메뉴 건너뛰기




Volumn 48, Issue 3, 1999, Pages 304-307

Repair of left anterior descending coronary artery perforation by Magic Wallstent implantation

Author keywords

Coronary artery perforation; Magic Wallstent; Percutaneous balloon angioplasty; Stent

Indexed keywords

ACETYLSALICYLIC ACID; CREATINE KINASE; TICLOPIDINE;

EID: 0032734187     PISSN: 15221946     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1522-726X(199911)48:3<304::AID-CCD16>3.0.CO;2-9     Document Type: Article
Times cited : (7)

References (13)
  • 1
    • 0028307660 scopus 로고
    • Perforations after percutaneous coronary interventions: Clinical, angiographic and therapeutic observations
    • Ajuni SC, Glazier S, Blakenship L, O'Neil WW, Safian RD. Perforations after percutaneous coronary interventions: clinical, angiographic and therapeutic observations. Cathet Cardiovasc Diagn 1994;32:206-212.
    • (1994) Cathet Cardiovasc Diagn , vol.32 , pp. 206-212
    • Ajuni, S.C.1    Glazier, S.2    Blakenship, L.3    O'Neil, W.W.4    Safian, R.D.5
  • 3
    • 4243361997 scopus 로고    scopus 로고
    • Coronary perforations:a persistent problem in interventions
    • Shah MS, Raymond RE. Coronary perforations:a persistent problem in interventions. J Am Coll Cardiol 1998;31(Suppl A):493A.
    • (1998) J Am Coll Cardiol , vol.31 , Issue.SUPPL. A
    • Shah, M.S.1    Raymond, R.E.2
  • 5
    • 0027380599 scopus 로고
    • Use of an intracoronary stent to control intrapericardial bleeding during coronary artery rupture complicating coronary angioplasty
    • Thomas MR, Wainwright RJ. Use of an intracoronary stent to control intrapericardial bleeding during coronary artery rupture complicating coronary angioplasty. Cathet Cardiovasc Diagn 1993; 30:169-172.
    • (1993) Cathet Cardiovasc Diagn , vol.30 , pp. 169-172
    • Thomas, M.R.1    Wainwright, R.J.2
  • 6
    • 0031787763 scopus 로고    scopus 로고
    • Repair of coronary artery perforation after rotastenting by implantation of the Jostent covered stent
    • Ramsdale DR, Mushawhar SS, Morris JL. Repair of coronary artery perforation after rotastenting by implantation of the Jostent covered stent. Cathet Cardiovasc Diagn 1998;45:310-313.
    • (1998) Cathet Cardiovasc Diagn , vol.45 , pp. 310-313
    • Ramsdale, D.R.1    Mushawhar, S.S.2    Morris, J.L.3
  • 9
    • 0029103204 scopus 로고
    • Management of coronary artery rupture: Covered stent or microcoil embolization
    • Dorros G, Jain A, Kumar K. Management of coronary artery rupture: covered stent or microcoil embolization. Cathet Cardiovasc Diagn 1995;36:148-154.
    • (1995) Cathet Cardiovasc Diagn , vol.36 , pp. 148-154
    • Dorros, G.1    Jain, A.2    Kumar, K.3
  • 11
    • 29444433652 scopus 로고    scopus 로고
    • Delayed coronary perforation after the use of high-speed rotational atherectomy
    • Ng W, Wong CK. Delayed coronary perforation after the use of high-speed rotational atherectomy. J Invasive Cardiol 1998;10:98-100.
    • (1998) J Invasive Cardiol , vol.10 , pp. 98-100
    • Ng, W.1    Wong, C.K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.