메뉴 건너뛰기




Volumn 29, Issue 5, 2005, Pages 67-71

A novel transformer model based protective principle for transformer and its criteria

Author keywords

Magnetizing inrush current; Setting rules; Transformer model; Transformer protection

Indexed keywords

COMPUTER SIMULATION; ELECTRIC CURRENTS; ELECTRIC FAULT CURRENTS; MAGNETIZATION; RELAY PROTECTION; TRANSFORMER WINDINGS;

EID: 14944372510     PISSN: 10003673     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (11)

References (14)
  • 1
    • 0036814761 scopus 로고    scopus 로고
    • A current-based solution for transformer differential protection - Part II: Relay description and evaluation
    • Guzman A, Zocholl S, Benmouyal G et al. A current-based solution for transformer differential protection - part II: relay description and evaluation[J]. IEEE Transactions on Power Delivery, 2002, 17(4): 886-894.
    • (2002) IEEE Transactions on Power Delivery , vol.17 , Issue.4 , pp. 886-894
    • Guzman, A.1    Zocholl, S.2    Benmouyal, G.3
  • 2
    • 0033706932 scopus 로고    scopus 로고
    • Modeling and simulation of the power transformer faults and related protective relay behavior
    • Kezunovic M, Guo Y. Modeling and simulation of the power transformer faults and related protective relay behavior[J]. IEEE Transactions on Power Delivery, 2000, 15(1): 44-50.
    • (2000) IEEE Transactions on Power Delivery , vol.15 , Issue.1 , pp. 44-50
    • Kezunovic, M.1    Guo, Y.2
  • 3
    • 0012181121 scopus 로고    scopus 로고
    • A fuzzy set theory based protection algorithm for turn to turn fault of power transformer and its simulation
    • Huang Dengfeng, Yu Weiyong. A fuzzy set theory based protection algorithm for turn to turn fault of power transformer and its simulation[J]. Power System Technology, 2002, 26(1): 11-14.
    • (2002) Power System Technology , vol.26 , Issue.1 , pp. 11-14
    • Huang, D.1    Yu, W.2
  • 4
    • 14944339674 scopus 로고    scopus 로고
    • Power transformer differential protection with integration of multi-criteria
    • Yang Jingchao, Yin Xianggen, Chen Deshu et al. Power transformer differential protection with integration of multi-criteria[J]. Power System Technology, 2003, 27(10): 66-71.
    • (2003) Power System Technology , vol.27 , Issue.10 , pp. 66-71
    • Yang, J.1    Yin, X.2    Chen, D.3
  • 5
    • 0036814272 scopus 로고    scopus 로고
    • Studies for identification of the inrush based on improved correlation algorithm
    • Lin X N, Liu P, Malik O P. Studies for identification of the inrush based on improved correlation algorithm[J]. IEEE Transactions on Power Delivery, 2002, 17(4): 901-907.
    • (2002) IEEE Transactions on Power Delivery , vol.17 , Issue.4 , pp. 901-907
    • Lin, X.N.1    Liu, P.2    Malik, O.P.3
  • 6
    • 14944349749 scopus 로고    scopus 로고
    • A new algorithm to prevent misoperation of transformer differential protection based on principle of wavelet transform
    • Li Guicun, Liu Wanshun, Jia Qingquan et al. A new algorithm to prevent misoperation of transformer differential protection based on principle of wavelet transform[J]. Power System Technology, 2001, 25(7): 48-55.
    • (2001) Power System Technology , vol.25 , Issue.7 , pp. 48-55
    • Li, G.1    Liu, W.2    Jia, Q.3
  • 8
    • 14944372091 scopus 로고    scopus 로고
    • Chinese source
  • 9
    • 0020846003 scopus 로고
    • A new computer-based flux-restrained current-differential relay for power transformer protection
    • Phadke A G, Thorp J S. A new computer-based flux-restrained current-differential relay for power transformer protection[J]. IEEE Transactions on Power Apparatus and Systems, 1983, 102(11): 3624-3629.
    • (1983) IEEE Transactions on Power Apparatus and Systems , vol.102 , Issue.11 , pp. 3624-3629
    • Phadke, A.G.1    Thorp, J.S.2
  • 10
    • 0037057046 scopus 로고    scopus 로고
    • Distinguish inrush currents for transformers using frequency characteristic of instantaneous excitation inductance
    • Ge Baoming, Su Pengsheng, Wang Xiangheng et al. Distinguish inrush currents for transformers using frequency characteristic of instantaneous excitation inductance[J]. Automation of Electric Power Systems, 2002, 26(17): 35-40.
    • (2002) Automation of Electric Power Systems , vol.26 , Issue.17 , pp. 35-40
    • Ge, B.1    Su, P.2    Wang, X.3
  • 11
    • 0034922687 scopus 로고    scopus 로고
    • Transformer inrush detected by the variation of magnetizing impedance
    • Zong Hongliang, Jin Huafeng, Zhu Zhenfei et al. Transformer inrush detected by the variation of magnetizing impedance[J]. Proceedings of the CSEE, 2001, 21(7): 91-94.
    • (2001) Proceedings of the CSEE , vol.21 , Issue.7 , pp. 91-94
    • Zong, H.1    Jin, H.2    Zhu, Z.3
  • 12
    • 0024087827 scopus 로고
    • Digital protection method for power transformers based on an equivalent circuit composed of inverse inductance
    • Inagaki K, Higaki M, Matsui Y et al. Digital protection method for power transformers based on an equivalent circuit composed of inverse inductance[J]. IEEE Transactions on Power Delivery, 1988, 3(4): 1501-1510.
    • (1988) IEEE Transactions on Power Delivery , vol.3 , Issue.4 , pp. 1501-1510
    • Inagaki, K.1    Higaki, M.2    Matsui, Y.3
  • 13
    • 14944386063 scopus 로고    scopus 로고
    • Chinese source
  • 14
    • 1642393176 scopus 로고    scopus 로고
    • Study on the novel transformer protection principle based on the transformer model
    • Wang Zengping, Xu Yan, Wang Xue et al. Study on the novel transformer protection principle based on the transformer model[J]. Proceedings of the CSEE, 2003, 23(12): 54-58.
    • (2003) Proceedings of the CSEE , vol.23 , Issue.12 , pp. 54-58
    • Wang, Z.1    Xu, Y.2    Wang, X.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.