-
1
-
-
0037454307
-
Photonic crystal carbohydrate sensors: Low ionic strength sugar sensing
-
Asher, S.A., Alexeev, V.L., Goponenko, A.V., Sharma, C.A., Lednev, I.K., Wilcox, C.S., and Finegold, D.N. 2003. Photonic crystal carbohydrate sensors: Low ionic strength sugar sensing. J. Am. Chem. Soc., 125: 3322-3329.
-
(2003)
J. Am. Chem. Soc.
, vol.125
, pp. 3322-3329
-
-
Asher, S.A.1
Alexeev, V.L.2
Goponenko, A.V.3
Sharma, C.A.4
Lednev, I.K.5
Wilcox, C.S.6
Finegold, D.N.7
-
2
-
-
0029388049
-
Metal island coated swelling polymer over mirror system (MICSPOMS): A new principle for measuring ionic strength
-
Aussenegg, F.R., Brunner, H., Leitner, A., Lobmaier, Ch., Schalkhammer, Th., and Pittner, F. 1995. Metal island coated swelling polymer over mirror system (MICSPOMS): a new principle for measuring ionic strength. Sensors and Actuators, B29: 204-209.
-
(1995)
Sensors and Actuators
, vol.B29
, pp. 204-209
-
-
Aussenegg, F.R.1
Brunner, H.2
Leitner, A.3
Lobmaier, Ch.4
Schalkhammer, Th.5
Pittner, F.6
-
3
-
-
0000257019
-
A fiber optical sensor for water in organic solvents based on polymer swelling
-
Bai, M. and Seitz, W.R. 1994. A fiber optical sensor for water in organic solvents based on polymer swelling. Talanta, 41 (6): 993-999.
-
(1994)
Talanta
, vol.41
, Issue.6
, pp. 993-999
-
-
Bai, M.1
Seitz, W.R.2
-
4
-
-
4544310764
-
Capacitive-type chemical sensors using thin silicon/polymer bimorph membranes
-
Chatzandroulis, S., Tegou, E., Goustouridis, D., Polymenakos, S., and Tsoukalas, D. 2004. Capacitive-type chemical sensors using thin silicon/polymer bimorph membranes. Sensors and Actuators, B103: 392-396.
-
(2004)
Sensors and Actuators
, vol.B103
, pp. 392-396
-
-
Chatzandroulis, S.1
Tegou, E.2
Goustouridis, D.3
Polymenakos, S.4
Tsoukalas, D.5
-
5
-
-
21844445569
-
Biomedical applications of micro- and nanoengineering II
-
Cole, M., Voelcker, N.H., and Thissen, H.W. 2005. Proceedings of SPIE-International Society for Engineering, 5651, (Biomedical applications of micro- and nanoengineering II), 19-27.
-
(2005)
Proceedings of SPIE-International Society for Engineering
, vol.5651
, pp. 19-27
-
-
Cole, M.1
Voelcker, N.H.2
Thissen, H.W.3
-
6
-
-
0037146920
-
Fiber optic Bragg grating sensor based on hydrogels for measuring salinity
-
Cong, J., Zhang, X., Chen, K., and Xu, J. 2002. Fiber optic Bragg grating sensor based on hydrogels for measuring salinity. Sensors and Actuators, B87: 487-490.
-
(2002)
Sensors and Actuators
, vol.B87
, pp. 487-490
-
-
Cong, J.1
Zhang, X.2
Chen, K.3
Xu, J.4
-
7
-
-
84888095351
-
Intelligent gels
-
Dagani, R. 1997. Intelligent gels. Chem. Eng. News, 75: 26-28.
-
(1997)
Chem. Eng. News
, vol.75
, pp. 26-28
-
-
Dagani, R.1
-
8
-
-
0025294059
-
Synthesis and application of thermally-reversible heterogels for drug delivery
-
Dong, L.C. and Hoffman, S. 1990. Synthesis and application of thermally-reversible heterogels for drug delivery. J. Controlled Release, 13: 21-30.
-
(1990)
J. Controlled Release
, vol.13
, pp. 21-30
-
-
Dong, L.C.1
Hoffman, S.2
-
11
-
-
41349103619
-
Structural modifications in the swelling of inhomogeneous microgels by light and neutron scattering
-
Fernandez-Barbero, A., Fernandez-Nieves, Grillo, I., and Lopez-Cabarcos, E. 2002. Structural modifications in the swelling of inhomogeneous microgels by light and neutron scattering. Phys. Review E, 66: 051803-1-051803-10.
-
(2002)
Phys. Review E
, vol.66
-
-
Fernandez-Barbero, A.1
Fernandez-Nieves2
Grillo, I.3
Lopez-Cabarcos, E.4
-
13
-
-
33645687846
-
Statistical mechanics of cross-linked polymer networks. II. Swelling
-
Flory, P.J. and Rehner, J. 1943. Statistical mechanics of cross-linked polymer networks. II. Swelling. J. Chem. Physics, 11: 521-546.
-
(1943)
J. Chem. Physics
, vol.11
, pp. 521-546
-
-
Flory, P.J.1
Rehner, J.2
-
15
-
-
0032590349
-
A magnetostatic-coupling based remote query sensor for environmental monitoring
-
Grimes, C.A., Stoyanov, P.G., Liu, Y., Tong, C., Ong, K.G., Loiselle, K., Shaw, M., Doherty, S.A., and Seitz, W.R. 1999. A magnetostatic-coupling based remote query sensor for environmental monitoring. J. Phys. D: Appl. Phys., 32: 1329-1335.
-
(1999)
J. Phys. D: Appl. Phys.
, vol.32
, pp. 1329-1335
-
-
Grimes, C.A.1
Stoyanov, P.G.2
Liu, Y.3
Tong, C.4
Ong, K.G.5
Loiselle, K.6
Shaw, M.7
Doherty, S.A.8
Seitz, W.R.9
-
16
-
-
10844287830
-
In situ device for salinity measurements (chloride detection) of ocean surface
-
Grossman, B., Yongphiphatwong, T., and Sokol, M. 2005. In situ device for salinity measurements (chloride detection) of ocean surface. Optics and Laser Technology, 37: 217-223.
-
(2005)
Optics and Laser Technology
, vol.37
, pp. 217-223
-
-
Grossman, B.1
Yongphiphatwong, T.2
Sokol, M.3
-
17
-
-
0031259910
-
Polymerized colloidal crystal hydrogel films as intelligent chemical sensing materials
-
Holtz, J.H. and Asher, S.A. 1997. Polymerized colloidal crystal hydrogel films as intelligent chemical sensing materials. Nature, 389: 829-832.
-
(1997)
Nature
, vol.389
, pp. 829-832
-
-
Holtz, J.H.1
Asher, S.A.2
-
18
-
-
0032003968
-
Intelligent polymerized crystalline colloidal arrays: Novel chemical sensor materials
-
Holtz, J.H., Holtz, J.S.W., Munro, C.H., and Asher, S.A. 1998. Intelligent polymerized crystalline colloidal arrays: novel chemical sensor materials. Anal. Chem., 70: 780-791.
-
(1998)
Anal. Chem.
, vol.70
, pp. 780-791
-
-
Holtz, J.H.1
Holtz, J.S.W.2
Munro, C.H.3
Asher, S.A.4
-
19
-
-
0033712558
-
Integrated chemiresistor array for small sensor platforms
-
Part 1. detection and remediation technologies for mines and minelike targets V
-
Hughes, R.C., Casalnuovo, S.A., Wessendork, K.O., Savignon, D.J., Hietala, L.S., Patel, S.V., and Heller, E.J. 2000. Integrated chemiresistor array for small sensor platforms, Proceedings of SPIE (Part 1. detection and remediation technologies for mines and minelike targets V), 4038: 519-529.
-
(2000)
Proceedings of SPIE
, vol.4038
, pp. 519-529
-
-
Hughes, R.C.1
Casalnuovo, S.A.2
Wessendork, K.O.3
Savignon, D.J.4
Hietala, L.S.5
Patel, S.V.6
Heller, E.J.7
-
20
-
-
0032501420
-
Totally synthetic polymer gels responding to external glucose concentration: Their preparation and application to On-Off regulation of insulin release
-
Katanoka, K., Miyazaki, H., Bunya, M., Okano, T., and Sakurai, Y. 1998. Totally synthetic polymer gels responding to external glucose concentration: their preparation and application to On-Off regulation of insulin release. J. Am. Chem. Soc., 120: 12694-12695.
-
(1998)
J. Am. Chem. Soc.
, vol.120
, pp. 12694-12695
-
-
Katanoka, K.1
Miyazaki, H.2
Bunya, M.3
Okano, T.4
Sakurai, Y.5
-
21
-
-
33745620865
-
Swellable molecularly imprinted poly N-(N-propyl)acrylamide particles for detection of emerging organic contaminants using surface plasmon resonance spectroscopy
-
submitted
-
Lavine, B.K., Westover, D.J., Kaval, N., Mirjankar, N., Oxenford, L., and Mwangi, G.K. 2006. Swellable molecularly imprinted poly N-(N-propyl)acrylamide particles for detection of emerging organic contaminants using surface plasmon resonance spectroscopy. Anal. Chem. submitted.
-
(2006)
Anal. Chem.
-
-
Lavine, B.K.1
Westover, D.J.2
Kaval, N.3
Mirjankar, N.4
Oxenford, L.5
Mwangi, G.K.6
-
22
-
-
0034605443
-
Photonic crystal chemical sensors: PH and ionic strength
-
Lee, K. and Asher, A.S. 2000. Photonic crystal chemical sensors: pH and ionic strength. J. Am. Chem. Soc., 122: 9534-9537.
-
(2000)
J. Am. Chem. Soc.
, vol.122
, pp. 9534-9537
-
-
Lee, K.1
Asher, A.S.2
-
23
-
-
0030291735
-
Adhesion of polymer films to oxidized silicon and its effect on performance of a conductometric pH sensor
-
Lesho, M.J. and Sheppard, N.F. 1996. Adhesion of polymer films to oxidized silicon and its effect on performance of a conductometric pH sensor. Sensors and Actuators, B37: 61.
-
(1996)
Sensors and Actuators
, vol.B37
, pp. 61
-
-
Lesho, M.J.1
Sheppard, N.F.2
-
24
-
-
0242410909
-
Demonstration of etched cladding fiber Bragg grating-based sensors with hydrogel coating
-
Liu, X., Zhang, X., Cong, J., Xu, J., and Chen, K. 2003. Demonstration of etched cladding fiber Bragg grating-based sensors with hydrogel coating. Sensors and Actuators, B96: 468-472.
-
(2003)
Sensors and Actuators
, vol.B96
, pp. 468-472
-
-
Liu, X.1
Zhang, X.2
Cong, J.3
Xu, J.4
Chen, K.5
-
25
-
-
17544389945
-
Coherent optical frequency domain reflectometry for interrogation of bend-based fiber optic hydrocarbon sensors
-
Lopez, R.M., Spirin, V.V., Shlyagin, M.G., Miridonov, S.V., Beltran, G., Kuzin, E.A., and Marquez Lucero, A. 2004. Coherent optical frequency domain reflectometry for interrogation of bend-based fiber optic hydrocarbon sensors. Optical Fiber Technology, 10: 79-90.
-
(2004)
Optical Fiber Technology
, vol.10
, pp. 79-90
-
-
Lopez, R.M.1
Spirin, V.V.2
Shlyagin, M.G.3
Miridonov, S.V.4
Beltran, G.5
Kuzin, E.A.6
Marquez Lucero, A.7
-
26
-
-
0028113153
-
An optical biosensor using a fluorescent, swelling sensing element
-
McCurley, M.F. 1994. An optical biosensor using a fluorescent, swelling sensing element. Biosensors & Bioelectronics, 9: 527-533.
-
(1994)
Biosensors & Bioelectronics
, vol.9
, pp. 527-533
-
-
McCurley, M.F.1
-
27
-
-
0025822985
-
Fiber-optic sensor for Salt concentration based on polymer swelling coupled to optical displacement
-
McCurley, M.F. and Seitz, W.R. 1991. Fiber-optic sensor for Salt concentration based on polymer swelling coupled to optical displacement. Anal. Chim. Acta, 249: 373-380.
-
(1991)
Anal. Chim. Acta
, vol.249
, pp. 373-380
-
-
McCurley, M.F.1
Seitz, W.R.2
-
28
-
-
33745632454
-
Swelling of a polymer membrane for use in a glucose biosensor
-
McCurley, M.F. and Seitz, W.R. 1992. Swelling of a polymer membrane for use in a glucose biosensor. In ACS Symposium Series, 487: 301-309.
-
(1992)
ACS Symposium Series
, vol.487
, pp. 301-309
-
-
McCurley, M.F.1
Seitz, W.R.2
-
29
-
-
0037123725
-
New mode of drug delivery: Long term autonomous rhythmic hormone release across a hydrogel membrane
-
Misra, G. and Siegel, R.J. 2002. New mode of drug delivery: long term autonomous rhythmic hormone release across a hydrogel membrane. J. Controlled Release, 81: 1-6.
-
(2002)
J. Controlled Release
, vol.81
, pp. 1-6
-
-
Misra, G.1
Siegel, R.J.2
-
31
-
-
0025208565
-
Chemically actuated electronic switch
-
Neuburger, G. and Warren, P.C. 1990. Chemically actuated electronic switch. Sensors and Actuators, B1: 326-332.
-
(1990)
Sensors and Actuators
, vol.B1
, pp. 326-332
-
-
Neuburger, G.1
Warren, P.C.2
-
32
-
-
0031172661
-
Characterization of protein release through glucose-sensitive hydrogel membranes
-
Obaidat, A.A. and Park, K. 1997. Characterization of protein release through glucose-sensitive hydrogel membranes. Biomaterials, 18: 801-806.
-
(1997)
Biomaterials
, vol.18
, pp. 801-806
-
-
Obaidat, A.A.1
Park, K.2
-
33
-
-
0033622088
-
Temperature-sensitive aqueous microgels
-
Pelton, R. 2000. Temperature-sensitive aqueous microgels. Adv. Colloid. Interface Sci., 85: 1-33.
-
(2000)
Adv. Colloid. Interface Sci.
, vol.85
, pp. 1-33
-
-
Pelton, R.1
-
34
-
-
19044370271
-
Polymer networks as actuator and sensor systems to be used for automation of biomedical devices
-
Richter, A., Krause, W., Lieng, J., and Arndt, K.F. 2005. Polymer networks as actuator and sensor systems to be used for automation of biomedical devices. Biomed. Tech., 50 (3): 66-68.
-
(2005)
Biomed. Tech.
, vol.50
, Issue.3
, pp. 66-68
-
-
Richter, A.1
Krause, W.2
Lieng, J.3
Arndt, K.F.4
-
36
-
-
0000748921
-
An optically sensitive membrane for pH based on swellable polymer microspheres in a hydrogel
-
Rooney, M.T.V. and Seitz, W.R. 1999. An optically sensitive membrane for pH based on swellable polymer microspheres in a hydrogel. Anal. Comm., 36: 267-270.
-
(1999)
Anal. Comm.
, vol.36
, pp. 267-270
-
-
Rooney, M.T.V.1
Seitz, W.R.2
-
37
-
-
0029292576
-
Humidity sensor durable at high humidity using simultaneously crosslinked and quaternized poly(chloromethyl styrene)
-
Sakai, Y., Sadaoka, H., Matsuguchi, M., and Sakai, H. 1995. Humidity sensor durable at high humidity using simultaneously crosslinked and quaternized poly(chloromethyl styrene). Sensors and Actuators, B24-25: 689-691.
-
(1995)
Sensors and Actuators
, vol.B24-25
, pp. 689-691
-
-
Sakai, Y.1
Sadaoka, H.2
Matsuguchi, M.3
Sakai, H.4
-
38
-
-
0001913281
-
Osmotic de-swelling of polystyrene microgel particles
-
Saunders, B.R. and Vincent, B. 1997. Osmotic de-swelling of polystyrene microgel particles. Colloid Polym. Sci., 275: 9-17.
-
(1997)
Colloid Polym. Sci.
, vol.275
, pp. 9-17
-
-
Saunders, B.R.1
Vincent, B.2
-
39
-
-
0004869855
-
New directions in fiber optic chemical sensors: Sensors based on polymer swelling
-
Seitz, W.R. 1993. New directions in fiber optic chemical sensors: sensors based on polymer swelling. J. Mol. Structure, 292: 105-114.
-
(1993)
J. Mol. Structure
, vol.292
, pp. 105-114
-
-
Seitz, W.R.1
-
40
-
-
0032721878
-
Derivatized, swellable polymer microspheres for chemical transduction
-
Seitz, W.R., Rooney, M.T.V., Miele, E.W., Wang, H., Kaval, N., Zhang, L., Doherty, S., Milde, S., and Lenda, J. 1999. Derivatized, swellable polymer microspheres for chemical transduction. Anal. Chim. Acta., 400: 55-64.
-
(1999)
Anal. Chim. Acta.
, vol.400
, pp. 55-64
-
-
Seitz, W.R.1
Rooney, M.T.V.2
Miele, E.W.3
Wang, H.4
Kaval, N.5
Zhang, L.6
Doherty, S.7
Milde, S.8
Lenda, J.9
-
41
-
-
17044440646
-
An Optical Chemical Sensor Based on Swellable Dicarboxylate functionalized polymer microspheres for pH copper and calcium determination
-
Shakhser, Z., Odeh, I., Jabr, S., and Seitz, W.R. 2004. An Optical Chemical Sensor Based on Swellable Dicarboxylate functionalized polymer microspheres for pH copper and calcium determination. Microchim. Acta., 144: 147-153.
-
(2004)
Microchim. Acta.
, vol.144
, pp. 147-153
-
-
Shakhser, Z.1
Odeh, I.2
Jabr, S.3
Seitz, W.R.4
-
42
-
-
0028773527
-
Single fiber-optic pH sensor based on changes in reflection accompanying polymer swelling
-
Shakhsher, Z. and Seitz, W.R. 1994. Single fiber-optic pH sensor based on changes in reflection accompanying polymer swelling. Anal. Chem., 66: 1731-1735.
-
(1994)
Anal. Chem.
, vol.66
, pp. 1731-1735
-
-
Shakhsher, Z.1
Seitz, W.R.2
-
43
-
-
0029350624
-
Microfabricated conductimetric pH sensor
-
Sheppard, N.F., Lesho, M.J., McNally, P., and Francomacaro, S. 1995. Microfabricated conductimetric pH sensor. Sensors and Actuators, B28: 95-102.
-
(1995)
Sensors and Actuators
, vol.B28
, pp. 95-102
-
-
Sheppard, N.F.1
Lesho, M.J.2
McNally, P.3
Francomacaro, S.4
-
44
-
-
0027168201
-
Design of a conductimetric pH microsensor based on reversibly swelling hydrogels
-
Sheppard, N.F., Tucker, R.C., and Salehi-Had, S. 1993. Design of a conductimetric pH microsensor based on reversibly swelling hydrogels. Sensors and Actuators, B10: 73-x.
-
(1993)
Sensors and Actuators
, vol.B10
-
-
Sheppard, N.F.1
Tucker, R.C.2
Salehi-Had, S.3
-
45
-
-
4644259580
-
Novel swelling/shrinking behaviors of glucose-binding hydrogels and their potential use in a microfluidic insulin delivery system
-
Siegel, R.A., Gu, Y., Baldi, A., and Ziare, B. 2004. Novel swelling/shrinking behaviors of glucose-binding hydrogels and their potential use in a microfluidic insulin delivery system. Macromol. Symp., 207: 249-256.
-
(2004)
Macromol. Symp.
, vol.207
, pp. 249-256
-
-
Siegel, R.A.1
Gu, Y.2
Baldi, A.3
Ziare, B.4
-
46
-
-
0032105814
-
A remotely interrogatable sensor for chemical monitoring
-
Stoyanov, P.G., Doherty, S.A., Grimes, C.A., and Seitz, W.R. 1998. A remotely interrogatable sensor for chemical monitoring. IEEE Transactions on Magnetics, 34 (4): 1315-1317.
-
(1998)
IEEE Transactions on Magnetics
, vol.34
, Issue.4
, pp. 1315-1317
-
-
Stoyanov, P.G.1
Doherty, S.A.2
Grimes, C.A.3
Seitz, W.R.4
-
47
-
-
0028885611
-
The delivery of insulin from aqueous and non-aqueous reservoirs governed by a glucose sensitive gel membrane
-
Taylor, M.J., Tanna, S., Taylor, P.M., and Adams, G. 1995. The delivery of insulin from aqueous and non-aqueous reservoirs governed by a glucose sensitive gel membrane. J. Drug Targeting, 3: 209-216.
-
(1995)
J. Drug Targeting
, vol.3
, pp. 209-216
-
-
Taylor, M.J.1
Tanna, S.2
Taylor, P.M.3
Adams, G.4
-
48
-
-
5844242724
-
A mass spectrometric investigation of the water-soluble oligomers remaining after the emulsion polymerization of methyl methacrylate
-
Thomson, B., Rudin, A., and Lajoie, G. 1995. A mass spectrometric investigation of the water-soluble oligomers remaining after the emulsion polymerization of methyl methacrylate. J. Poly. Sci. Pt. A, 33: 345-357.
-
(1995)
J. Poly. Sci. Pt. A
, vol.33
, pp. 345-357
-
-
Thomson, B.1
Rudin, A.2
Lajoie, G.3
-
50
-
-
0033353905
-
pH sensor based on swellable poly(3-nitro-4-hydroxystyrene) microspheres in a hydrogel
-
Internal Standardization and Calibration Architecture for Chemical Sensors, Boston, MA
-
Wang, H. and Seitz, W.R. 1999. pH sensor based on swellable poly(3-nitro-4-hydroxystyrene) microspheres in a hydrogel, Proceedings of SPIE, 3856 (Internal Standardization and Calibration Architecture for Chemical Sensors, Boston, MA), 224-231.
-
(1999)
Proceedings of SPIE
, vol.3856
, pp. 224-231
-
-
Wang, H.1
Seitz, W.R.2
-
51
-
-
0037383683
-
Synthesis and evaluation of nitrated poly(4-hydroxy-Styrene) microspheres for pH sensing
-
Westover, D., Seitz, W.R., and Lavine, B.K. 2003. Synthesis and evaluation of nitrated poly(4-hydroxy-Styrene) microspheres for pH sensing. Microchem. J., 74: 121-129.
-
(2003)
Microchem. J.
, vol.74
, pp. 121-129
-
-
Westover, D.1
Seitz, W.R.2
Lavine, B.K.3
-
52
-
-
0022813956
-
Humidity sensors: Principles and applications
-
Yamazoe, N. and Shimizu, Y. 1986. Humidity sensors: principles and applications. Sensors and Actuators, 10: 379-398.
-
(1986)
Sensors and Actuators
, vol.10
, pp. 379-398
-
-
Yamazoe, N.1
Shimizu, Y.2
-
53
-
-
0030759705
-
A sensor for pH based on an optical reflective device coupled to the swelling of an aminated polystyrene membrane
-
Zhang, L., Langmuir, M.E., Bai, M., and Seitz, W.R. 1997. A sensor for pH based on an optical reflective device coupled to the swelling of an aminated polystyrene membrane. Talanta, 44: 1691-1698.
-
(1997)
Talanta
, vol.44
, pp. 1691-1698
-
-
Zhang, L.1
Langmuir, M.E.2
Bai, M.3
Seitz, W.R.4
-
54
-
-
0036042104
-
A pH sensor based on force generated by pH-dependent polymer swelling
-
Zhang, L. and Seitz, W.R. 2002. A pH sensor based on force generated by pH-dependent polymer swelling. Anal. Bioanal. Chem., 373: 555-559.
-
(2002)
Anal. Bioanal. Chem.
, vol.373
, pp. 555-559
-
-
Zhang, L.1
Seitz, W.R.2
-
55
-
-
0005318214
-
Aminated polystyrene membranes for a fiber optic pH sensor based on reflectance changes accompanying polymer swelling
-
Zhang, Z., Shakhser, Z., and Seitz, W.R. 1995. Aminated polystyrene membranes for a fiber optic pH sensor based on reflectance changes accompanying polymer swelling. Mikro. Acta, 121 (1-4): 41-50.
-
(1995)
Mikro. Acta
, vol.121
, Issue.1-4
, pp. 41-50
-
-
Zhang, Z.1
Shakhser, Z.2
Seitz, W.R.3
|