메뉴 건너뛰기




Volumn 14, Issue 4, 2006, Pages 602-612

Fluidic operational amplifier for mock circulatory systems

Author keywords

Feedback controlled gear pump; Fluidic operational amplifier; Impedance; Mock circulatory systems

Indexed keywords

COMPUTER AIDED DESIGN; FEEDBACK CONTROL; GAIN CONTROL; GEAR PUMPS; OPERATIONAL AMPLIFIERS;

EID: 33745635044     PISSN: 10636536     EISSN: None     Source Type: Journal    
DOI: 10.1109/TCST.2006.876624     Document Type: Article
Times cited : (16)

References (20)
  • 1
    • 0031937479 scopus 로고    scopus 로고
    • "A computer controlled mock circulatory system for mono and biventricular assist device testing"
    • Jan
    • G. Ferrari, C. De Lazzri, R. Mimmo, G. Tosti, D. Ambrosi, and K. Gorczynska, "A computer controlled mock circulatory system for mono and biventricular assist device testing," Int. J. Artif. Organs, vol. 21, no. 1, pp. 26-36, Jan. 1998.
    • (1998) Int. J. Artif. Organs , vol.21 , Issue.1 , pp. 26-36
    • Ferrari, G.1    De Lazzri, C.2    Mimmo, R.3    Tosti, G.4    Ambrosi, D.5    Gorczynska, K.6
  • 2
    • 0027933590 scopus 로고
    • "Mock circulatory system for in vitro reproduction of the left ventricle, the arterial tree and their interaction with a left ventricular assist device"
    • G. Ferrari, C. De Lazzri, R. Mimmo, G. Tosti, D. Ambrosi, and K. Gorczynska, "Mock circulatory system for in vitro reproduction of the left ventricle, the arterial tree and their interaction with a left ventricular assist device," J. Med. Eng. Technol., vol. 18, pp. 87-95, 1994.
    • (1994) J. Med. Eng. Technol. , vol.18 , pp. 87-95
    • Ferrari, G.1    De Lazzri, C.2    Mimmo, R.3    Tosti, G.4    Ambrosi, D.5    Gorczynska, K.6
  • 3
    • 0028364289 scopus 로고
    • "A new mock circulatory loop and its application to the study of chemical additive and aortic pressure effects on hemolysis in the Penn State electric ventricular assist device"
    • L. A. Garrison, A. Frangos, D. B. Geselowitz, T. C. Lamson, and J. M. Tarbell, "A new mock circulatory loop and its application to the study of chemical additive and aortic pressure effects on hemolysis in the Penn State electric ventricular assist device," Artif. Organs, vol. 18, no. 5, pp. 397-407, 1994.
    • (1994) Artif. Organs , vol.18 , Issue.5 , pp. 397-407
    • Garrison, L.A.1    Frangos, A.2    Geselowitz, D.B.3    Lamson, T.C.4    Tarbell, J.M.5
  • 5
    • 0019799237 scopus 로고
    • "Design and evaluation of the pennsylvania state university mock circulatory system"
    • Jan
    • G. Rosenberg, W. M. Phillips, D. L. Landis, and W. S. Pierce, "Design and evaluation of the pennsylvania state university mock circulatory system," ASAIO J., vol. 4, no. 1, pp. 41-49, Jan. 1981.
    • (1981) ASAIO J. , vol.4 , Issue.1 , pp. 41-49
    • Rosenberg, G.1    Phillips, W.M.2    Landis, D.L.3    Pierce, W.S.4
  • 7
    • 0014603593 scopus 로고
    • "Time course of left ventricular pressure-volume relationship under various end-diastolic volumes"
    • H. Suga, "Time course of left ventricular pressure-volume relationship under various end-diastolic volumes," Jpn. Heart J., vol. 10, no. 6, pp. 509-515, 1969.
    • (1969) Jpn. Heart J. , vol.10 , Issue.6 , pp. 509-515
    • Suga, H.1
  • 8
    • 0020173090 scopus 로고
    • "Impedance loading servo pump system for excised canine ventricle"
    • K. Sunagawa, D. Burkhoff, D. Lim, and K. Sagawa, "Impedance loading servo pump system for excised canine ventricle," Amer. J. Phys., vol. 243, no. 2, pp. H346-H350, 1982.
    • (1982) Amer. J. Phys. , vol.243 , Issue.2
    • Sunagawa, K.1    Burkhoff, D.2    Lim, D.3    Sagawa, K.4
  • 10
    • 8744230601 scopus 로고    scopus 로고
    • "Feedback control design of an elastance-based mock circulatory system for heart assist device controller development"
    • Y.-C. Y
    • M. Loh and Y.-C. Y, "Feedback control design of an elastance-based mock circulatory system for heart assist device controller development," in Proc. Amer. Contr. Conf., 2004, pp. 1639-1644.
    • (2004) Proc. Amer. Contr. Conf. , pp. 1639-1644
    • Loh, M.1
  • 11
    • 0034744380 scopus 로고    scopus 로고
    • "Elastance-based control of a mock circulatory system"
    • L. A. Baloa, J. R. Boston, and J. F. Antaki, "Elastance-based control of a mock circulatory system," Ann. Biomed. Eng., vol. 29, no. 4, pp. 244-251, 2001.
    • (2001) Ann. Biomed. Eng. , vol.29 , Issue.4 , pp. 244-251
    • Baloa, L.A.1    Boston, J.R.2    Antaki, J.F.3
  • 14
    • 4243594553 scopus 로고    scopus 로고
    • "Modeling and control of left ventricular assist system"
    • Ph.D. thesis, Dept. Elect. Eng., Univ. Pittsburgh
    • S. Choi, "Modeling and control of left ventricular assist system," Ph.D. thesis, Dept. Elect. Eng., Univ. Pittsburgh, 1998.
    • (1998)
    • Choi, S.1
  • 16
    • 33745601609 scopus 로고
    • Massachuchettes Inst. Technol. [Online]
    • Massachuchettes Inst. Technol. (1994) Integrated Modeling of Physical Systems Dynamics. [Online] http://ocw.mit.edu/NR/rdonlyres/ Mechanical-Engineering/2-141Fall-2002/ 9034FDE4-40B5-49E5-9247-AFF7D310C744/0/gear_pump.pdf
    • (1994) Integrated Modeling of Physical Systems Dynamics
  • 17
    • 0141987780 scopus 로고    scopus 로고
    • "The theorectical flow ripple of an external gear pump"
    • N. D. Manring and S. B. Kasaragadda, "The theorectical flow ripple of an external gear pump," J. Dyn. Syst. Contr., vol. 125, no. 3, pp. 396-404, 2003.
    • (2003) J. Dyn. Syst. Contr. , vol.125 , Issue.3 , pp. 396-404
    • Manring, N.D.1    Kasaragadda, S.B.2
  • 20
    • 0013782124 scopus 로고
    • "Pressure-flow relationships in the ascending aorta and femoral artery of man"
    • D. J. Patel, J. C. Greenfield, W. G. Austen, A. G. Morrow, and D. L. Fry, "Pressure-flow relationships in the ascending aorta and femoral artery of man," J. Appl. Phys., vol. 20, no. 3, pp. 459-463, 1965.
    • (1965) J. Appl. Phys. , vol.20 , Issue.3 , pp. 459-463
    • Patel, D.J.1    Greenfield, J.C.2    Austen, W.G.3    Morrow, A.G.4    Fry, D.L.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.