메뉴 건너뛰기




Volumn 78, Issue 2, 2006, Pages 423-431

Factors affecting stiffness properties in impacted morsellized bone used in revision hip surgery: An experimental in vitro study

Author keywords

Morsellized bone grafting; Multiway analysis

Indexed keywords

BIOMATERIALS; DISEASES; GRAFTS; STIFFNESS; SURGERY;

EID: 33745944673     PISSN: 00219304     EISSN: 15524965     Source Type: Journal    
DOI: 10.1002/jbm.a.30854     Document Type: Article
Times cited : (15)

References (20)
  • 1
    • 0033766450 scopus 로고    scopus 로고
    • Acetabular reconstruction with impacted morcellized cancellous bone autograft and cemented primary total hip arthroplasty: A 10- to 17-year follow-up study
    • Welten ML, Schreurs BW, Buma P, Verdonschot N, Slooff TJ. Acetabular reconstruction with impacted morcellized cancellous bone autograft and cemented primary total hip arthroplasty: A 10- to 17-year follow-up study. J Arthroplasty 2000;15:819-824.
    • (2000) J Arthroplasty , vol.15 , pp. 819-824
    • Welten, M.L.1    Schreurs, B.W.2    Buma, P.3    Verdonschot, N.4    Slooff, T.J.5
  • 2
    • 0038712235 scopus 로고    scopus 로고
    • Acetabular revision with impacted morselized cancellous bone graft and a cemented cup in patients with rheumatoid arthritis: Three to fourteen-year follow-up
    • Schreurs BW, Thien TM, de Waal Malefijt MC, Buma P, Veth RP, Slooff TJ. Acetabular revision with impacted morselized cancellous bone graft and a cemented cup in patients with rheumatoid arthritis: Three to fourteen-year follow-up. J Bone Joint Surg Am 2003;85-A:647-652.
    • (2003) J Bone Joint Surg Am , vol.85 A , pp. 647-652
    • Schreurs, B.W.1    Thien, T.M.2    De Waal Malefijt, M.C.3    Buma, P.4    Veth, R.P.5    Slooff, T.J.6
  • 4
    • 0042522391 scopus 로고    scopus 로고
    • Femoral impaction grafting with cement in revision total hip replacement. Evolution of the technique and results
    • Halliday BR, English HW, Timperley AJ, Gie GA, Ling RS. Femoral impaction grafting with cement in revision total hip replacement. Evolution of the technique and results. J Bone Joint Surg Br 2003;85:809-817.
    • (2003) J Bone Joint Surg Br , vol.85 , pp. 809-817
    • Halliday, B.R.1    English, H.W.2    Timperley, A.J.3    Gie, G.A.4    Ling, R.S.5
  • 5
    • 0033816259 scopus 로고    scopus 로고
    • Mechanical properties of compacted morselized cancellous bone graft using one-dimensional consolidation testing
    • Voor MJ, Nawab A, Malkani AL, Ullrich CR. Mechanical properties of compacted morselized cancellous bone graft using one-dimensional consolidation testing. J Biomech 2000;33:1683-1688.
    • (2000) J Biomech , vol.33 , pp. 1683-1688
    • Voor, M.J.1    Nawab, A.2    Malkani, A.L.3    Ullrich, C.R.4
  • 6
    • 0037697854 scopus 로고    scopus 로고
    • Techniques to improve the shear strength of impacted bone graft: The effect of particle size and washing of the graft
    • Dunlop DG, Brewster NT, Madabhushi SP, Usmani AS, Pankaj P, Howie CR. Techniques to improve the shear strength of impacted bone graft: The effect of particle size and washing of the graft. J Bone Joint Surg Am 2003;85-A:639-646.
    • (2003) J Bone Joint Surg Am , vol.85 A , pp. 639-646
    • Dunlop, D.G.1    Brewster, N.T.2    Madabhushi, S.P.3    Usmani, A.S.4    Pankaj, P.5    Howie, C.R.6
  • 7
    • 33645078147 scopus 로고    scopus 로고
    • Influence of water and fat content on compressive stiffness properties in impacted morsellised bone. An experimental study on bone pellets
    • Fosse L, Rønningen H, Benum P, Sandven RB. Influence of water and fat content on compressive stiffness properties in impacted morsellised bone. An experimental study on bone pellets. Acta Orthop 2006;77:15-22.
    • (2006) Acta Orthop , vol.77 , pp. 15-22
    • Fosse, L.1    Rønningen, H.2    Benum, P.3    Sandven, R.B.4
  • 9
    • 4544339214 scopus 로고    scopus 로고
    • Impacted bone stiffness measured during construction of morsellised bone samples
    • Fosse L, Rønningen H, Lund-Larsen J, Benum P, Grande L. Impacted bone stiffness measured during construction of morsellised bone samples. J Biomech 2004;37:1757-1766.
    • (2004) J Biomech , vol.37 , pp. 1757-1766
    • Fosse, L.1    Rønningen, H.2    Lund-Larsen, J.3    Benum, P.4    Grande, L.5
  • 10
    • 33745079514 scopus 로고    scopus 로고
    • Craig RF, editor. London: Spon Press
    • Craig RF, editor. Craig's soil mechanics. London: Spon Press; 2004.
    • (2004) Craig's Soil Mechanics
  • 11
    • 0002506538 scopus 로고    scopus 로고
    • Biomechanics of artificial joints: The hip
    • Mow VC, Hayes WC, editors. Philadelphia: Lippincott-Raven
    • Huiskes R, Verdonschot N. Biomechanics of artificial joints: The hip. In: Mow VC, Hayes WC, editors. Basic Orthopaedic Biomechanics. Philadelphia: Lippincott-Raven; 1997. pp 395-460.
    • (1997) Basic Orthopaedic Biomechanics , pp. 395-460
    • Huiskes, R.1    Verdonschot, N.2
  • 13
    • 0033949591 scopus 로고    scopus 로고
    • Bigger size and defatting of bone chips will increase cup stability
    • Ullmark G. Bigger size and defatting of bone chips will increase cup stability. Arch Orthop Trauma Surg 2000;120:445-447.
    • (2000) Arch Orthop Trauma Surg , vol.120 , pp. 445-447
    • Ullmark, G.1
  • 15
    • 0036704087 scopus 로고    scopus 로고
    • Early complications after one hundred and forty-four consecutive hip revisions with impacted morselized allograft bone and cement
    • Ornstein E, Atroshi I, Franzen H, Johnsson R, Sandquist P, Sundberg M. Early complications after one hundred and forty-four consecutive hip revisions with impacted morselized allograft bone and cement. J Bone Joint Surg Am 2002;84-A:1323-1328.
    • (2002) J Bone Joint Surg Am , vol.84 A , pp. 1323-1328
    • Ornstein, E.1    Atroshi, I.2    Franzen, H.3    Johnsson, R.4    Sandquist, P.5    Sundberg, M.6
  • 16
    • 0042759714 scopus 로고    scopus 로고
    • Impaction of cancellous bone grafts impairs osteoconduction in titanium chambers
    • Tagil M, Aspenberg P. Impaction of cancellous bone grafts impairs osteoconduction in titanium chambers. Clin Orthop Relat Res 1998;352:231-238.
    • (1998) Clin Orthop Relat Res , vol.352 , pp. 231-238
    • Tagil, M.1    Aspenberg, P.2
  • 17
    • 0033857165 scopus 로고    scopus 로고
    • Load-bearing increases new bone formation in impacted and morselized allografts
    • Wang JS, Tagil M, Aspenberg P. Load-bearing increases new bone formation in impacted and morselized allografts. Clin Orthop Relat Res 2000;378:274-281.
    • (2000) Clin Orthop Relat Res , vol.378 , pp. 274-281
    • Wang, J.S.1    Tagil, M.2    Aspenberg, P.3
  • 18
    • 0028843376 scopus 로고
    • Lipid extracted bank bone. Bone conductive and mechanical properties
    • Thorén K, Aspenberg P, Thorngren KG. Lipid extracted bank bone. Bone conductive and mechanical properties. Clin Orthop Relat Res 1995;311:232-246.
    • (1995) Clin Orthop Relat Res , vol.311 , pp. 232-246
    • Thorén, K.1    Aspenberg, P.2    Thorngren, K.G.3
  • 20
    • 2942714897 scopus 로고    scopus 로고
    • Impacted morselized cancellous bone: Mechanical effects of defatting and augmentation with fine hydroxyapatite particles
    • Voor MJ, White JE, Grieshaber JE, Malkani AL, Ullrich CR. Impacted morselized cancellous bone: Mechanical effects of defatting and augmentation with fine hydroxyapatite particles. J Biomech 2004;37:1233-1239.
    • (2004) J Biomech , vol.37 , pp. 1233-1239
    • Voor, M.J.1    White, J.E.2    Grieshaber, J.E.3    Malkani, A.L.4    Ullrich, C.R.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.