A calibration method for misaligned scanner geometry in cone-beam computed tomography

Author keywords

Calibration; Cone beam CT; Geometric misalignment

Indexed keywords

CALIBRATION; COMPUTATIONAL GEOMETRY; COMPUTER SIMULATION; IMAGE PROCESSING; IMAGE RECONSTRUCTION; PARAMETER ESTIMATION;

EID: 33745698888     PISSN: 09638695     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ndteint.2006.03.002     Document Type: Article
Times cited : (69)

References (9)
  • 2
    • 0025349536 scopus 로고
    • Estimation of geometrical parameters and collimator evaluation for cone beam tomography
    • Gullberg G.T., Tsui B.M.W., Crawford C.R., Ballard J.G., and Hagius J.T. Estimation of geometrical parameters and collimator evaluation for cone beam tomography. Med Phys 17 2 (1990) 264-272
    • (1990) Med Phys , vol.17 , Issue.2 , pp. 264-272
    • Gullberg, G.T.1    Tsui, B.M.W.2    Crawford, C.R.3    Ballard, J.G.4    Hagius, J.T.5
  • 3
    • 0027175720 scopus 로고
    • Determination of both mechanical and electronic shifts in cone beam SPECT
    • Li J., Jaszczak R.J., Wang H., Greer K.L., and Coleman R.E. Determination of both mechanical and electronic shifts in cone beam SPECT. Phys Med Bio 39 (1993) 743-754
    • (1993) Phys Med Bio , vol.39 , pp. 743-754
    • Li, J.1    Jaszczak, R.J.2    Wang, H.3    Greer, K.L.4    Coleman, R.E.5
  • 4
    • 0028697033 scopus 로고
    • Geometric calibration method for multiple-head cone-beam SPECT system
    • Rizo Ph., Grangeat P., and Guillemaud R. Geometric calibration method for multiple-head cone-beam SPECT system. IEEE Trans Nucl Sci 41 (1994) 2748-2757
    • (1994) IEEE Trans Nucl Sci , vol.41 , pp. 2748-2757
    • Rizo, Ph.1    Grangeat, P.2    Guillemaud, R.3
  • 5
    • 0001091515 scopus 로고    scopus 로고
    • Virtual alignment of X-ray cone-beam tomography system using two calibration aperture measurements
    • Bronnikov A.V. Virtual alignment of X-ray cone-beam tomography system using two calibration aperture measurements. Opt Eng 38 2 (1999) 381-386
    • (1999) Opt Eng , vol.38 , Issue.2 , pp. 381-386
    • Bronnikov, A.V.1
  • 7
    • 0034764479 scopus 로고    scopus 로고
    • Implementation of a cone-beam reconstruction algorithm for the single-circle source orbit with embedded misalignment correction using homogeneous coordinates
    • Karolczak M., Schaller S., Engelke K., Lutz A., Taybenreuther U., Wiesent K., and Kalender W. Implementation of a cone-beam reconstruction algorithm for the single-circle source orbit with embedded misalignment correction using homogeneous coordinates. Med Phys 28 10 (2001) 2050-2069
    • (2001) Med Phys , vol.28 , Issue.10 , pp. 2050-2069
    • Karolczak, M.1    Schaller, S.2    Engelke, K.3    Lutz, A.4    Taybenreuther, U.5    Wiesent, K.6    Kalender, W.7
  • 8
    • 0033781494 scopus 로고    scopus 로고
    • Analytic method based on identification of ellipse parameters for scanner calibration in cone-beam tomography
    • Noo F., Clackdoyle R., Mennessier C., White A., and Roney J. Analytic method based on identification of ellipse parameters for scanner calibration in cone-beam tomography. Phys Med Biol 45 (2000) 3489-3508
    • (2000) Phys Med Biol , vol.45 , pp. 3489-3508
    • Noo, F.1    Clackdoyle, R.2    Mennessier, C.3    White, A.4    Roney, J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.