메뉴 건너뛰기




Volumn 24, Issue 3, 2006, Pages 302-307

Utility of a novel quantitative handheld microstream capnometer during transport of critically ill children

Author keywords

[No Author keywords available]

Indexed keywords

CARBON DIOXIDE;

EID: 33745890224     PISSN: 07356757     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ajem.2005.10.024     Document Type: Article
Times cited : (32)

References (20)
  • 1
    • 0020615043 scopus 로고
    • Toward safer transport of sick and injured children
    • Owen H., and Duncan A.W. Toward safer transport of sick and injured children. Anaesth Intensive Care 11 (1983) 113-117
    • (1983) Anaesth Intensive Care , vol.11 , pp. 113-117
    • Owen, H.1    Duncan, A.W.2
  • 2
    • 0024390209 scopus 로고
    • Adverse events during interhospital transport: physiologic deterioration associated with pretransport severity of illness
    • Kanter R.K., and Tompkins J.M. Adverse events during interhospital transport: physiologic deterioration associated with pretransport severity of illness. Pediatrics 841 (1989) 43-48
    • (1989) Pediatrics , vol.841 , pp. 43-48
    • Kanter, R.K.1    Tompkins, J.M.2
  • 3
    • 0025318032 scopus 로고
    • Pediatric critical care transport survey: team composition and training, mobilization and mode of transportation
    • McClosky K.A., and Johnston C. Pediatric critical care transport survey: team composition and training, mobilization and mode of transportation. Pediatr Emerg Care 61 (1990) 1-3
    • (1990) Pediatr Emerg Care , vol.61 , pp. 1-3
    • McClosky, K.A.1    Johnston, C.2
  • 4
    • 0022512624 scopus 로고
    • Esophageal intubation: a review of detection techniques
    • Birmingham P.K., Cheney F.W., and Ward R.J. Esophageal intubation: a review of detection techniques. Anesth Analg 65 (1986) 886-891
    • (1986) Anesth Analg , vol.65 , pp. 886-891
    • Birmingham, P.K.1    Cheney, F.W.2    Ward, R.J.3
  • 5
    • 0024784353 scopus 로고
    • Capnometry in emergency medicine
    • Sanders A.B. Capnometry in emergency medicine. Ann Emerg Med 18 (1989) 1287-1290
    • (1989) Ann Emerg Med , vol.18 , pp. 1287-1290
    • Sanders, A.B.1
  • 6
    • 0033050304 scopus 로고    scopus 로고
    • Capnography in the pediatric emergency department
    • Bhende M.S. Capnography in the pediatric emergency department. Pediatr Emerg Care 15 1 (1999) 64-69
    • (1999) Pediatr Emerg Care , vol.15 , Issue.1 , pp. 64-69
    • Bhende, M.S.1
  • 7
    • 0024535006 scopus 로고
    • Early detection of inadvertent oesophageal intubation: pulse oximetry vs. capnography
    • Guggenberger H., Lenz G., and Federle R. Early detection of inadvertent oesophageal intubation: pulse oximetry vs. capnography. Acta Anaesthesiol Scand 33 (1989) 112-115
    • (1989) Acta Anaesthesiol Scand , vol.33 , pp. 112-115
    • Guggenberger, H.1    Lenz, G.2    Federle, R.3
  • 8
    • 0024449624 scopus 로고
    • Comparison of end-tidal carbon-dioxide, oxygen saturation and clinical signs for the detection of oesophageal intubation
    • Vaghadia H., Jenkins L.C., and Ford R.W. Comparison of end-tidal carbon-dioxide, oxygen saturation and clinical signs for the detection of oesophageal intubation. Can J Anaesth 36 (1989) 560-564
    • (1989) Can J Anaesth , vol.36 , pp. 560-564
    • Vaghadia, H.1    Jenkins, L.C.2    Ford, R.W.3
  • 9
    • 0342617104 scopus 로고    scopus 로고
    • Utility of monitoring capnography, pulse oximetry and vital signs in detecting airway mishaps: a hyperoxemic animal model
    • Poirier M.P., Gonzalez del Ray J.A., McAneney C.M., et al. Utility of monitoring capnography, pulse oximetry and vital signs in detecting airway mishaps: a hyperoxemic animal model. Am J Emerg Med 16 (1998) 350-352
    • (1998) Am J Emerg Med , vol.16 , pp. 350-352
    • Poirier, M.P.1    Gonzalez del Ray, J.A.2    McAneney, C.M.3
  • 10
    • 17144466194 scopus 로고    scopus 로고
    • Pediatric Advanced Life Support
    • American Heart Association. Pediatric Advanced Life Support. Circulation 102 Suppl I (2000) I-291-I-342
    • (2000) Circulation , vol.102 , Issue.SUPPL. I , pp. 291-342
    • American Heart Association1
  • 11
    • 0026889573 scopus 로고
    • Is portable capnometry useful during transport of critically ill?
    • Runcie C.J., and Reeve W. Is portable capnometry useful during transport of critically ill?. J Clin Monit 8 (1992) 250
    • (1992) J Clin Monit , vol.8 , pp. 250
    • Runcie, C.J.1    Reeve, W.2
  • 12
    • 0026752642 scopus 로고
    • 2 detector during stabilization and transport of critically ill children
    • 2 detector during stabilization and transport of critically ill children. Pediatrics 896 (1992) 1042-1044
    • (1992) Pediatrics , vol.896 , pp. 1042-1044
    • Bhende, M.S.1    Thompson, A.E.2    Orr, R.A.3
  • 13
    • 0029062609 scopus 로고
    • Evaluation of a portable end-tidal carbon dioxide monitor during pediatric interhospital transport
    • Bhende M.S., Karr V.A., Wiltsie D.C., et al. Evaluation of a portable end-tidal carbon dioxide monitor during pediatric interhospital transport. Pediatrics 95 (1995) 875-878
    • (1995) Pediatrics , vol.95 , pp. 875-878
    • Bhende, M.S.1    Karr, V.A.2    Wiltsie, D.C.3
  • 14
    • 0033238016 scopus 로고    scopus 로고
    • Microstream capnography technology: a new approach to an old problem
    • Colman Y., and Krauss B. Microstream capnography technology: a new approach to an old problem. J Clin Monit 15 (1999) 403-409
    • (1999) J Clin Monit , vol.15 , pp. 403-409
    • Colman, Y.1    Krauss, B.2
  • 15
    • 0035038553 scopus 로고    scopus 로고
    • NPB-75: a portable microstream quantitative capnometer
    • Singh S., Venkataraman S.T., Saville A., et al. NPB-75: a portable microstream quantitative capnometer. Am J Emerg Med 19 (2001) 208-210
    • (2001) Am J Emerg Med , vol.19 , pp. 208-210
    • Singh, S.1    Venkataraman, S.T.2    Saville, A.3
  • 17
    • 0025774407 scopus 로고
    • Inability to assess breath sounds during air medical transport by rotorcraft
    • Hunt R.C., Bryan D.M., Brinkley S., et al. Inability to assess breath sounds during air medical transport by rotorcraft. JAMA 26515 (1991) 1982-1984
    • (1991) JAMA , vol.26515 , pp. 1982-1984
    • Hunt, R.C.1    Bryan, D.M.2    Brinkley, S.3
  • 19
    • 0036903455 scopus 로고    scopus 로고
    • Evaluation of a Capnoflow resuscitator during transport of critically ill children
    • Bhende M.S., and Allen W.D. Evaluation of a Capnoflow resuscitator during transport of critically ill children. Pediatr Emerg Care 18 6 (2002) 414-416
    • (2002) Pediatr Emerg Care , vol.18 , Issue.6 , pp. 414-416
    • Bhende, M.S.1    Allen, W.D.2
  • 20
    • 0029780675 scopus 로고    scopus 로고
    • Alterations of end-tidal carbon dioxide during the intrahospital transport of children
    • Tobias J.D., Lynch A., and Garrett J. Alterations of end-tidal carbon dioxide during the intrahospital transport of children. Pediatr Emerg Care 12 4 (1996) 249-251
    • (1996) Pediatr Emerg Care , vol.12 , Issue.4 , pp. 249-251
    • Tobias, J.D.1    Lynch, A.2    Garrett, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.