메뉴 건너뛰기




Volumn 26, Issue 10, 2006, Pages 67-72

Study on transformer protection principle based on equivalent circuit equilibrium equation

Author keywords

Equivalent circuit equilibrium equation; Inrush current; Internal fault; Leakage inductance; Least square; Mutual flux; Power system; Transformer protection

Indexed keywords

ALGORITHMS; EQUIVALENT CIRCUITS; LEAST SQUARES APPROXIMATIONS; PHASE EQUILIBRIA; TRANSFORMER PROTECTION;

EID: 33745757229     PISSN: 02588013     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (50)

References (16)
  • 1
    • 0035481860 scopus 로고    scopus 로고
    • A current-based solution for transformer differential protection - Part I: Problem statement
    • Armando Guzman, Stan Zocholl, Gabriel Benmouyal, et al. A Current-Based Solution for Transformer Differential Protection - Part I: Problem Statement[J]. IEEE Transaction On Power Delivery, 2001, 16(10): 485-491.
    • (2001) IEEE Transaction On Power Delivery , vol.16 , Issue.10 , pp. 485-491
    • Guzman, A.1    Zocholl, S.2    Benmouyal, G.3
  • 2
    • 0036814761 scopus 로고    scopus 로고
    • A Current-based solution for transformer differential protection - Part II: Relay description and evaluation
    • Armando Guzman, Stan Zocholl, Hector J Altuve. A Current-based solution for transformer differential protection -part ii: relay description and evaluation[J]. IEEE Transaction on Power Delivery, 2002, 17(4): 886-893.
    • (2002) IEEE Transaction on Power Delivery , vol.17 , Issue.4 , pp. 886-893
    • Guzman, A.1    Zocholl, S.2    Altuve, H.J.3
  • 3
    • 0032285197 scopus 로고    scopus 로고
    • Protection based on wave comparison
    • He Benteng, Xu Xidong. Protection based on wave comparison[J]. Proceeding of the CSEE, 1998, 18(6): 395-398, 404.
    • (1998) Proceeding of the CSEE , vol.18 , Issue.6
    • He, B.1    Xu, X.2
  • 4
    • 0033172127 scopus 로고    scopus 로고
    • A novel scheme to discriminate inrush current and fault current based on integrating the waveform
    • Jiao Shaohua, Liu Wanshun. A novel scheme to discriminate inrush current and fault current based on integrating the waveform[J]. Proceeding of the CSEE, 1999, 19(8): 35-38.
    • (1999) Proceeding of the CSEE , vol.19 , Issue.8 , pp. 35-38
    • Jiao, S.1    Liu, W.2
  • 5
    • 0033140764 scopus 로고    scopus 로고
    • A new principle of discrimination between inrush current and fault current of transformer based on wavelet
    • Jiao Shaohua, Liu Wanshun, Liu Jianfei, et al. A new principle of discrimination between inrush current and fault current of transformer based on wavelet[J]. Proceeding of the CSEE, 1999, 19(7): 1-5, 76.
    • (1999) Proceeding of the CSEE , vol.19 , Issue.7
    • Jiao, S.1    Liu, W.2    Liu, J.3
  • 6
    • 0031632133 scopus 로고    scopus 로고
    • Computerized transformer protection based on artificial neural network
    • Duan Yuqian, He Jiali, He Jihong. Computerized transformer protection based on artificial neural network[J]. Proceeding of the CSEE, 1998, 18(3): 190-194.
    • (1998) Proceeding of the CSEE , vol.18 , Issue.3 , pp. 190-194
    • Duan, Y.1    He, J.2    He, J.3
  • 7
    • 0032262468 scopus 로고    scopus 로고
    • Identify the fault current and inrush current of a transformer using the fuzzy degree of nearness
    • Liang Guojian, Liang Guanan. Identify the fault current and inrush current of a transformer using the fuzzy degree of nearness[J]. Proceeding of the CSEE, 1998, 18(5): 310-314.
    • (1998) Proceeding of the CSEE , vol.18 , Issue.5 , pp. 310-314
    • Liang, G.1    Liang, G.2
  • 8
    • 19644376060 scopus 로고    scopus 로고
    • Distinguish between inrush and internal fault of transformer based on adaptive wavelet neural network
    • Li Haifeng, Wang Gang, Li Xiaohua, et al. Distinguish between inrush and internal fault of transformer based on adaptive wavelet neural network[J]. Proceeding of the CSEE, 2005, 25(7): 144-150.
    • (2005) Proceeding of the CSEE , vol.25 , Issue.7 , pp. 144-150
    • Li, H.1    Wang, G.2    Li, X.3
  • 9
    • 85009301869 scopus 로고    scopus 로고
    • Chinese source
  • 10
    • 0031176131 scopus 로고    scopus 로고
    • Power differential method for discrimination between fault and magnetizing inrush current in transformer
    • Yabe K. Power differential method for discrimination between fault and magnetizing inrush current in transformer[J]. IEEE Transaction on Power Delivery, 1997, 12(3): 1109-1118.
    • (1997) IEEE Transaction on Power Delivery , vol.12 , Issue.3 , pp. 1109-1118
    • Yabe, K.1
  • 11
    • 0020846003 scopus 로고
    • A new computer-based flux-restrained current-differential relay for power transformer protection
    • Phadke A G, Thorp J S. A new computer-based flux-restrained current-differential relay for power transformer protection[J]. IEEE Transactions on Power Apparatus and Systems, 1983, 102(11): 3624-3629.
    • (1983) IEEE Transactions on Power Apparatus and Systems , vol.102 , Issue.11 , pp. 3624-3629
    • Phadke, A.G.1    Thorp, J.S.2
  • 12
    • 0034922687 scopus 로고    scopus 로고
    • Transformer inrushdetected by the variation of magnetizing impedance
    • Zong Hongliang, Jin Huafeng, Zhu Zhenfei, et al. Transformer inrushdetected by the variation of magnetizing impedance[J]. Proceeding of the CSEE, 2001, 21(7): 91-94.
    • (2001) Proceeding of the CSEE , vol.21 , Issue.7 , pp. 91-94
    • Zong, H.1    Jin, H.2    Zhu, Z.3
  • 13
    • 0024087827 scopus 로고
    • Digital protection method for power transformers based on an equivalent circuit composed of inverse inductance
    • Inagaju K, Higaju M, Matsyu Y, et al. Digital protection method for power transformers based on an equivalent circuit composed of inverse inductance[J]. IEEE Transaction on Power Delivery, 1988, 3(4): 1501-1508.
    • (1988) IEEE Transaction on Power Delivery , vol.3 , Issue.4 , pp. 1501-1508
    • Inagaju, K.1    Higaju, M.2    Matsyu, Y.3
  • 14
    • 1642393176 scopus 로고    scopus 로고
    • Study on the novel transformer protection principle based on the transformer model
    • Wang Zengping, Xu Yan, Wang Xue, et al. Study on the novel transformer protection principle based on the transformer model[J]. Proceeding of the CSEE, 2003, 23(12): 54-58.
    • (2003) Proceeding of the CSEE , vol.23 , Issue.12 , pp. 54-58
    • Wang, Z.1    Xu, Y.2    Wang, X.3
  • 15
    • 14944372510 scopus 로고    scopus 로고
    • A novel transformer model based protective princeple for transformer and its criteria
    • Han Zhengqing, Gao Shibin, Li Qunzhan. A novel transformer model based protective princeple for transformer and its criteria[J]. Power System Technology, 2005, 29(5): 67-71.
    • (2005) Power System Technology , vol.29 , Issue.5 , pp. 67-71
    • Han, Z.1    Gao, S.2    Li, Q.3
  • 16
    • 85009310628 scopus 로고    scopus 로고
    • Chinese source


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.