메뉴 건너뛰기




Volumn 14, Issue 1, 2000, Pages 41-47

Hinged external fixation of the elbow: Optimal axis alignment to minimize motion resistance

Author keywords

Elbow kinematics; External fixation; Fixator alignment; Hinged fixation; Screw displacement axis

Indexed keywords

ARTICLE; CADAVER; ELBOW; EXTERNAL FIXATOR; HUMAN; JOINT CHARACTERISTICS AND FUNCTIONS; PHYSIOLOGY;

EID: 0033629631     PISSN: 08905339     EISSN: None     Source Type: Journal    
DOI: 10.1097/00005131-200001000-00009     Document Type: Article
Times cited : (48)

References (36)
  • 1
    • 0023847773 scopus 로고
    • Non-union of fractures of the distal end of the humerus
    • Ackermann G, Jupiter JB. Non-union of fractures of the distal end of the humerus. J Bone Joint Surg [Am] 1988;70A:75-83.
    • (1988) J Bone Joint Surg [Am] , vol.70 A , pp. 75-83
    • Ackermann, G.1    Jupiter, J.B.2
  • 2
    • 0022542187 scopus 로고
    • The effect of partial removal of proximal ulna on elbow constraint
    • An KN, Morrey BF, Chao EYS. The effect of partial removal of proximal ulna on elbow constraint. Clin Orthop Rel Res 1986;209: 270-279.
    • (1986) Clin Orthop Rel Res , vol.209 , pp. 270-279
    • An, K.N.1    Morrey, B.F.2    Chao, E.Y.S.3
  • 3
    • 0003438652 scopus 로고
    • Berlin, Springer-Verlag
    • Beggs JS. Kinematics. Berlin, Springer-Verlag, 1983.
    • (1983) Kinematics
    • Beggs, J.S.1
  • 4
    • 0026597929 scopus 로고
    • Surgical management of chronic medial elbow instability
    • Bennet JB, Green MS, Tullos HS. Surgical management of chronic medial elbow instability. Clin Orthop Rel Res 1992;278:62-68.
    • (1992) Clin Orthop Rel Res , vol.278 , pp. 62-68
    • Bennet, J.B.1    Green, M.S.2    Tullos, H.S.3
  • 5
    • 0032101873 scopus 로고    scopus 로고
    • Factors influencing accuracy of screw displacement axis detection with a DC-based electromagnetic motion tracking system
    • Bottlang M, Marsh JL, Brown TD. Factors influencing accuracy of screw displacement axis detection with a DC-based electromagnetic motion tracking system. J Biomech Eng 1998;120:431-435.
    • (1998) J Biomech Eng , vol.120 , pp. 431-435
    • Bottlang, M.1    Marsh, J.L.2    Brown, T.D.3
  • 6
    • 0039598692 scopus 로고    scopus 로고
    • Assessment of elbow joint kinematics in passive motion via electromagnetic motion tracking
    • in press
    • Bottlang M, Madey SM, Steyers CM, Marsh JL, Brown TD. Assessment of elbow joint kinematics in passive motion via electromagnetic motion tracking. J Orthop Res 1999 (in press).
    • (1999) J Orthop Res
    • Bottlang, M.1    Madey, S.M.2    Steyers, C.M.3    Marsh, J.L.4    Brown, T.D.5
  • 7
    • 0023147353 scopus 로고
    • Results of treatment of fracture-dislocations of the elbow
    • Broberg MA, Morrey BF. Results of treatment of fracture-dislocations of the elbow. Clin Orthop Rel Res 1987;216:109-199.
    • (1987) Clin Orthop Rel Res , vol.216 , pp. 109-199
    • Broberg, M.A.1    Morrey, B.F.2
  • 8
    • 0017800420 scopus 로고
    • Three-dimensional rotation of the elbow
    • Chao EYS, Morrey BF. Three-dimensional rotation of the elbow. J Biomech 1978;11:57-73.
    • (1978) J Biomech , vol.11 , pp. 57-73
    • Chao, E.Y.S.1    Morrey, B.F.2
  • 9
    • 0028919989 scopus 로고
    • Use of distraction arthroplasty in unstable fracture dislocations of the elbow
    • Cobb TK, Morrey BF. Use of distraction arthroplasty in unstable fracture dislocations of the elbow. Clin Orthop Rel Res 1995;312: 201-210.
    • (1995) Clin Orthop Rel Res , vol.312 , pp. 201-210
    • Cobb, T.K.1    Morrey, B.F.2
  • 11
    • 0023113605 scopus 로고
    • Biomechanical basis for elbow, hinge-distractor design
    • Deland JT, Garg A, Walker PS. Biomechanical basis for elbow, hinge-distractor design. Clin Orthop Rel Res 1987;215:303-312.
    • (1987) Clin Orthop Rel Res , vol.215 , pp. 303-312
    • Deland, J.T.1    Garg, A.2    Walker, P.S.3
  • 13
  • 15
    • 0019522518 scopus 로고
    • Kinematics of the elbow
    • London JT. Kinematics of the elbow. J Bone Joint Surg [Am] 1981;63A:529-535.
    • (1981) J Bone Joint Surg [Am] , vol.63 A , pp. 529-535
    • London, J.T.1
  • 17
    • 0030175849 scopus 로고    scopus 로고
    • Accuracy of an electromagnetic tracking device: A study of the optimal operating range and metal interference
    • Milne AD, Chess DG, Johnson JA, King GJW. Accuracy of an electromagnetic tracking device: a study of the optimal operating range and metal interference. J Biomech 1996;29:791-793.
    • (1996) J Biomech , vol.29 , pp. 791-793
    • Milne, A.D.1    Chess, D.G.2    Johnson, J.A.3    King, G.J.W.4
  • 18
    • 0018371834 scopus 로고
    • Biomechanical study of the elbow following excision of the radial head
    • Morrey BF, Chao EYS, Hui FC. Biomechanical study of the elbow following excision of the radial head. J Bone Joint Surg [Am] 1979; 61A:63-68.
    • (1979) J Bone Joint Surg [Am] , vol.61 A , pp. 63-68
    • Morrey, B.F.1    Chao, E.Y.S.2    Hui, F.C.3
  • 20
    • 0020550913 scopus 로고
    • Articular and ligamentous contributions to the stability of the elbow joint
    • Morrey BF, An KN. Articular and ligamentous contributions to the stability of the elbow joint. Am J Sports Med 1983;11:315-319.
    • (1983) Am J Sports Med , vol.11 , pp. 315-319
    • Morrey, B.F.1    An, K.N.2
  • 21
    • 0022297884 scopus 로고
    • Functional anatomy of the ligaments of the elbow
    • Morrey BF, An KN. Functional anatomy of the ligaments of the elbow. Clin Orthop Rel Res 1985;201:84-90.
    • (1985) Clin Orthop Rel Res , vol.201 , pp. 84-90
    • Morrey, B.F.1    An, K.N.2
  • 22
    • 0025319779 scopus 로고
    • Post-traumatic contracture of the elbow
    • Morrey BF. Post-traumatic contracture of the elbow. J Bone Joint Surg [Am] 1990;72A:601-618.
    • (1990) J Bone Joint Surg [Am] , vol.72 A , pp. 601-618
    • Morrey, B.F.1
  • 23
    • 0026331754 scopus 로고
    • Valgus stability of the elbow. A definition of primary and secondary constraints
    • Morrey BF, Tanaka S, An KN. Valgus stability of the elbow. A definition of primary and secondary constraints. Clin Orthop Rel Res 1991;265:187-195.
    • (1991) Clin Orthop Rel Res , vol.265 , pp. 187-195
    • Morrey, B.F.1    Tanaka, S.2    An, K.N.3
  • 24
    • 0027270946 scopus 로고
    • Distraction arthroplasty
    • Morrey BF. Distraction arthroplasty. Clin Orthop Rel Res 1993; 293:46-54.
    • (1993) Clin Orthop Rel Res , vol.293 , pp. 46-54
    • Morrey, B.F.1
  • 25
    • 0028900724 scopus 로고
    • Current concepts in the treatment of fractures of the radial head, the olecranon, and the coronoid
    • Morrey BF. Current concepts in the treatment of fractures of the radial head, the olecranon, and the coronoid. J Bone Joint Surg [Am] 1995;77A:316-327.
    • (1995) J Bone Joint Surg [Am] , vol.77 A , pp. 316-327
    • Morrey, B.F.1
  • 26
    • 0026772639 scopus 로고
    • Anatomy of the ulnar part of the lateral collateral ligament of the elbow
    • O'Driscoll SW, Horii E, Morrey BF, Carmichael SW. Anatomy of the ulnar part of the lateral collateral ligament of the elbow. Clin Anal 1992;5:293-303.
    • (1992) Clin Anal , vol.5 , pp. 293-303
    • O'Driscoll, S.W.1    Horii, E.2    Morrey, B.F.3    Carmichael, S.W.4
  • 28
    • 0018174248 scopus 로고
    • Dislocation of the elbow joint
    • Protzman RR. Dislocation of the elbow joint. J Bone Joint Surg [Am] 1978;60A:539-541.
    • (1978) J Bone Joint Surg [Am] , vol.60 A , pp. 539-541
    • Protzman, R.R.1
  • 30
    • 0018863951 scopus 로고
    • Biomechanics of elbow instability: The role of the medial collateral ligament
    • Schwab GH, Bennet JB, Woods GW, Tullos HS. Biomechanics of elbow instability: the role of the medial collateral ligament. Clin Orthop Rel Res 1980;146:42-51.
    • (1980) Clin Orthop Rel Res , vol.146 , pp. 42-51
    • Schwab, G.H.1    Bennet, J.B.2    Woods, G.W.3    Tullos, H.S.4
  • 32
    • 0023227869 scopus 로고
    • The stability of the elbow following excision of the radial head and transsection of the annular ligament
    • Sojbjerg JO, Ovesen MDJ, Gundorf CE. The stability of the elbow following excision of the radial head and transsection of the annular ligament. Arch Orthop Trauma Surg 1987;106:248-250.
    • (1987) Arch Orthop Trauma Surg , vol.106 , pp. 248-250
    • Sojbjerg, J.O.1    Ovesen, M.D.J.2    Gundorf, C.E.3
  • 33
    • 0023229931 scopus 로고
    • Experimental elbow instability after transsection of the medial collateral ligament
    • Sojbjerg JO, Ovesen MDJ, Nielson S. Experimental elbow instability after transsection of the medial collateral ligament. Clin Orthop Rel Res 1987;218:186-190.
    • (1987) Clin Orthop Rel Res , vol.218 , pp. 186-190
    • Sojbjerg, J.O.1    Ovesen, M.D.J.2    Nielson, S.3
  • 34
    • 0016809923 scopus 로고
    • Restoration of function in the knee and elbow with a hinge-distractor apparatus
    • Volkov MV, Oganesian OV. Restoration of function in the knee and elbow with a hinge-distractor apparatus. J Bone Joint Surg [Am] 1975;57A:591-600.
    • (1975) J Bone Joint Surg [Am] , vol.57 A , pp. 591-600
    • Volkov, M.V.1    Oganesian, O.V.2
  • 35
    • 0028146707 scopus 로고
    • Biomechanics of the elbow and forearm
    • Werner FW, An KN. Biomechanics of the elbow and forearm. Hand Clin 1994;10:357-373.
    • (1994) Hand Clin , vol.10 , pp. 357-373
    • Werner, F.W.1    An, K.N.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.