-
1
-
-
0036365842
-
Single-strand ligament reconstruction of the medial collateral ligament restores valgus elbow stability
-
Armstrong A.D., Dunning C.E., Faber K.J., Johnson J.A., and King G.J. Single-strand ligament reconstruction of the medial collateral ligament restores valgus elbow stability. J Shoulder Elbow Surg 11 (2002) 65-71
-
(2002)
J Shoulder Elbow Surg
, vol.11
, pp. 65-71
-
-
Armstrong, A.D.1
Dunning, C.E.2
Faber, K.J.3
Johnson, J.A.4
King, G.J.5
-
2
-
-
0034269243
-
Radiographic determinants of the elbow rotation axis. experimental identification and quantitative validation
-
Bottlang M., O'Rourke M.R., Madey S.M., Steyers C.M., Marsh J.L., and Brown T.D. Radiographic determinants of the elbow rotation axis. experimental identification and quantitative validation. J Orthop Res 18 (2000) 821-828
-
(2000)
J Orthop Res
, vol.18
, pp. 821-828
-
-
Bottlang, M.1
O'Rourke, M.R.2
Madey, S.M.3
Steyers, C.M.4
Marsh, J.L.5
Brown, T.D.6
-
3
-
-
0035724897
-
Precision of ACL tunnel placement using traditional and robotic techniques
-
Burkart A., Debski R.E., McMahon P.J., Rudy T., Fu F.H., Musahl V., et al. Precision of ACL tunnel placement using traditional and robotic techniques. Comput Aided Surg 6 (2001) 270-278
-
(2001)
Comput Aided Surg
, vol.6
, pp. 270-278
-
-
Burkart, A.1
Debski, R.E.2
McMahon, P.J.3
Rudy, T.4
Fu, F.H.5
Musahl, V.6
-
5
-
-
0038441549
-
Variation in the position and orientation of the elbow flexion axis
-
Ericson A., Arndt A., Stark A., Wretenberg P., and Lundberg A. Variation in the position and orientation of the elbow flexion axis. J Bone Joint Surg Br 85 (2003) 538-544
-
(2003)
J Bone Joint Surg Br
, vol.85
, pp. 538-544
-
-
Ericson, A.1
Arndt, A.2
Stark, A.3
Wretenberg, P.4
Lundberg, A.5
-
6
-
-
0023026023
-
A critical analysis of alignment factors affecting functional outcome in total elbow arthroplasty
-
Figgie III H.E., Inglis A.E., and Mow C. A critical analysis of alignment factors affecting functional outcome in total elbow arthroplasty. J Arthroplasty 1 (1986) 169-173
-
(1986)
J Arthroplasty
, vol.1
, pp. 169-173
-
-
Figgie III, H.E.1
Inglis, A.E.2
Mow, C.3
-
7
-
-
0032744485
-
Metallic radial head arthroplasty improves valgus stability of the elbow
-
King G.J., Zarzour Z.D., Rath D.A., Dunning C.E., Patterson S.D., and Johnson J.A. Metallic radial head arthroplasty improves valgus stability of the elbow. Clin Orthop Relat Res (1999) 114-125
-
(1999)
Clin Orthop Relat Res
, pp. 114-125
-
-
King, G.J.1
Zarzour, Z.D.2
Rath, D.A.3
Dunning, C.E.4
Patterson, S.D.5
Johnson, J.A.6
-
8
-
-
0019522518
-
Kinematics of the elbow
-
London J.T. Kinematics of the elbow. J Bone Joint Surg Am 63 (1981) 529-535
-
(1981)
J Bone Joint Surg Am
, vol.63
, pp. 529-535
-
-
London, J.T.1
-
9
-
-
0033629631
-
Hinged external fixation of the elbow. optimal axis alignment to minimize motion resistance
-
Madey S.M., Bottlang M., Steyers C.M., Marsh J.L., and Brown T.D. Hinged external fixation of the elbow. optimal axis alignment to minimize motion resistance. J Orthop Trauma 14 (2000) 41-47
-
(2000)
J Orthop Trauma
, vol.14
, pp. 41-47
-
-
Madey, S.M.1
Bottlang, M.2
Steyers, C.M.3
Marsh, J.L.4
Brown, T.D.5
-
10
-
-
0006590883
-
Semiconstrained elbow replacement arthroplasty. rationale and surgical technique
-
Morrey B.F. (Ed), Saunders, Philadelphia
-
Morrey B.F. Semiconstrained elbow replacement arthroplasty. rationale and surgical technique. In: Morrey B.F. (Ed). The elbow and its disorders (2000), Saunders, Philadelphia 617-630
-
(2000)
The elbow and its disorders
, pp. 617-630
-
-
Morrey, B.F.1
-
11
-
-
0017143154
-
Passive motion of the elbow joint
-
Morrey B.F., and Chao E.Y. Passive motion of the elbow joint. J Bone Joint Surg Am 58 (1976) 501-508
-
(1976)
J Bone Joint Surg Am
, vol.58
, pp. 501-508
-
-
Morrey, B.F.1
Chao, E.Y.2
-
12
-
-
0001388974
-
External fixators of the elbow
-
Morrey B.F. (Ed), Saunders, Philadelphia
-
Morrey B.F., and Hotchkiss R.N. External fixators of the elbow. In: Morrey B.F. (Ed). The elbow and its disorders (2000), Saunders, Philadelphia 457-467
-
(2000)
The elbow and its disorders
, pp. 457-467
-
-
Morrey, B.F.1
Hotchkiss, R.N.2
-
13
-
-
0029089828
-
Loose-hinge total elbow arthroplasty. An experimental study of the effects of implant alignment on three-dimensional elbow kinematics
-
Schuind F., O'Driscoll S., Korinek S., An K.N., and Morrey B.F. Loose-hinge total elbow arthroplasty. An experimental study of the effects of implant alignment on three-dimensional elbow kinematics. J Arthroplasty 10 (1995) 670-678
-
(1995)
J Arthroplasty
, vol.10
, pp. 670-678
-
-
Schuind, F.1
O'Driscoll, S.2
Korinek, S.3
An, K.N.4
Morrey, B.F.5
-
14
-
-
0033106432
-
Determination of the optimal elbow axis for evaluation of placement of prostheses
-
Stokdijk M., Meskers C.G., Veeger H.E., de Boer Y.A., and Rozing P.M. Determination of the optimal elbow axis for evaluation of placement of prostheses. Clin Biomech (Bristol, Avon) 14 (1999) 177-184
-
(1999)
Clin Biomech (Bristol, Avon)
, vol.14
, pp. 177-184
-
-
Stokdijk, M.1
Meskers, C.G.2
Veeger, H.E.3
de Boer, Y.A.4
Rozing, P.M.5
|