawamori Y Yamasaki N Hakui H Abe Wearable artificial endocreas with needle-type glucose sensor Lancet 20 1982 1129 1132
    • (1982) Lancet , vol.20 , pp. 1129-1132
    • Shichiri, M1    Kawamori, R2    Yamasaki, Y3    Hakui, N4    Abe, H5
  • 6
    • 0026216348 scopus 로고
    • Design and in vitro studies of a needle-type glucose sensor for subcutaneous monitoring
    • D Bindra Y Zhang G.S Wilson Design and in vitro studies of a needle-type glucose sensor for subcutaneous monitoring Anal. Chem. 63 1991 1692 1696
    • (1991) Anal. Chem. , vol.63 , pp. 1692-1696
    • Bindra, D1    Zhang, Y2    Wilson, G.S3
  • 7
    • 84987515833 scopus 로고
    • Modified electrodes for electrochemical sensors
    • J Wang Modified electrodes for electrochemical sensors Electroanalysis 3 1991 255 259
    • (1991) Electroanalysis , vol.3 , pp. 255-259
    • Wang, J1
  • 8
    • 0026709834 scopus 로고
    • Plasticized poly (vinyl-chloride) as a permselective barrier membrane for high-selectivity amperometric sensors and biosensors
    • I.M Christie P Treloar P Vaolgama Plasticized poly (vinyl-chloride) as a permselective barrier membrane for high-selectivity amperometric sensors and biosensors Anal. Chim. Acta 269 1992 65 73
    • (1992) Anal. Chim. Acta , vol.269 , pp. 65-73
    • Christie, I.M1    Treloar, P2    Vaolgama, P3
  • 9
    • 0028418786 scopus 로고
    • Elimination of the acetaminophen interference in an implantable sensor
    • Y Zhang Y Hu G Wilson D Moatti-Sirat V Poitout G Reach Elimination of the acetaminophen interference in an implantable sensor Anal. Chem. 66 1994 1183 1188
    • (1994) Anal. Chem. , vol.66 , pp. 1183-1188
    • Zhang, Y1    Hu, Y2    Wilson, G3    Moatti-Sirat, D4    Poitout, V5    Reach, G6
  • 10
    • 0027650815 scopus 로고
    • Performance of subcutaneously implanted needle-type glucose sensors employing a novel trilayer coating
    • F Moussy D.J Harrison D O'Brien R Rajotte Performance of subcutaneously implanted needle-type glucose sensors employing a novel trilayer coating Anal. Chem. 65 1993 2072 2077
    • (1993) Anal. Chem. , vol.65 , pp. 2072-2077
    • Moussy, F1    Harrison, D.J2    O'Brien, D3    Rajotte, R4
  • 11
    • 0000707017 scopus 로고
    • Electropolymerized 1,2-diaminobenzene as a means to prevent interferences and fouling and to stabilize immobilized enzyme in electrochemical biosensors
    • S Sasso R Pierce R Walla A.M Yacynych Electropolymerized 1,2-diaminobenzene as a means to prevent interferences and fouling and to stabilize immobilized enzyme in electrochemical biosensors Anal. Chem. 62 1990 1111 1117
    • (1990) Anal. Chem. , vol.62 , pp. 1111-1117
    • Sasso, S1    Pierce, R2    Walla, R3    Yacynych, A.M4
  • 12
    • 0027515401 scopus 로고
    • Permselective lipid-poly(o-phenylenediamine) coatings for amperometric biosensing of glucose
    • J Wang H Wu Permselective lipid-poly( o -phenylenediamine) coatings for amperometric biosensing of glucose Anal. Chim. Acta 283 1993 683 688
    • (1993) Anal. Chim. Acta , vol.283 , pp. 683-688
    • Wang, J1    Wu, H2
  • 13
    • 0028183143 scopus 로고
    • A miniaturized Nafion-based glucose sensor: in vitro and in vivo evaluation in dogs
    • F Moussy D.J Harrison RV Rajotte A miniaturized Nafion-based glucose sensor: in vitro and in vivo evaluation in dogs J. Artif. Organs 17 2 1994 88 94
    • (1994) J. Artif. Organs , vol.17 , Issue.2 , pp. 88-94
    • Moussy, F1    Harrison, D.J2    Rajotte, RV3
  • 14
    • 0001492211 scopus 로고
    • Disposable single-use sensors
    • M Green P Hiditch Disposable single-use sensors Anal. Proc. 28 1991 374 377
    • (1991) Anal. Proc. , vol.28 , pp. 374-377
    • Green, M1    Hiditch, P2
  • 15
    • 0026496736 scopus 로고
    • Laboratory evaluation of the glucocard™ blood glucose test meter
    • B.D Lewis Laboratory evaluation of the glucocard™ blood glucose test meter Clin. Chem. 38 1992 2093 2095
    • (1992) Clin. Chem. , vol.38 , pp. 2093-2095
    • Lewis, B.D1
  • 16
    • 33845376869 scopus 로고
    • Electrochemical characterization of surface-bound redox polymers derived from 1,1'-bis[((3-(triethoxysilyl)propyl)amino), carbonyl]cobaltocenium: charge transport, anion binding and use in photoelectrochemical hydrogen generation
    • R.A Simon T.E Mallouk K.A Daube M.S Wrighton Electrochemical characterization of surface-bound redox polymers derived from 1,1'-bis[((3-(triethoxysilyl)propyl)amino), carbonyl]cobaltocenium: charge transport, anion binding and use in photoelectrochemical hydrogen generation Inorg. Chem. 24 1985 3119 3126
    • (1985) Inorg. Chem. , vol.24 , pp. 3119-3126
    • Simon, R.A1    Mallouk, T.E2    Daube, K.A3    Wrighton, M.S4
  • 17
    • 0344584702 scopus 로고
    • Electrochemical behavior of an electrodeposited rhodium electrode in alkaline solution
    • D Cukman M.J Vukovic Electrochemical behavior of an electrodeposited rhodium electrode in alkaline solution Electroanal. Chem. Interfacial Electro-chem. 279 1990 273 282
    • (1990) Electroanal. Chem. Interfacial Electro-chem. , vol.279 , pp. 273-282
    • Cukman, D1    Vukovic, M.J2
  • 18
    • 0000242056 scopus 로고
    • Highly selective membrane-free mediator-free glucose biosensor
    • J Wang J Liu L Chen F Lu Highly selective membrane-free mediator-free glucose biosensor Anal. Chem. 66 1994 3600 3603
    • (1994) Anal. Chem. , vol.66 , pp. 3600-3603
    • Wang, J1    Liu, J2    Chen, L3    Lu, F4
  • 19
    • 0000688048 scopus 로고
    • Miniturized glucose sensors based on electrochemical codeposition of rhodium and glucose oxidase onto carbon-fiber electrode
    • J Wang L Angnes Miniturized glucose sensors based on electrochemical codeposition of rhodium and glucose oxidase onto carbon-fiber electrode Anal. Chem. 64 1992 456 459
    • (1992) Anal. Chem. , vol.64 , pp. 456-459
    • Wang, J1    Angnes, L2
  • 20
    • 33845278436 scopus 로고
    • Electrodeposition of platinum microparticles into polyaniline films with electrocatalytic applications
    • K.M Kost D.E Bartak Electrodeposition of platinum microparticles into polyaniline films with electrocatalytic applications Anal. Chem. 60 1988 2379 2384
    • (1988) Anal. Chem. , vol.60 , pp. 2379-2384
    • Kost, K.M1    Bartak, D.E2
  • 21
    • 0001925416 scopus 로고    scopus 로고
    • Electrodeposition of high-surface area platinum in a well adherent Nafion film on glassy carbon
    • J.H Ye P.S Fedkiw Electrodeposition of high-surface area platinum in a well adherent Nafion film on glassy carbon Electrochim. Acta 41 1996 221 231
    • (1996) Electrochim. Acta , vol.41 , pp. 221-231
    • Ye, J.H1    Fedkiw, P.S2
  • 22
    • 0001091117 scopus 로고
    • Platinum-dispersed Nafion-modified glassy carbon electrode for the determination of hydrogen peroxide in a flow injection system
    • B.T Tay K.P Ang H Gunasingham Platinum-dispersed Nafion-modified glassy carbon electrode for the determination of hydrogen peroxide in a flow injection system Analyst 113 1988 617 620
    • (1988) Analyst , vol.113 , pp. 617-620
    • Tay, B.T1    Ang, K.P2    Gunasingham, H3
  • 23
    • 0024372040 scopus 로고
    • Platinum-dispersed Nafion film modified glassy carbon as an electrocatalytic surface for an amperometric glucose enzyme electrode
    • H Gunasingham C.B Tan Platinum-dispersed Nafion film modified glassy carbon as an electrocatalytic surface for an amperometric glucose enzyme electrode Analyst 114 1989 695 698
    • (1989) Analyst , vol.114 , pp. 695-698
    • Gunasingham, H1    Tan, C.B2
  • 24
    • 0024095481 scopus 로고
    • Characterization of perfluorosulfonic acid polymer coated enzyme electrodes and a miniaturized integrated potentiostat for glucose analysis in whole blood
    • D.J Harrison Characterization of perfluorosulfonic acid polymer coated enzyme electrodes and a miniaturized integrated potentiostat for glucose analysis in whole blood Anal. Chem. 60 1988 2002 2007
    • (1988) Anal. Chem. , vol.60 , pp. 2002-2007
    • Harrison, D.J1
  • 25
    • 85119542142 scopus 로고    scopus 로고
    • S.D. Bruck, Blood Compatible Synthetic Polymers; Thomas: Springfield, IL, 1974, p. 74.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.