메뉴 건너뛰기




Volumn 6142 I, Issue , 2006, Pages

A multi-beam x-ray imaging system based on carbon nanotube field emitters

Author keywords

Carbon nanotube; Field emission; Multi beam x ray source; Tomosynthesis

Indexed keywords

ELECTRONIC SWITCHING; FIELD EMISSION; MULTI-BEAM FIELD EMISSION X-RAY (MBFEX); MULTI-BEAM X-RAY SOURCE; TOMOSYNTHESIS;

EID: 33745390090     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.654006     Document Type: Conference Paper
Times cited : (26)

References (19)
  • 1
    • 0015789441 scopus 로고
    • Reconstruction of densities from their projections with applications in radiological physics
    • A.M. Cormack, Reconstruction of densities from their projections with applications in radiological physics. Phys. Med. Biol, 1973.18: p. 195-207.
    • (1973) Phys. Med. Biol , vol.18 , pp. 195-207
    • Cormack, A.M.1
  • 2
    • 0015911128 scopus 로고
    • Computerized transverse axial scanning tomography:1. Description of system
    • G.N. Hounsfield, Computerized transverse axial scanning tomography:1. Description of system. Br J Radiol, 1973.46: p. 1016-1022.
    • (1973) Br J Radiol , vol.46 , pp. 1016-1022
    • Hounsfield, G.N.1
  • 4
    • 0017091496 scopus 로고
    • Principles of Computer Assisted Tomography (CAT) in Radiographic and Radioisotopic Imaging
    • R.A. Brooks and G. Di Chiro, Principles of Computer Assisted Tomography (CAT) in Radiographic and Radioisotopic Imaging. PHYS. MED. BIOL., 1976. 21(5): p. 689-732.
    • (1976) PHYS. MED. BIOL. , vol.21 , Issue.5 , pp. 689-732
    • Brooks, R.A.1    Di Chiro, G.2
  • 6
    • 0141928682 scopus 로고    scopus 로고
    • Digital x-ray tomosynthesis: Current state of the art and clinical potential
    • J.T. Dobbins III and D.J. Godfrey, Digital x-ray tomosynthesis: current state of the art and clinical potential. Phys. Med. Biol., 2003.48: p. R65-R106.
    • (2003) Phys. Med. Biol. , vol.48
    • Dobbins III, J.T.1    Godfrey, D.J.2
  • 7
    • 0036613732 scopus 로고    scopus 로고
    • Three-dimensional x-ray laminography as a tool for detection and characterization of BGA package defects
    • T.D. Moore, D. Vanderstraeten, and P.M. Forssell, Three-dimensional x-ray laminography as a tool for detection and characterization of BGA package defects. IEEE Trans on Components and packaging technologies, 2002. 25(2): p. 224.
    • (2002) IEEE Trans on Components and Packaging Technologies , vol.25 , Issue.2 , pp. 224
    • Moore, T.D.1    Vanderstraeten, D.2    Forssell, P.M.3
  • 11
    • 25844512685 scopus 로고    scopus 로고
    • A nanotube-based field emission x-ray source for micro-computed tomography
    • Submitted to
    • J. Zhang, et al., A nanotube-based field emission x-ray source for micro-computed tomography. Submitted to Review of Scientific Instruments, 2005.
    • (2005) Review of Scientific Instruments
    • Zhang, J.1
  • 12
    • 20844438487 scopus 로고    scopus 로고
    • Stationary scanning x-ray source based on carbon nanotube field emitters
    • J. Zhang, et al., Stationary scanning x-ray source based on carbon nanotube field emitters. Appl. Phys. Lett., 2005. 86: p. 184104.
    • (2005) Appl. Phys. Lett. , vol.86 , pp. 184104
    • Zhang, J.1
  • 13
    • 0035803384 scopus 로고    scopus 로고
    • Fabrication and electron field emission properties of carbon nanotube films by electrophoretic deposition
    • B. Gao, et al., Fabrication and electron field emission properties of carbon nanotube films by electrophoretic deposition. Adv. Mater., 2001.13(23): p. 1770-1774.
    • (2001) Adv. Mater. , vol.13 , Issue.23 , pp. 1770-1774
    • Gao, B.1
  • 14
    • 0026906003 scopus 로고
    • Potential of digital flashing tomosynthesis for angiocardiographic evaluation
    • G.M. Stiel, L.S. Stiel, and C.A. Nienaber, Potential of digital flashing tomosynthesis for angiocardiographic evaluation. J. Digit. Imaging, 1992. 5(3): p. 194-205.
    • (1992) J. Digit. Imaging , vol.5 , Issue.3 , pp. 194-205
    • Stiel, G.M.1    Stiel, L.S.2    Nienaber, C.A.3
  • 15
    • 0022347477 scopus 로고
    • First clinical results with digital flashing tomosynthesis in coronary angiography
    • P. Haaker, et al., First clinical results with digital flashing tomosynthesis in coronary angiography. Eur Heart J., 1985.6(11): p. 913-920.
    • (1985) Eur Heart J. , vol.6 , Issue.11 , pp. 913-920
    • Haaker, P.1
  • 16
    • 0021810571 scopus 로고
    • Coronary angiography with flashing tomosynthesis
    • H. Becher, et al., Coronary angiography with flashing tomosynthesis. Eur Heart J., 1985. 6(5): p. 399-408.
    • (1985) Eur Heart J. , vol.6 , Issue.5 , pp. 399-408
    • Becher, H.1
  • 17
    • 0019938528 scopus 로고
    • Work in progress. Flashing tomosynthesis: A tomographic technique for quantitative coronary angiography
    • H. Woelke, et al., Work in progress. Flashing tomosynthesis: a tomographic technique for quantitative coronary angiography. Radiology, 1982.145(2): p. 357-360.
    • (1982) Radiology , vol.145 , Issue.2 , pp. 357-360
    • Woelke, H.1
  • 18
    • 0018830267 scopus 로고
    • Flashing tomosynthesis - A new tomographic method
    • M. Nadjmi, et al., Flashing tomosynthesis - a new tomographic method. Neuroradiology, 1980. 19(3): p. 113-117.
    • (1980) Neuroradiology , vol.19 , Issue.3 , pp. 113-117
    • Nadjmi, M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.