메뉴 건너뛰기




Volumn 24, Issue 6, 2006, Pages 761-773

MR image reconstruction of sparsely sampled 3D k-space data by projection-onto-convex sets

Author keywords

MR image reconstruction; Projection onto convex sets; Sparsely sampled 3D k space data; Zero filling

Indexed keywords

ALGORITHM; ARTICLE; DATA ANALYSIS; IMAGE QUALITY; NUCLEAR MAGNETIC RESONANCE IMAGING; PERFORMANCE; PRIORITY JOURNAL; SIGNAL NOISE RATIO; THREE DIMENSIONAL IMAGING;

EID: 33745644963     PISSN: 0730725X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.mri.2005.12.028     Document Type: Article
Times cited : (15)

References (20)
  • 2
    • 2442595660 scopus 로고    scopus 로고
    • Coronary artery imaging using three-dimensional breath-hold steady-state free precession with two-dimensional iterative partial Fourier reconstruction
    • Singh R.K., Deshpande V.S., Haacke E.M., Shea S.M., Xu Y., McCarthy R.M., et al. Coronary artery imaging using three-dimensional breath-hold steady-state free precession with two-dimensional iterative partial Fourier reconstruction. J Magn Reson Imaging 19 (2004) 645-649
    • (2004) J Magn Reson Imaging , vol.19 , pp. 645-649
    • Singh, R.K.1    Deshpande, V.S.2    Haacke, E.M.3    Shea, S.M.4    Xu, Y.5    McCarthy, R.M.6
  • 3
    • 0032899484 scopus 로고    scopus 로고
    • The effects of k-space data undersampling and discontinuities in keyhole functional MRI
    • Xiong J., Fox P.T., and Gao J. The effects of k-space data undersampling and discontinuities in keyhole functional MRI. Magn Reson Imaging 17 (1999) 109-119
    • (1999) Magn Reson Imaging , vol.17 , pp. 109-119
    • Xiong, J.1    Fox, P.T.2    Gao, J.3
  • 6
    • 0031848729 scopus 로고    scopus 로고
    • Rapid 2D time-resolved variable k-space sampling MR technique for passive catheter tracking during endovascular procedures
    • Unal O., Korosec F.R., Frayne R., Strother C.M., and Mistretta C.A. Rapid 2D time-resolved variable k-space sampling MR technique for passive catheter tracking during endovascular procedures. Magn Reson Med 40 (1998) 356-362
    • (1998) Magn Reson Med , vol.40 , pp. 356-362
    • Unal, O.1    Korosec, F.R.2    Frayne, R.3    Strother, C.M.4    Mistretta, C.A.5
  • 7
    • 0036158390 scopus 로고    scopus 로고
    • Continuously moving table data acquisition method for long FOV contrast-enhanced MRA and whole-body MRI
    • Kruger D.G., Riederer S.J., Grimm R.C., and Rossman P.J. Continuously moving table data acquisition method for long FOV contrast-enhanced MRA and whole-body MRI. Magn Reson Med 47 (2002) 224-231
    • (2002) Magn Reson Med , vol.47 , pp. 224-231
    • Kruger, D.G.1    Riederer, S.J.2    Grimm, R.C.3    Rossman, P.J.4
  • 8
    • 0141849137 scopus 로고    scopus 로고
    • Space-time relationship in continuously moving table method for large FOV peripheral contrast-enhanced magnetic resonance angiography
    • Sabati M., Lauzon M.L., and Frayne R. Space-time relationship in continuously moving table method for large FOV peripheral contrast-enhanced magnetic resonance angiography. Phys Med Biol 48 (2003) 2739-2752
    • (2003) Phys Med Biol , vol.48 , pp. 2739-2752
    • Sabati, M.1    Lauzon, M.L.2    Frayne, R.3
  • 10
    • 0023037011 scopus 로고
    • Halving MR imaging time by conjugation: demonstration at 3.5 kG
    • Feinberg D.A., Hale J.D., Watts J.C., Kaufman L., and Mark A. Halving MR imaging time by conjugation: demonstration at 3.5 kG. Radiology 161 (1986) 527-531
    • (1986) Radiology , vol.161 , pp. 527-531
    • Feinberg, D.A.1    Hale, J.D.2    Watts, J.C.3    Kaufman, L.4    Mark, A.5
  • 11
    • 0025324799 scopus 로고
    • Improved contrast at 1.5 Tesla using half-Fourier imaging: application to spin-echo and angiographic imaging
    • Haacke E.M., Mitchell J., and Lee D. Improved contrast at 1.5 Tesla using half-Fourier imaging: application to spin-echo and angiographic imaging. Magn Reson Imaging 8 (1990) 79-90
    • (1990) Magn Reson Imaging , vol.8 , pp. 79-90
    • Haacke, E.M.1    Mitchell, J.2    Lee, D.3
  • 12
    • 0034861763 scopus 로고    scopus 로고
    • Effect of windowing and zero-filled reconstruction of MRI data on spatial resolution and acquisition strategy
    • Bernstein M.A., Fain S.B., and Riederer S.J. Effect of windowing and zero-filled reconstruction of MRI data on spatial resolution and acquisition strategy. J Magn Reson Imaging 14 (2001) 270-280
    • (2001) J Magn Reson Imaging , vol.14 , pp. 270-280
    • Bernstein, M.A.1    Fain, S.B.2    Riederer, S.J.3
  • 14
    • 0001031295 scopus 로고
    • A fast, iterative partial Fourier technique capable of local phase recovery
    • Haacke E.M., Lindskog E.D., and Lin W. A fast, iterative partial Fourier technique capable of local phase recovery. J Magn Reson 92 (1991) 126-145
    • (1991) J Magn Reson , vol.92 , pp. 126-145
    • Haacke, E.M.1    Lindskog, E.D.2    Lin, W.3
  • 16
    • 19544382334 scopus 로고    scopus 로고
    • Partial Fourier partially parallel imaging
    • Bydder M., and Robson M.D. Partial Fourier partially parallel imaging. Magn Reson Med 53 (2005) 1393-1401
    • (2005) Magn Reson Med , vol.53 , pp. 1393-1401
    • Bydder, M.1    Robson, M.D.2
  • 17
    • 0034753024 scopus 로고    scopus 로고
    • Partial Fourier imaging in multi-dimensions: a means to save a full factor of two in time
    • Xu Y., and Haacke E.M. Partial Fourier imaging in multi-dimensions: a means to save a full factor of two in time. J Magn Reson Imaging 14 (2001) 628-635
    • (2001) J Magn Reson Imaging , vol.14 , pp. 628-635
    • Xu, Y.1    Haacke, E.M.2
  • 19
    • 0021948756 scopus 로고
    • Measurement of signal intensities in the presence of noise in MR images
    • Henkelman R.M. Measurement of signal intensities in the presence of noise in MR images. Med Phys 12 (1985) 232-233
    • (1985) Med Phys , vol.12 , pp. 232-233
    • Henkelman, R.M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.