-
1
-
-
0001599726
-
Stripping Analysis Combined On-Line with Inductively Coupled Plasma-Atomic Emission Spectrometry and with Inductively Coupled Plasma-Mass Spectrometry
-
Zhou F. Stripping Analysis Combined On-Line with Inductively Coupled Plasma-Atomic Emission Spectrometry and with Inductively Coupled Plasma-Mass Spectrometry. Electroanalysis 8 (1996) 855-861
-
(1996)
Electroanalysis
, vol.8
, pp. 855-861
-
-
Zhou, F.1
-
2
-
-
13944275508
-
Electrochemistry Combined On-Line with Atomic Mass Spectrometry and Related Techniques for Trace Metal Analysis and Studies of Electrode Reactions
-
Zhou F. Electrochemistry Combined On-Line with Atomic Mass Spectrometry and Related Techniques for Trace Metal Analysis and Studies of Electrode Reactions. Trends Anal. Chem. 24 (2005) 218-227
-
(2005)
Trends Anal. Chem.
, vol.24
, pp. 218-227
-
-
Zhou, F.1
-
3
-
-
0042489947
-
Electrochemical Preconcentration Technique for Use with Inductively Coupled Plasma Atomic Emission Spectrometry
-
Long S.E., and Snook R.D. Electrochemical Preconcentration Technique for Use with Inductively Coupled Plasma Atomic Emission Spectrometry. Analyst 108 (1983) 1331-1338
-
(1983)
Analyst
, vol.108
, pp. 1331-1338
-
-
Long, S.E.1
Snook, R.D.2
-
4
-
-
0037615113
-
Anodic Stripping Voltammetry Combined On-Line with Inductively Coupled Plasma via a Direct-Injection High-Efficiency Nebulizer
-
Baca A.J., De La Ree A.B., Zhou F., and Mason A.Z. Anodic Stripping Voltammetry Combined On-Line with Inductively Coupled Plasma via a Direct-Injection High-Efficiency Nebulizer. Anal. Chem. 75 (2003) 2507-2511
-
(2003)
Anal. Chem.
, vol.75
, pp. 2507-2511
-
-
Baca, A.J.1
De La Ree, A.B.2
Zhou, F.3
Mason, A.Z.4
-
5
-
-
0031235538
-
Anodic Stripping Voltammetry Coupled On-Line with Inductively Coupled Plasma Mass Spectrometry. Optimization of a Thin-Layer Flow Cell System for Analyte Signal Enhancement
-
Pretty J.R., Duckworth D.C., and Van Berkel G.J. Anodic Stripping Voltammetry Coupled On-Line with Inductively Coupled Plasma Mass Spectrometry. Optimization of a Thin-Layer Flow Cell System for Analyte Signal Enhancement. Anal. Chem. 69 (1997) 3544-3551
-
(1997)
Anal. Chem.
, vol.69
, pp. 3544-3551
-
-
Pretty, J.R.1
Duckworth, D.C.2
Van Berkel, G.J.3
-
6
-
-
0026063343
-
On-Line Electrolytic Dissolution of Alloys and Multielement Determination by Inductively Coupled Plasma Atomic Emission Spectrometry
-
Yuan D., Wang X., Yang P., and Huang B. On-Line Electrolytic Dissolution of Alloys and Multielement Determination by Inductively Coupled Plasma Atomic Emission Spectrometry. Anal. Chim. Acta 251 (1991) 187-190
-
(1991)
Anal. Chim. Acta
, vol.251
, pp. 187-190
-
-
Yuan, D.1
Wang, X.2
Yang, P.3
Huang, B.4
-
7
-
-
0000030804
-
Minimization of Sample Matrix Effects and Signal Enhancement for Trace Analytes Using Anodic Stripping Voltammetry with Detection by Inductively Coupled Plasma Atomic Emission Spectrometry and Inductively Coupled Plasma Mass Spectrometry
-
Pretty J.R., Evans E.H., Blubaugh E.A., Shen W.L., Caruso J.A., and Davidson T.M. Minimization of Sample Matrix Effects and Signal Enhancement for Trace Analytes Using Anodic Stripping Voltammetry with Detection by Inductively Coupled Plasma Atomic Emission Spectrometry and Inductively Coupled Plasma Mass Spectrometry. J. Anal. At. Spectrom. 5 (1990) 437-443
-
(1990)
J. Anal. At. Spectrom.
, vol.5
, pp. 437-443
-
-
Pretty, J.R.1
Evans, E.H.2
Blubaugh, E.A.3
Shen, W.L.4
Caruso, J.A.5
Davidson, T.M.6
-
8
-
-
0029512706
-
-
Morrow R.W., and Crain J.S. (Eds), American Society for Testing and Materials, West Conshohocken
-
Zhou F., Van Berkel G.J., Morton S.J., Duckworth D.C., Adeneiyi W.K., and Keller J.M. In: Morrow R.W., and Crain J.S. (Eds). Applications of Inductively Coupled Plasma-Mass Spectrometry to Radionuclide Determinations (1995), American Society for Testing and Materials, West Conshohocken 82-98
-
(1995)
Applications of Inductively Coupled Plasma-Mass Spectrometry to Radionuclide Determinations
, pp. 82-98
-
-
Zhou, F.1
Van Berkel, G.J.2
Morton, S.J.3
Duckworth, D.C.4
Adeneiyi, W.K.5
Keller, J.M.6
-
9
-
-
0001442457
-
Electrochemical Sample Pretreatment Coupled On-Line with ICP-MS. Analysis of Uranium Using an Anodically Conditioned Glassy Carbon Working Electrode
-
Pretty J.R., Duckworth D.C., and Van Berkel G.J. Electrochemical Sample Pretreatment Coupled On-Line with ICP-MS. Analysis of Uranium Using an Anodically Conditioned Glassy Carbon Working Electrode. Anal. Chem. 70 (1998) 1141-1148
-
(1998)
Anal. Chem.
, vol.70
, pp. 1141-1148
-
-
Pretty, J.R.1
Duckworth, D.C.2
Van Berkel, G.J.3
-
10
-
-
0035913890
-
Quantification of Metals Released by Metallothionein Adsorbates at Mercury Film Electrodes by Electrochemical ICP-Atomic Emission Spectrometry
-
Baca A.J., Garcia Y., Briseno A.L., and Zhou F. Quantification of Metals Released by Metallothionein Adsorbates at Mercury Film Electrodes by Electrochemical ICP-Atomic Emission Spectrometry. J. Electroanal. Chem. 513 (2001) 25-35
-
(2001)
J. Electroanal. Chem.
, vol.513
, pp. 25-35
-
-
Baca, A.J.1
Garcia, Y.2
Briseno, A.L.3
Zhou, F.4
-
11
-
-
0035899510
-
Quantification of Dopant Ions in Polypyrrole Films with Electrochemical ICP-Atomic Emission Spectrometry and Comparison to Electrochemical Quartz Crystal Microbalance Studies
-
Briseno A.L., Baca A.J., Zhou Q., Lai R., and Zhou F. Quantification of Dopant Ions in Polypyrrole Films with Electrochemical ICP-Atomic Emission Spectrometry and Comparison to Electrochemical Quartz Crystal Microbalance Studies. Anal. Chim. Acta 441 (2001) 123-124
-
(2001)
Anal. Chim. Acta
, vol.441
, pp. 123-124
-
-
Briseno, A.L.1
Baca, A.J.2
Zhou, Q.3
Lai, R.4
Zhou, F.5
-
12
-
-
0346855206
-
Adsorptive Stripping Voltammetry as a Sample Pretreatment Method for Trace Uranium Determinations by Inductively Coupled Plasma Mass Spectrometry
-
Pretty J.R., Van Berkel G.J., and Duckworth D.C. Adsorptive Stripping Voltammetry as a Sample Pretreatment Method for Trace Uranium Determinations by Inductively Coupled Plasma Mass Spectrometry. Int. J. Mass Spectrom. Ion Processes 178 (1998) 51-63
-
(1998)
Int. J. Mass Spectrom. Ion Processes
, vol.178
, pp. 51-63
-
-
Pretty, J.R.1
Van Berkel, G.J.2
Duckworth, D.C.3
-
13
-
-
0001117012
-
Determination of Copper and Cadmium Using an On-Line Anodic Stripping Voltammetry Flow Cell with Detection by Inductively Coupled Plasma Mass Spectrometry
-
Pretty J.R., Blubaugh E.A., and Caruso J.A. Determination of Copper and Cadmium Using an On-Line Anodic Stripping Voltammetry Flow Cell with Detection by Inductively Coupled Plasma Mass Spectrometry. J. Anal. At. Spectrom. 7 (1992) 1131-1137
-
(1992)
J. Anal. At. Spectrom.
, vol.7
, pp. 1131-1137
-
-
Pretty, J.R.1
Blubaugh, E.A.2
Caruso, J.A.3
-
14
-
-
0027711719
-
Determination of Arsenic(III) and Selenium(IV) Using an On-Line Anodic Stripping Voltammetry Flow Cell with Detection by Inductively Coupled Plasma Atomic Emission Spectrometry and Inductively Coupled Plasma Mass Spectrometry
-
Pretty J.R., Blubaugh E.A., and Caruso J.A. Determination of Arsenic(III) and Selenium(IV) Using an On-Line Anodic Stripping Voltammetry Flow Cell with Detection by Inductively Coupled Plasma Atomic Emission Spectrometry and Inductively Coupled Plasma Mass Spectrometry. Anal. Chem. 65 (1993) 3396-3404
-
(1993)
Anal. Chem.
, vol.65
, pp. 3396-3404
-
-
Pretty, J.R.1
Blubaugh, E.A.2
Caruso, J.A.3
-
15
-
-
37049076877
-
Signal Enhancement of Lead and Thallium in Inductively Coupled Plasma Atomic Emission Spectrometry Using On-Line Anodic Stripping Voltammetry
-
Pretty J.R., and Caruso J.A. Signal Enhancement of Lead and Thallium in Inductively Coupled Plasma Atomic Emission Spectrometry Using On-Line Anodic Stripping Voltammetry. J. Anal. At. Spectrom. 8 (1993) 545-550
-
(1993)
J. Anal. At. Spectrom.
, vol.8
, pp. 545-550
-
-
Pretty, J.R.1
Caruso, J.A.2
-
16
-
-
0001469076
-
Determination of Chromium(VI) and Vanadium(V) Using an On-Line Anodic Stripping Voltammetry Flow Cell with Detection by Inductively Coupled Plasma Mass Spectrometry
-
Pretty J.R., Blubaugh E.A., Caruso J.A., and Davidson T.M. Determination of Chromium(VI) and Vanadium(V) Using an On-Line Anodic Stripping Voltammetry Flow Cell with Detection by Inductively Coupled Plasma Mass Spectrometry. Anal. Chem. 66 (1994) 1540-1547
-
(1994)
Anal. Chem.
, vol.66
, pp. 1540-1547
-
-
Pretty, J.R.1
Blubaugh, E.A.2
Caruso, J.A.3
Davidson, T.M.4
-
18
-
-
33745253847
-
-
Barshick C.M., Duckworth D.C., and Smith D.H. (Eds), Marcel Dekker, New York
-
Olesik J.W. In: Barshick C.M., Duckworth D.C., and Smith D.H. (Eds). Inorganic Mass Spectrometry (2000), Marcel Dekker, New York 91-92
-
(2000)
Inorganic Mass Spectrometry
, pp. 91-92
-
-
Olesik, J.W.1
-
20
-
-
0003430766
-
-
VCH, Deerfield, FL
-
Wang J. Stripping Analysis. Principles, Instrumentation, and Applications (1985), VCH, Deerfield, FL 48-51
-
(1985)
Stripping Analysis. Principles, Instrumentation, and Applications
, pp. 48-51
-
-
Wang, J.1
-
21
-
-
0031728859
-
Electrochemical Sample Pretreatment Coupled On-Line with Electrospray Mass Spectrometry for Enhanced Elemental Analysis
-
Pretty J.R., and Van Berkel G.J. Electrochemical Sample Pretreatment Coupled On-Line with Electrospray Mass Spectrometry for Enhanced Elemental Analysis. Rapid Commun. Mass Spectrom. 12 (1998) 1644-1652
-
(1998)
Rapid Commun. Mass Spectrom.
, vol.12
, pp. 1644-1652
-
-
Pretty, J.R.1
Van Berkel, G.J.2
-
22
-
-
0000527148
-
Electrochemistry Combined On-Line with Electrospray Mass Spectrometry
-
Zhou F., and Van Berkel G.J. Electrochemistry Combined On-Line with Electrospray Mass Spectrometry. Anal. Chem. 67 (1995) 3643-3649
-
(1995)
Anal. Chem.
, vol.67
, pp. 3643-3649
-
-
Zhou, F.1
Van Berkel, G.J.2
-
23
-
-
0037059416
-
Electrochemistry-Electrospray-Mass Spectrometry Study of Cesium Uptake in Nickel Hexacyanoferrate Films
-
Kertesz V., Dunn N.M., and Van Berkel G.J. Electrochemistry-Electrospray-Mass Spectrometry Study of Cesium Uptake in Nickel Hexacyanoferrate Films. Electrochim. Acta 47 (2002) 1035-1042
-
(2002)
Electrochim. Acta
, vol.47
, pp. 1035-1042
-
-
Kertesz, V.1
Dunn, N.M.2
Van Berkel, G.J.3
-
24
-
-
0000996760
-
Direct Injection Nebulization for Inductively Coupled Plasma Mass Spectrometry
-
Wiederin D.R., Smith F.G., and Houk R.S. Direct Injection Nebulization for Inductively Coupled Plasma Mass Spectrometry. Anal Chem. 63 (1991) 219-225
-
(1991)
Anal Chem.
, vol.63
, pp. 219-225
-
-
Wiederin, D.R.1
Smith, F.G.2
Houk, R.S.3
-
25
-
-
0033706030
-
The Determination of Cr in Human Lung Fibroblast Cells Using a Large Bore Direct Injection High Efficiency Nebulizer with Inductively Coupled Plasma Mass Spectrometry
-
McLean J.A., Acon B.W., Montaser A., Singh J., Pritchard D.L., and Patierno S.R. The Determination of Cr in Human Lung Fibroblast Cells Using a Large Bore Direct Injection High Efficiency Nebulizer with Inductively Coupled Plasma Mass Spectrometry. Appl. Spectrosc. 54 (2000) 659-663
-
(2000)
Appl. Spectrosc.
, vol.54
, pp. 659-663
-
-
McLean, J.A.1
Acon, B.W.2
Montaser, A.3
Singh, J.4
Pritchard, D.L.5
Patierno, S.R.6
-
26
-
-
0034272147
-
Direct Injection High Efficiency Nebulization in Inductively Coupled Plasma Mass Spectrometry Under Normal and Cool Plasma Conditions
-
Minnich M.G., and Montaser A. Direct Injection High Efficiency Nebulization in Inductively Coupled Plasma Mass Spectrometry Under Normal and Cool Plasma Conditions. Appl. Spectrosc. 54 (2000) 1261-1269
-
(2000)
Appl. Spectrosc.
, vol.54
, pp. 1261-1269
-
-
Minnich, M.G.1
Montaser, A.2
-
27
-
-
0037350774
-
Mercury Film Electrodes. Developments, Trends, and Potentialities for Electroanalysis
-
Economou A., and Fielden P.R. Mercury Film Electrodes. Developments, Trends, and Potentialities for Electroanalysis. Analyst 128 (2003) 205-212
-
(2003)
Analyst
, vol.128
, pp. 205-212
-
-
Economou, A.1
Fielden, P.R.2
-
28
-
-
0023475432
-
Application of Polymer-Coated Glassy Carbon Electrodes to the Direct Determination of Trace Metals in Body Fluids by Anodic Stripping Voltammetry
-
Hoyer B., and Florence T.M. Application of Polymer-Coated Glassy Carbon Electrodes to the Direct Determination of Trace Metals in Body Fluids by Anodic Stripping Voltammetry. Anal. Chem. 59 (1987) 2839-2842
-
(1987)
Anal. Chem.
, vol.59
, pp. 2839-2842
-
-
Hoyer, B.1
Florence, T.M.2
-
29
-
-
0001408007
-
Signal Stability of Nafion-Coated Thin Mercury Film Electrodes for Stripping Voltammetry
-
Hoyer B., and Jensen N. Signal Stability of Nafion-Coated Thin Mercury Film Electrodes for Stripping Voltammetry. Talanta 41 (1994) 449-453
-
(1994)
Talanta
, vol.41
, pp. 449-453
-
-
Hoyer, B.1
Jensen, N.2
-
30
-
-
0001467578
-
Ultrasound-enhanced Anodic Stripping Voltammetry Using Perfluorosulfonated Ionomer-Coated Mercury Thin-Film Electrodes
-
Matysik F.M., Matysik S., Oliveira-Brett A.M., and Brett C.M.A. Ultrasound-enhanced Anodic Stripping Voltammetry Using Perfluorosulfonated Ionomer-Coated Mercury Thin-Film Electrodes. Anal. Chem. 69 (1997) 1651-1656
-
(1997)
Anal. Chem.
, vol.69
, pp. 1651-1656
-
-
Matysik, F.M.1
Matysik, S.2
Oliveira-Brett, A.M.3
Brett, C.M.A.4
-
31
-
-
8844265305
-
A Study of Nafion-Coated Bismuth-Film Electrodes for the Determination of Trace Metals by Anodic Stripping Voltammetry
-
Kefala G., Economou A., and Voulgaropoulos A. A Study of Nafion-Coated Bismuth-Film Electrodes for the Determination of Trace Metals by Anodic Stripping Voltammetry. Analyst 129 (2004) 1-20
-
(2004)
Analyst
, vol.129
, pp. 1-20
-
-
Kefala, G.1
Economou, A.2
Voulgaropoulos, A.3
-
32
-
-
0034661524
-
Bismuth-Coated Carbon Electrodes for Anodic Stripping Voltammetry
-
Wang J., Lu J., Hocevar S.B., and Farias P.A.M. Bismuth-Coated Carbon Electrodes for Anodic Stripping Voltammetry. Anal. Chem. 72 (2000) 3218-3222
-
(2000)
Anal. Chem.
, vol.72
, pp. 3218-3222
-
-
Wang, J.1
Lu, J.2
Hocevar, S.B.3
Farias, P.A.M.4
-
33
-
-
0034757866
-
Effect of Surface-Active Compounds on the Stripping Voltammetric Response of Bismuth Film Electrodes
-
Wang J., Deo R.P., Thongngamdee S., and Ogorevc B. Effect of Surface-Active Compounds on the Stripping Voltammetric Response of Bismuth Film Electrodes. Electroanalysis 13 (2001) 1153-1156
-
(2001)
Electroanalysis
, vol.13
, pp. 1153-1156
-
-
Wang, J.1
Deo, R.P.2
Thongngamdee, S.3
Ogorevc, B.4
-
34
-
-
0035946383
-
Insights into the Anodic Stripping Voltammetric Behavior of Bismuth Film Electrodes
-
Wang J., Lu J., Kirgoz U.A., Hocevar S.B., and Ogorevc B. Insights into the Anodic Stripping Voltammetric Behavior of Bismuth Film Electrodes. Anal. Chim. Acta 434 (2001) 29-34
-
(2001)
Anal. Chim. Acta
, vol.434
, pp. 29-34
-
-
Wang, J.1
Lu, J.2
Kirgoz, U.A.3
Hocevar, S.B.4
Ogorevc, B.5
-
35
-
-
0242413850
-
A Study of Bismuth-Film Electrodes for the Detection of Trace Metals by Anodic Stripping Voltammetry and Their Application to the Determination of Pb and Zn in Tap Water and Human Hair
-
Kefala G., Economou A., Voulgaropoulos A., and Sofoniou M. A Study of Bismuth-Film Electrodes for the Detection of Trace Metals by Anodic Stripping Voltammetry and Their Application to the Determination of Pb and Zn in Tap Water and Human Hair. Talanta 61 (2003) 603-610
-
(2003)
Talanta
, vol.61
, pp. 603-610
-
-
Kefala, G.1
Economou, A.2
Voulgaropoulos, A.3
Sofoniou, M.4
-
36
-
-
16244410840
-
Sonoelectroanalysis. Investigation of Bismuth-Film-Modified Glassy Carbon Electrodes
-
Banks C.E., Kruusma J., Hyde M.E., Salimi A., and Compton R.G. Sonoelectroanalysis. Investigation of Bismuth-Film-Modified Glassy Carbon Electrodes. Anal. Bioanal. Chem. 379 (2004) 277-282
-
(2004)
Anal. Bioanal. Chem.
, vol.379
, pp. 277-282
-
-
Banks, C.E.1
Kruusma, J.2
Hyde, M.E.3
Salimi, A.4
Compton, R.G.5
-
37
-
-
21744461150
-
The Use of Nafion-Coated Thin Mercury Film Electrodes for the Determination of the Dissolved Copper Speciation in Estuarine Water
-
Hurst M.P., and Bruland K.W. The Use of Nafion-Coated Thin Mercury Film Electrodes for the Determination of the Dissolved Copper Speciation in Estuarine Water. Anal. Chim. Acta 546 (2005) 68-78
-
(2005)
Anal. Chim. Acta
, vol.546
, pp. 68-78
-
-
Hurst, M.P.1
Bruland, K.W.2
-
38
-
-
0035852045
-
Nafion. An Excellent Support for Metal-complex Catalysts
-
Seen A.J. Nafion. An Excellent Support for Metal-complex Catalysts. J. Mol. Catal. 177 (2001) 105-112
-
(2001)
J. Mol. Catal.
, vol.177
, pp. 105-112
-
-
Seen, A.J.1
-
39
-
-
47049085857
-
Nafion-Coated Mercury-Coated Glassy Carbon Electrodes for Metals Analysis and Speciation
-
Guy R.D., and Namaratne S. Nafion-Coated Mercury-Coated Glassy Carbon Electrodes for Metals Analysis and Speciation. Can. J. Chem. 65 (1987) 1133-1138
-
(1987)
Can. J. Chem.
, vol.65
, pp. 1133-1138
-
-
Guy, R.D.1
Namaratne, S.2
-
41
-
-
3342900320
-
Electrochemistry/Mass Spectrometry (EC/MS)-A New Tool to Study Drug Metabolism and Reaction Mechanisms
-
Karst U. Electrochemistry/Mass Spectrometry (EC/MS)-A New Tool to Study Drug Metabolism and Reaction Mechanisms. Angew. Chem. Int. Ed. 43 (2004) 2476-2478
-
(2004)
Angew. Chem. Int. Ed.
, vol.43
, pp. 2476-2478
-
-
Karst, U.1
-
42
-
-
0002991056
-
Electrochemistry On-Line with Mass Spectrometry. Insight into Biological Redox Reactions
-
Volk K.J., Yost R.A., and Brajter-Toth A. Electrochemistry On-Line with Mass Spectrometry. Insight into Biological Redox Reactions. Anal. Chem. 64 (1992) 21A-33A
-
(1992)
Anal. Chem.
, vol.64
-
-
Volk, K.J.1
Yost, R.A.2
Brajter-Toth, A.3
-
43
-
-
0024710349
-
On-Line Electrochemistry/Thermospray/Tandem Mass Spectrometry as a New Approach to the Study of Redox Reactions. The Oxidation of Uric Acid
-
Volk K.J., Yost R.A., and Brajter-Toth A. On-Line Electrochemistry/Thermospray/Tandem Mass Spectrometry as a New Approach to the Study of Redox Reactions. The Oxidation of Uric Acid. Anal. Chem. 61 (1989) 1709-1717
-
(1989)
Anal. Chem.
, vol.61
, pp. 1709-1717
-
-
Volk, K.J.1
Yost, R.A.2
Brajter-Toth, A.3
|