메뉴 건너뛰기




Volumn 68, Issue 1, 2006, Pages 21-26

The role of covered stents: More than an occasional cameo?

Author keywords

[No Author keywords available]

Indexed keywords

CREATINE KINASE MB; POLITEF; TROPONIN;

EID: 33745798854     PISSN: 15221946     EISSN: 1522726X     Source Type: Journal    
DOI: 10.1002/ccd.20779     Document Type: Review
Times cited : (10)

References (54)
  • 1
    • 0033629805 scopus 로고    scopus 로고
    • Implantation of stems covered by autologous arterial grafts in human coronary arteries: A new technique
    • Stephanadis C, Toutouzas K, Tsiamis E, et al. Implantation of stems covered by autologous arterial grafts in human coronary arteries: A new technique. J Invasive Cardiol 2000;12:7-12.
    • (2000) J Invasive Cardiol , vol.12 , pp. 7-12
    • Stephanadis, C.1    Toutouzas, K.2    Tsiamis, E.3
  • 2
    • 8944259442 scopus 로고    scopus 로고
    • Successful closure of a coronary vessel rupture with a vein graft stem: Case report
    • Colombo A, Itoh A, Di Mario C, et al. Successful closure of a coronary vessel rupture with a vein graft stem: Case report. Cathet Cardiovasc Diagn 1996;38:172-174.
    • (1996) Cathet Cardiovasc Diagn , vol.38 , pp. 172-174
    • Colombo, A.1    Itoh, A.2    Di Mario, C.3
  • 3
    • 0032747773 scopus 로고    scopus 로고
    • Successful treatment of a saphenous vein graft perforation with an autologous vein-covered stent
    • Caputo RP, Amin N, Marvasti M, et al. Successful treatment of a saphenous vein graft perforation with an autologous vein-covered stent. Catheter Cardiovasc Interv 1999;8:382-386.
    • (1999) Catheter Cardiovasc Interv , vol.8 , pp. 382-386
    • Caputo, R.P.1    Amin, N.2    Marvasti, M.3
  • 4
    • 33745793315 scopus 로고    scopus 로고
    • Percutaneous revascularisation of an extensively diseased saphenous vein graft with a saphenous vein-covered Palmaz stent
    • Gurbel PA, Criado FJ, Curnette EA, et al. Percutaneous revascularisation of an extensively diseased saphenous vein graft with a saphenous vein-covered Palmaz stent. Catheter Cardiovasc Interv 1999;47:496-503.
    • (1999) Catheter Cardiovasc Interv , vol.47 , pp. 496-503
    • Gurbel, P.A.1    Criado, F.J.2    Curnette, E.A.3
  • 5
    • 0029027339 scopus 로고
    • Percutaneous implantation of autologous vein graft stent for treatment of coronary artery disease
    • Stephanadis C, Toutouzas K, Vlachopoulos C, et al. Percutaneous implantation of autologous vein graft stent for treatment of coronary artery disease. Lancet 1995;345:1509.
    • (1995) Lancet , vol.345 , pp. 1509
    • Stephanadis, C.1    Toutouzas, K.2    Vlachopoulos, C.3
  • 6
    • 0034060522 scopus 로고    scopus 로고
    • Stents covered by autologous grafts: Feasibility and immediate and long term results
    • Stephanadis C, Toutouzas K, Tsiamis E, et al. Stents covered by autologous grafts: Feasibility and immediate and long term results. Am Heart J 2000;139:439-445.
    • (2000) Am Heart J , vol.139 , pp. 439-445
    • Stephanadis, C.1    Toutouzas, K.2    Tsiamis, E.3
  • 7
    • 0036839631 scopus 로고    scopus 로고
    • Coronary artery perforation during percutaneous intervention: Incidence and outcome
    • Gunning MG, Williams IL, Jewitt DE, et al. Coronary artery perforation during percutaneous intervention: Incidence and outcome. Heart 2002;88:495-498.
    • (2002) Heart , vol.88 , pp. 495-498
    • Gunning, M.G.1    Williams, I.L.2    Jewitt, D.E.3
  • 8
    • 0034687590 scopus 로고    scopus 로고
    • Emergency polytetrafluoroethylene covered stent implantation to treat coronary ruptures
    • Briguori C, Nishida T, Anzuini A, et al. Emergency polytetrafluoroethylene covered stent implantation to treat coronary ruptures. Circulation 2000;102:3028-3031.
    • (2000) Circulation , vol.102 , pp. 3028-3031
    • Briguori, C.1    Nishida, T.2    Anzuini, A.3
  • 9
    • 0032734187 scopus 로고    scopus 로고
    • Repair of left anterior descending coronary artery perforation by magic wall stent implantation
    • Hammoud T, Tanguay J-F, Rios F, et al. Repair of left anterior descending coronary artery perforation by magic wall stent implantation. Catheter Cardiovasc Interv 1999;48:304-307.
    • (1999) Catheter Cardiovasc Interv , vol.48 , pp. 304-307
    • Hammoud, T.1    Tanguay, J.-F.2    Rios, F.3
  • 10
    • 0037598681 scopus 로고    scopus 로고
    • Treatment of recurrent coronary rupture by implantation of three coronary stent grafts
    • Veselka J, Tesar D, Honek T, et al. Treatment of recurrent coronary rupture by implantation of three coronary stent grafts. Int J Cardiovasc Interv 2003;5:88-91.
    • (2003) Int J Cardiovasc Interv , vol.5 , pp. 88-91
    • Veselka, J.1    Tesar, D.2    Honek, T.3
  • 11
    • 0034184135 scopus 로고    scopus 로고
    • The Jomed covered stent graft for coronary artery aneurysms and acute perforation: A successful device which needs careful deployment and may not reduce restenosis
    • Campbell PG, Hall JA, Harcombe AA, et al. The Jomed covered stent graft for coronary artery aneurysms and acute perforation: A successful device which needs careful deployment and may not reduce restenosis. J Invasive Cardiol 2000;12:272-276.
    • (2000) J Invasive Cardiol , vol.12 , pp. 272-276
    • Campbell, P.G.1    Hall, J.A.2    Harcombe, A.A.3
  • 12
    • 0033865713 scopus 로고    scopus 로고
    • Left internal mammary artery graft perforation repair using polytetrafluoroethylene-covered stents
    • Albiero R, Nishida T, Corvaja N, et al. Left internal mammary artery graft perforation repair using polytetrafluoroethylene-covered stents. Catheter Cardiovasc Interv 2000;51:78-82.
    • (2000) Catheter Cardiovasc Interv , vol.51 , pp. 78-82
    • Albiero, R.1    Nishida, T.2    Corvaja, N.3
  • 13
    • 0034702180 scopus 로고    scopus 로고
    • Coronary artery rupture treated with a polytetrafluoroethylene coated stent
    • Nageh T, Thomas MR. Coronary artery rupture treated with a polytetrafluoroethylene coated stent. N Engl J Med 2000;342:1922-1924.
    • (2000) N Engl J Med , vol.342 , pp. 1922-1924
    • Nageh, T.1    Thomas, M.R.2
  • 14
    • 0001307114 scopus 로고    scopus 로고
    • Successful treatment of coronary artery perforation during angioplasty using a new membrane-coated stent
    • Casella G, Werner F, Klauss VV, et al. Successful treatment of coronary artery perforation during angioplasty using a new membrane-coated stent. J Invasive Cardiol 1999;11:622-626.
    • (1999) J Invasive Cardiol , vol.11 , pp. 622-626
    • Casella, G.1    Werner, F.2    Klauss, V.V.3
  • 15
    • 0031787763 scopus 로고    scopus 로고
    • Repair of coronary artery perforation after rotastenting by implantation of the Jostent covered stent
    • Ramsdale DR, Mushahwar SS, Morris JL. Repair of coronary artery perforation after rotastenting by implantation of the Jostent covered stent. Cathet Cardiovasc Diagn 1998;45:310-313.
    • (1998) Cathet Cardiovasc Diagn , vol.45 , pp. 310-313
    • Ramsdale, D.R.1    Mushahwar, S.S.2    Morris, J.L.3
  • 16
    • 0033180262 scopus 로고    scopus 로고
    • Coronary stent grafts covered by a polytetrafluoroethylene membrane
    • Elsner M, Auch-Schwelk W, Britten M, et al. Coronary stent grafts covered by a polytetrafluoroethylene membrane. Am J Cardiol 1999;84:335-338.
    • (1999) Am J Cardiol , vol.84 , pp. 335-338
    • Elsner, M.1    Auch-Schwelk, W.2    Britten, M.3
  • 18
    • 0032899768 scopus 로고    scopus 로고
    • Obliteration of a coronary artery aneurysm with a PTFE-covered stent: Endoluminal graft for coronary disease revisited
    • Heuser RR, Woodfield S, Lopez A. Obliteration of a coronary artery aneurysm with a PTFE-covered stent: Endoluminal graft for coronary disease revisited. Catheter Cardiovasc Interv 1999;46:113-116.
    • (1999) Catheter Cardiovasc Interv , vol.46 , pp. 113-116
    • Heuser, R.R.1    Woodfield, S.2    Lopez, A.3
  • 19
    • 0032759921 scopus 로고    scopus 로고
    • Treatment of a coronary artery aneurysm with a novel stent
    • Kolettis TM, Kyriakides Z, Kremastinos DT. Treatment of a coronary artery aneurysm with a novel stent. Clin Cardiol 1999;22:759-761.
    • (1999) Clin Cardiol , vol.22 , pp. 759-761
    • Kolettis, T.M.1    Kyriakides, Z.2    Kremastinos, D.T.3
  • 20
    • 0033770475 scopus 로고    scopus 로고
    • Left main coronary artery aneurysm sealing by stent graft and long term follow up
    • Leung AW, Wong P, Wu CW, et al. Left main coronary artery aneurysm sealing by stent graft and long term follow up. Catheter Cardiovasc Interv 2000;51:205-209.
    • (2000) Catheter Cardiovasc Interv , vol.51 , pp. 205-209
    • Leung, A.W.1    Wong, P.2    Wu, C.W.3
  • 21
    • 0033053738 scopus 로고    scopus 로고
    • Treatment of a coronary aneurysm with a new polytetrafluoroethylene- coated stem: A case report
    • Di Mario C, Inglese L, Colombo A. Treatment of a coronary aneurysm with a new polytetrafluoroethylene-coated stem: A case report. Catheter Cardiovasc Interv 1999;46:463-465.
    • (1999) Catheter Cardiovasc Interv , vol.46 , pp. 463-465
    • Di Mario, C.1    Inglese, L.2    Colombo, A.3
  • 22
    • 0034020311 scopus 로고    scopus 로고
    • Unsuccessful long term outcome after treatment of a vein graft false aneurysm with a polytetrafluoroethylene-coated Jostent
    • Bosmans JM, Claeys MJ, Dilling D, et al. Unsuccessful long term outcome after treatment of a vein graft false aneurysm with a polytetrafluoroethylene- coated Jostent. Catheter Cardiovasc Interv 2000;50:105-108.
    • (2000) Catheter Cardiovasc Interv , vol.50 , pp. 105-108
    • Bosmans, J.M.1    Claeys, M.J.2    Dilling, D.3
  • 23
    • 1942468126 scopus 로고    scopus 로고
    • Polytetrafluoroethylene (PTFE) covered stents for the treatment of coronary artery aneurysms
    • Fineschi M, Gori T, Sinicropi G, et al. Polytetrafluoroethylene (PTFE) covered stents for the treatment of coronary artery aneurysms. Heart 2004;90:490.
    • (2004) Heart , vol.90 , pp. 490
    • Fineschi, M.1    Gori, T.2    Sinicropi, G.3
  • 24
    • 4143081453 scopus 로고    scopus 로고
    • Percutaneous treatment of a large coronary aneurysm using the self-expandable Symbiot PTFE covered stent
    • Burzotta F, Trani C, Romagnoli E, et al. Percutaneous treatment of a large coronary aneurysm using the self-expandable Symbiot PTFE covered stent. Chest 2004;126:644,645.
    • (2004) Chest , vol.126 , pp. 644-645
    • Burzotta, F.1    Trani, C.2    Romagnoli, E.3
  • 25
    • 0035188474 scopus 로고    scopus 로고
    • Treatment of a saphenous vein graft to right ventricle fistula with a PTFE-covered stent: A case report
    • Smith RW, Schussler JM, Anwar A, et al. Treatment of a saphenous vein graft to right ventricle fistula with a PTFE-covered stent: A case report. Catheter Cardiovasc Interv 2001;54:531-532.
    • (2001) Catheter Cardiovasc Interv , vol.54 , pp. 531-532
    • Smith, R.W.1    Schussler, J.M.2    Anwar, A.3
  • 26
    • 0742325101 scopus 로고    scopus 로고
    • Combined membrane covered and uncovered stents for coronary arteriovenous fistula associated with atherosclerotic plaque in a patient with acute myocardial infarction
    • Ahn Y, Park OY, Jeong MH, et al. Combined membrane covered and uncovered stents for coronary arteriovenous fistula associated with atherosclerotic plaque in a patient with acute myocardial infarction. Heart 2004;90:150.
    • (2004) Heart , vol.90 , pp. 150
    • Ahn, Y.1    Park, O.Y.2    Jeong, M.H.3
  • 27
    • 0025759143 scopus 로고
    • Coronary artery bypass graft fate: Long term angiographic study
    • Fitzgibbon GM, Leach AJ, Kafka HP, et al. Coronary artery bypass graft fate: Long term angiographic study. J Am Coll Cardiol 1991;17:1075-1080.
    • (1991) J Am Coll Cardiol , vol.17 , pp. 1075-1080
    • Fitzgibbon, G.M.1    Leach, A.J.2    Kafka, H.P.3
  • 28
    • 0030317099 scopus 로고    scopus 로고
    • Use of coronary artery bypass surgical procedure and coronary angioplasty in treatment of coronary artery disease: Changes during a 10 year period at the Mayo Clinic Rochester
    • Harris WO, Mock MB, Orszulak TA, et al. Use of coronary artery bypass surgical procedure and coronary angioplasty in treatment of coronary artery disease: Changes during a 10 year period at the Mayo Clinic Rochester. Mayo Clin Proc 1996;71:927-935.
    • (1996) Mayo Clin Proc , vol.71 , pp. 927-935
    • Harris, W.O.1    Mock, M.B.2    Orszulak, T.A.3
  • 29
    • 0028158271 scopus 로고
    • Frequency of repeat coronary bypass or coronary angioplasty after coronary bypass surgery using saphenous venous grafts
    • Weintraub WS, Jones EL, Craver JM, et al. Frequency of repeat coronary bypass or coronary angioplasty after coronary bypass surgery using saphenous venous grafts. Am J Cardiol 1994;73:103-112.
    • (1994) Am J Cardiol , vol.73 , pp. 103-112
    • Weintraub, W.S.1    Jones, E.L.2    Craver, J.M.3
  • 30
    • 0031056021 scopus 로고    scopus 로고
    • Outcome of reoperative coronary bypass surgery versus coronary angioplasty after previous bypass surgery
    • Weintraub WS, Jones EL, Morris DC, et al. Outcome of reoperative coronary bypass surgery versus coronary angioplasty after previous bypass surgery. Circulation 1997;95:868-877.
    • (1997) Circulation , vol.95 , pp. 868-877
    • Weintraub, W.S.1    Jones, E.L.2    Morris, D.C.3
  • 31
    • 0029151208 scopus 로고
    • Predictors and sequelae of distal embolisation during saphenous vein graft intervention from the CAVEAT II Trial
    • Lefkovits J, Holmes DR, Califf RM, et al. Predictors and sequelae of distal embolisation during saphenous vein graft intervention from the CAVEAT II Trial. Circulation 1995;92:734-740.
    • (1995) Circulation , vol.92 , pp. 734-740
    • Lefkovits, J.1    Holmes, D.R.2    Califf, R.M.3
  • 32
    • 0028363502 scopus 로고
    • Palmaz Schatz stenting for treatment of focal vein graft stenosis: Immediate results and long term outcome
    • Piana RN, Moscucci M, Cohen DJ, et al. Palmaz Schatz stenting for treatment of focal vein graft stenosis: Immediate results and long term outcome. J Am Coll Cardiol 1994;23:1296-1304.
    • (1994) J Am Coll Cardiol , vol.23 , pp. 1296-1304
    • Piana, R.N.1    Moscucci, M.2    Cohen, D.J.3
  • 33
    • 0027971932 scopus 로고
    • Long term angiographic and clinical outcome after implantation of balloon expandable stents in aortocoronary saphenous vein grafts
    • Fenton SH, Fischman DL, Savage MP, et al. Long term angiographic and clinical outcome after implantation of balloon expandable stents in aortocoronary saphenous vein grafts. Am J Cardiol 1994;74:1187-1191.
    • (1994) Am J Cardiol , vol.74 , pp. 1187-1191
    • Fenton, S.H.1    Fischman, D.L.2    Savage, M.P.3
  • 34
    • 0029089448 scopus 로고
    • Immediate results and late outcomes after stent implantation in saphenous vein graft lesions: The multicenter US Palmaz-Schatz stent experience
    • Wong SC, Baim DS, Schatz RA, et al. Immediate results and late outcomes after stent implantation in saphenous vein graft lesions: The multicenter US Palmaz-Schatz stent experience. J Am Coll Cardiol 1995;29:704-712.
    • (1995) J Am Coll Cardiol , vol.29 , pp. 704-712
    • Wong, S.C.1    Baim, D.S.2    Schatz, R.A.3
  • 35
    • 0030198879 scopus 로고    scopus 로고
    • Long term clinical outcome after stent implantation in saphenous vein grafts
    • Jaegere PP, van Domburg RT, Feyter PJ, et al. Long term clinical outcome after stent implantation in saphenous vein grafts. J Am Coll Cardiol 1996;28:89-96.
    • (1996) J Am Coll Cardiol , vol.28 , pp. 89-96
    • Jaegere, P.P.1    Van Domburg, R.T.2    Feyter, P.J.3
  • 36
    • 0032786887 scopus 로고    scopus 로고
    • Creatine kinase MB enzyme elevation following successful saphenous vein graft intervention is associated with late mortality
    • Hong MK, Mehran R, Dangas G, et al. Creatine kinase MB enzyme elevation following successful saphenous vein graft intervention is associated with late mortality. Circulation 1999;100:2400-2405.
    • (1999) Circulation , vol.100 , pp. 2400-2405
    • Hong, M.K.1    Mehran, R.2    Dangas, G.3
  • 37
    • 9844257578 scopus 로고    scopus 로고
    • Stent placement compared with balloon angioplasty, for obstructed coronary bypass grafts
    • Savage MP, Douglas JS, Fischman DL, et al. Stent placement compared with balloon angioplasty, for obstructed coronary bypass grafts. N Engl J Med 1997;337:740-747.
    • (1997) N Engl J Med , vol.337 , pp. 740-747
    • Savage, M.P.1    Douglas, J.S.2    Fischman, D.L.3
  • 38
    • 0030727669 scopus 로고    scopus 로고
    • Long term follow up of a high risk cohort after stent implantation in saphenous vein grafts
    • Frimerman A, Rechavia E, Eigler N, et al. Long term follow up of a high risk cohort after stent implantation in saphenous vein grafts. J Am Coll Cardiol 1997;30:1277-1283.
    • (1997) J Am Coll Cardiol , vol.30 , pp. 1277-1283
    • Frimerman, A.1    Rechavia, E.2    Eigler, N.3
  • 39
    • 0030886774 scopus 로고    scopus 로고
    • Short and long term outcome of narrowed saphenous vein bypass graft: A comparison of Palmaz-Schatz stent, directional atherectomy and balloon angioplasty
    • Waksman R, Weintraub WS, Ghazzal Z, et al. Short and long term outcome of narrowed saphenous vein bypass graft: A comparison of Palmaz-Schatz stent, directional atherectomy and balloon angioplasty. Am Heart J 1997;134:274-281.
    • (1997) Am Heart J , vol.134 , pp. 274-281
    • Waksman, R.1    Weintraub, W.S.2    Ghazzal, Z.3
  • 40
    • 0038164591 scopus 로고    scopus 로고
    • Randomised evaluation of polytetrafluoroethylene-covered stents in saphenous vein grafts: The randomised evaluation of polytetrafluoroethylene covered stent in saphenous vein grafts (RECOVERS) trial
    • Stankovic G, Colombo A, Presbito P, et al. Randomised evaluation of polytetrafluoroethylene-covered stents in saphenous vein grafts: The randomised evaluation of polytetrafluoroethylene covered stent in saphenous vein grafts (RECOVERS) trial. Circulation 2003;108:37-42.
    • (2003) Circulation , vol.108 , pp. 37-42
    • Stankovic, G.1    Colombo, A.2    Presbito, P.3
  • 41
    • 10744222369 scopus 로고    scopus 로고
    • A randomized trial of polytetrafluoroethylene-membrane covered stents compared with conventional stents in aortocoronary saphenous vein grafts
    • Schächinger V, Hamm CW, Münzel T, et al. A randomized trial of polytetrafluoroethylene-membrane covered stents compared with conventional stents in aortocoronary saphenous vein grafts. J Am Coll Cardiol 2003;42:1360-1369.
    • (2003) J Am Coll Cardiol , vol.42 , pp. 1360-1369
    • Schächinger, V.1    Hamm, C.W.2    Münzel, T.3
  • 42
    • 0034711168 scopus 로고    scopus 로고
    • Treatment of aortocoronary vein graft lesions with membrane-covered stents: A multicenter surveillance trial
    • Baldus S, Koster R, Eisner M, et al. Treatment of aortocoronary vein graft lesions with membrane-covered stents: A multicenter surveillance trial. Circulation 2000;102:2024-2027.
    • (2000) Circulation , vol.102 , pp. 2024-2027
    • Baldus, S.1    Koster, R.2    Eisner, M.3
  • 43
    • 0034005501 scopus 로고    scopus 로고
    • Procedural results and intermediate clinical outcomes after multiple saphenous vein graft stenting
    • Bhargava B, Kornowski R, Mehran R, et al. Procedural results and intermediate clinical outcomes after multiple saphenous vein graft stenting. J Am Coll Cardiol 2000;35:389-397.
    • (2000) J Am Coll Cardiol , vol.35 , pp. 389-397
    • Bhargava, B.1    Kornowski, R.2    Mehran, R.3
  • 44
    • 0028686525 scopus 로고
    • Clinical experience with stent implantation in the treatment of saphenous vein graft lesions
    • Wong SC, Popma JJ, Kent KM, et al. Clinical experience with stent implantation in the treatment of saphenous vein graft lesions. J Interv Cardiol 1994;7:565-573.
    • (1994) J Interv Cardiol , vol.7 , pp. 565-573
    • Wong, S.C.1    Popma, J.J.2    Kent, K.M.3
  • 45
    • 0033931490 scopus 로고    scopus 로고
    • Polytetrafluoroethylene-covered stent for the treatment of narrowings in aortocoronary saphenous vein grafts
    • Briguori C, De Gregorio J, Nishida T, et al. Polytetrafluoroethylene- covered stent for the treatment of narrowings in aortocoronary saphenous vein grafts. Am J Cardiol 2000;86:343-346.
    • (2000) Am J Cardiol , vol.86 , pp. 343-346
    • Briguori, C.1    De Gregorio, J.2    Nishida, T.3
  • 46
    • 0035041121 scopus 로고    scopus 로고
    • Membrane-covered stents for saphenous vein graft lesions
    • Baldus S, Koster K, Reimers J, et al. Membrane-covered stents for saphenous vein graft lesions. Catheter Cardiovasc Interv 2001;53:1-4.
    • (2001) Catheter Cardiovasc Interv , vol.53 , pp. 1-4
    • Baldus, S.1    Koster, K.2    Reimers, J.3
  • 47
    • 0036296646 scopus 로고    scopus 로고
    • Results of the Jostent coronary stent graft implantation in various clinical settings: Procedural and follow up results
    • Gercken U, Lansky AJ, Buellaesfeld L, et al. Results of the Jostent coronary stent graft implantation in various clinical settings: Procedural and follow up results. Catheter Cardiovasc Interv 2002;56:353-360.
    • (2002) Catheter Cardiovasc Interv , vol.56 , pp. 353-360
    • Gercken, U.1    Lansky, A.J.2    Buellaesfeld, L.3
  • 49
    • 0035908781 scopus 로고    scopus 로고
    • Effects of pre-treatment with clopidogrel and aspirin followed by long-term therapy in patients undergoing percutaneous coronary intervention: The PCI-CURE trial
    • The CURE Investigators. Effects of pre-treatment with clopidogrel and aspirin followed by long-term therapy in patients undergoing percutaneous coronary intervention: The PCI-CURE trial. Lancet 2001;358:527-533.
    • (2001) Lancet , vol.358 , pp. 527-533
  • 50
    • 0037145863 scopus 로고    scopus 로고
    • Early and sustained dual oral antiplatelet therapy following percutaneous coronary intervention: A randomised controlled trial
    • The CREDO Investigators. Early and sustained dual oral antiplatelet therapy following percutaneous coronary intervention: A randomised controlled trial. J Am Med Assoc 2002;288:2411-2420.
    • (2002) J Am Med Assoc , vol.288 , pp. 2411-2420
  • 51
    • 0038287726 scopus 로고    scopus 로고
    • Elective placement of covered stents in native coronary arteries
    • Sovik E, Klow N-E, Brekke M, Stavnes S. Elective placement of covered stents in native coronary arteries. Acta Radiol 2003;44:294-301.
    • (2003) Acta Radiol , vol.44 , pp. 294-301
    • Sovik, E.1    Klow, N.-E.2    Brekke, M.3    Stavnes, S.4
  • 52
    • 0033781421 scopus 로고    scopus 로고
    • Six months clinical, angiographic and IVUS follow up after PTFE graft stent implantation in native coronary arteries
    • Lukito G, Vandergoten P, Jaspers E, et al. Six months clinical, angiographic and IVUS follow up after PTFE graft stent implantation in native coronary arteries. Acta Cardiol 2000;55:255-260.
    • (2000) Acta Cardiol , vol.55 , pp. 255-260
    • Lukito, G.1    Vandergoten, P.2    Jaspers, E.3
  • 53
    • 0038013963 scopus 로고    scopus 로고
    • Covered stent septal ablation for hypertrophic obstruction cardiomyopathy
    • Fifer MA, Yoerger DM, Picard MH, et al. Covered stent septal ablation for hypertrophic obstruction cardiomyopathy. Circulation 2003;107:3248,3249.
    • (2003) Circulation , vol.107 , pp. 3248
    • Fifer, M.A.1    Yoerger, D.M.2    Picard, M.H.3
  • 54
    • 0030227026 scopus 로고    scopus 로고
    • Patency and tissue response related to two types of polytetrafluoroethylene-covered stents in the dog
    • Dolmatch BL, Tio FO, Li XD, et al. Patency and tissue response related to two types of polytetrafluoroethylene-covered stents in the dog. J Vasc Interv Radiol 1996;7:641-649.
    • (1996) J Vasc Interv Radiol , vol.7 , pp. 641-649
    • Dolmatch, B.L.1    Tio, F.O.2    Li, X.D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.