메뉴 건너뛰기




Volumn 44, Issue 1-2, 2006, Pages 54-60

Symmetric sensor for applanation resonance tomometry of the eye

Author keywords

Applanation; Eye; Glaucoma; Intraocular pressure; Resonance sensor; Tonometry

Indexed keywords

BIOLOGICAL ORGANS; IMAGE SENSORS; PRESSURE MEASUREMENT; PRESSURE TRANSDUCERS;

EID: 33745447866     PISSN: 01400118     EISSN: None     Source Type: Journal    
DOI: 10.1007/s11517-005-0005-1     Document Type: Article
Times cited : (11)

References (15)
  • 1
    • 0035182854 scopus 로고    scopus 로고
    • Clinical comparison of the measurement of the IOP with the ocular blood flow tonometer, the Tonopen XL and the Goldmann applanation tonometer
    • Bafa M, Lambrinakis I, Dayan M, Birch M (2001) Clinical comparison of the measurement of the IOP with the ocular blood flow tonometer, the Tonopen XL and the Goldmann applanation tonometer. Acta Ophthalmol Scand 79:15-18
    • (2001) Acta Ophthalmol Scand , vol.79 , pp. 15-18
    • Bafa, M.1    Lambrinakis, I.2    Dayan, M.3    Birch, M.4
  • 2
    • 0031703801 scopus 로고    scopus 로고
    • Tonometry in adults and children. A manometric evaluation of pneumatonometry, applanation, and TonoPen in vitro and in vivo
    • Eisenberg DL, Sherman BG, Mckeown CA, Schuman JS (1998) Tonometry in adults and children. A manometric evaluation of pneumatonometry, applanation, and TonoPen in vitro and in vivo. Ophthalmology 105:1173-1181
    • (1998) Ophthalmology , vol.105 , pp. 1173-1181
    • Eisenberg, D.L.1    Sherman, B.G.2    Mckeown, C.A.3    Schuman, J.S.4
  • 3
    • 33745434252 scopus 로고    scopus 로고
    • A resonator sensor for evaluation of prostate tissue composition and hardness
    • MBEC, Tallinn, Estonia
    • Eklund A, Bergh A, Lindahl OA (1999) A resonator sensor for evaluation of prostate tissue composition and hardness. In: 11th Nordic-Baltic conference on biomedical engineering, vol 37, MBEC, Tallinn, Estonia, pp 181-182
    • (1999) 11th Nordic-Baltic Conference on Biomedical Engineering , vol.37 , pp. 181-182
    • Eklund, A.1    Bergh, A.2    Lindahl, O.A.3
  • 4
    • 0033863370 scopus 로고    scopus 로고
    • A resonator sensor for measurement of intraocular pressure - Evaluation in an in vitro pig-eye model
    • Eklund A, Backlund T, Lindahl OA (2000) A resonator sensor for measurement of intraocular pressure - evaluation in an in vitro pig-eye model. Physiol Meas 21:355-367
    • (2000) Physiol Meas , vol.21 , pp. 355-367
    • Eklund, A.1    Backlund, T.2    Lindahl, O.A.3
  • 5
    • 0038576901 scopus 로고    scopus 로고
    • Applanation resonance sensor for measuring intraocular pressure - A continuos force and area measurement method
    • Eklund A, Hallberg P, Lindén C, Lindahl OA (2003) Applanation resonance sensor for measuring intraocular pressure - a continuos force and area measurement method. Invest Ophthalmol Vis Sci 44:3017-3024
    • (2003) Invest Ophthalmol Vis Sci , vol.44 , pp. 3017-3024
    • Eklund, A.1    Hallberg, P.2    Lindén, C.3    Lindahl, O.A.4
  • 6
    • 12444327237 scopus 로고    scopus 로고
    • Evaluation of applanation resonator sensors for intraocular pressure measurement, results from clinical and in vitro studies
    • Eklund A, Lindén C, Backlund T, Andersson B, Lindahl OA (2003) Evaluation of applanation resonator sensors for intraocular pressure measurement, results from clinical and in vitro studies. Med Biol Eng Comput 41:190-197
    • (2003) Med Biol Eng Comput , vol.41 , pp. 190-197
    • Eklund, A.1    Lindén, C.2    Backlund, T.3    Andersson, B.4    Lindahl, O.A.5
  • 7
    • 0002523438 scopus 로고
    • Applanation tonometry
    • Newell FW (ed) Jr. Foundation, Josiah Macy
    • Goldmann H (1957) Applanation tonometry. In: Newell FW (ed) Glaucoma. Transactions of the second conference. Jr. Foundation, Josiah Macy, pp 167-220
    • (1957) Glaucoma. Transactions of the Second Conference , pp. 167-220
    • Goldmann, H.1
  • 9
    • 33745448992 scopus 로고    scopus 로고
    • Comparison of Goldmann applanation and applanation resonance tonometry in a vertical in vitro porcine-eye model
    • (In press)
    • Hallberg P, Lindén C, Lindahl OA, Bäcklund T, Eklund A (2005) Comparison of Goldmann applanation and applanation resonance tonometry in a vertical in vitro porcine-eye model. J Med Eng Technol (In press)
    • (2005) J Med Eng Technol
    • Hallberg, P.1    Lindén, C.2    Lindahl, O.A.3    Bäcklund, T.4    Eklund, A.5
  • 10
    • 0036822851 scopus 로고    scopus 로고
    • Reduction of intraocular pressure and glaucoma progression: Results from the Early Manifest Glaucoma Trial
    • Heijl A, Leske MC, Bengtsson B, Hyman L, Hussein M (2002) Reduction of intraocular pressure and glaucoma progression: Results from the Early Manifest Glaucoma Trial. Arch Ophthalmol 120:1268-1279
    • (2002) Arch Ophthalmol , vol.120 , pp. 1268-1279
    • Heijl, A.1    Leske, M.C.2    Bengtsson, B.3    Hyman, L.4    Hussein, M.5
  • 11
    • 0034115306 scopus 로고    scopus 로고
    • A new induction-based impact method for measuring intraocular pressure
    • Kontiola AI (2000) A new induction-based impact method for measuring intraocular pressure. Acta Ophthalmol Scand 78:142-145
    • (2000) Acta Ophthalmol Scand , vol.78 , pp. 142-145
    • Kontiola, A.I.1
  • 12
    • 0026384273 scopus 로고
    • Development of new type tactile sensor for detecting hardness and/or softness of an object like the human hand
    • San Francisco
    • Omata S, Terunuma Y (1991) Development of new type tactile sensor for detecting hardness and/or softness of an object like the human hand. In: 6th international conference of solid-state sensors and actuators, San Francisco, pp 868-871
    • (1991) 6th International Conference of Solid-state Sensors and Actuators , pp. 868-871
    • Omata, S.1    Terunuma, Y.2
  • 13
    • 0010621101 scopus 로고
    • Zur Applanationtonometri an der spaltlampe
    • Schmidt T (1957) Zur Applanationtonometri an der spaltlampe. Ophthalmologica 133:337-342
    • (1957) Ophthalmologica , vol.133 , pp. 337-342
    • Schmidt, T.1
  • 14
    • 0024587287 scopus 로고
    • Intraocular pressure and glaucoma
    • Sommer A (1989) Intraocular pressure and glaucoma. Am J Ophthalmol 107:186-188
    • (1989) Am J Ophthalmol , vol.107 , pp. 186-188
    • Sommer, A.1
  • 15
    • 0027291601 scopus 로고
    • Sources of error with use of Goldmann-type tonometers
    • Whitacre MM, Stein R (1993) Sources of error with use of Goldmann-type tonometers. Surv Ophthalmol 38:1-30
    • (1993) Surv Ophthalmol , vol.38 , pp. 1-30
    • Whitacre, M.M.1    Stein, R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.