메뉴 건너뛰기




Volumn 18, Issue 11, 1997, Pages 1071-1076

A novel method of scatter correction using a single isotope for simultaneous emission and transmission data

Author keywords

[No Author keywords available]

Indexed keywords

TECHNETIUM 99M;

EID: 0030859658     PISSN: 01433636     EISSN: 14735628     Source Type: Journal    
DOI: 10.1080/00006231-199711000-00011     Document Type: Article
Times cited : (7)

References (15)
  • 1
    • 0015153102 scopus 로고
    • Optimizing the window of an anger camera for 99mtc
    • Sanders TP, Sanders TD, Kuhl DE. Optimizing the window of an Anger camera for 99mTc. J Nucl Med 1971; 12: 703-706.
    • (1971) J Nucl Med , vol.12 , pp. 703-706
    • Sanders, T.P.1    Sanders, T.D.2    Kuhl, D.E.3
  • 2
    • 0015145206 scopus 로고
    • Effect of pulse-height selection on lesion detection performance
    • Roll FD, Schulz AG. Effect of pulse-height selection on lesion detection performance. J Nucl Med 1971; 12: 690-696.
    • (1971) J Nucl Med , vol.12 , pp. 690-696
    • Roll, F.D.1    Schulz, A.G.2
  • 4
    • 9844254435 scopus 로고
    • Effects of asymmetric photopeak windows on flood field uniformity and spatial resolution for scintillation cameras
    • LaFontaine R, Graham LS, Stein MA. Effects of asymmetric photopeak windows on flood field uniformity and spatial resolution for scintillation cameras. J Nucl Med 1984; 25: 893-900.
    • (1984) J Nucl Med , vol.25 , pp. 893-900
    • LaFontaine, R.1    Graham, L.S.2    Stein, M.A.3
  • 6
    • 0026528724 scopus 로고
    • A dual photopeak window method for scatter correction
    • King MA, Hademenos G, Click SJ. A dual photopeak window method for scatter correction. J Nucl Med 1992; 33: 605-612.
    • (1992) J Nucl Med , vol.33 , pp. 605-612
    • King, M.A.1    Hademenos, G.2    Click, S.J.3
  • 7
    • 0021679413 scopus 로고
    • Two- dimensional filtering of spect images using the metz and wiener filter
    • King MA, Schwinger RB, Doherty PW, Penney BC. Two- dimensional filtering of SPECT images using the Metz and Wiener filter. J Nucl Med 1984; 25: 1234-1240.
    • (1984) J Nucl Med , vol.25 , pp. 1234-1240
    • King, M.A.1    Schwinger, R.B.2    Doherty, P.W.3    Penney, B.C.4
  • 9
    • 0021260951 scopus 로고
    • Subtraction of compton- scattered photons in single photon emission computerized tomography
    • Axelsson B, Msaki P, Israelsson A. Subtraction of Compton- scattered photons in single photon emission computerized tomography. J Nucl Med 1984; 25: 490-494.
    • (1984) J Nucl Med , vol.25 , pp. 490-494
    • Axelsson, B.1    Msaki, P.2    Israelsson, A.3
  • 10
    • 0024997705 scopus 로고
    • Scatter and attenuation correction in spect using density maps and monte carlo simulated scatter functions
    • Ljungberg M, Strand S-E. Scatter and attenuation correction in SPECT using density maps and Monte Carlo simulated scatter functions. J Nucl Med 1990; 31: 1560-1567.
    • (1990) J Nucl Med , vol.31 , pp. 1560-1567
    • Ljungberg, M.1    Strand, S.-E.2
  • 11
    • 0027955827 scopus 로고
    • A transmission-dependent method for scatter correction in spect
    • Meikle SR, Hutton BF, Bailey DL. A transmission-dependent method for scatter correction in SPECT. J Nucl Med 1994; 35: 360-367.
    • (1994) J Nucl Med , vol.35 , pp. 360-367
    • Meikle, S.R.1    Hutton, B.F.2    Bailey, D.L.3
  • 12
    • 0017452940 scopus 로고
    • A method for attenuation correction in radionuclide computed tomography
    • NS-25
    • Chang LT. A method for attenuation correction in radionuclide computed tomography. IEEE Trails Nucl Sci 1978; NS-25: 638-643.
    • (1978) IEEE Trails Nucl Sci , pp. 638-643
    • Chang, L.T.1
  • 13
    • 0021282561 scopus 로고
    • Absolute quantitation of radioactivity using the buildup factor
    • Wu RK, Siegal JA. Absolute quantitation of radioactivity using the buildup factor. Med Phys 1984; 11: 189-192.
    • (1984) Med Phys , vol.11 , pp. 189-192
    • Wu, R.K.1    Siegal, J.A.2
  • 14
    • 0030422068 scopus 로고    scopus 로고
    • Scatter correction based on deconvolution method in spect. Icsp’96 conference proceedings
    • Yang J, Karjalainen P, Kuikka JT, Patomaki L. Scatter correction based on deconvolution method in SPECT. ICSP’96 Conference Proceedings, IEEE Signal Processing 1996, Vol. 1, pp. 501-504.
    • (1996) IEEE Signal Processing , vol.1 , pp. 501-504
    • Yang, J.1    Karjalainen, P.2    Kuikka, J.T.3    Patomaki, L.4
  • 15
    • 0029840927 scopus 로고    scopus 로고
    • Evaluation of spet quantification: Simultaneous emission and transmission imaging of the brain using a multidetector spet system with the tew scatter compensation method and fan-beam collimation
    • Ichihara T, Motomura N, Ogawa K, Hasegawa H, Hashimoto J, Kubo A. Evaluation of SPET quantification: Simultaneous emission and transmission imaging of the brain using a multidetector SPET system with the TEW scatter compensation method and fan-beam collimation. Eur J Nucl Med 1996; 23: 1292-1299.
    • (1996) Eur J Nucl Med , vol.23 , pp. 1292-1299
    • Ichihara, T.1    Motomura, N.2    Ogawa, K.3    Hasegawa, H.4    Hashimoto, J.5    Kubo, A.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.