메뉴 건너뛰기




Volumn 26, Issue 8, 2006, Pages 124-127

Comparison of the AC pollution flashover characteristics of insulators under two different polluting manners

Author keywords

Flashover characteristic; Polluting manners; Pollution insulator; Power system

Indexed keywords

CONTAMINATION; ELECTRIC POWER SYSTEMS; FLASHOVER; FOG;

EID: 33745176214     PISSN: 02588013     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (21)

References (15)
  • 1
    • 85009310370 scopus 로고    scopus 로고
    • Chinese source
  • 3
    • 0024087904 scopus 로고
    • Variable voltage application for insulator pollution tests
    • Lambeth P J. Variable voltage application for insulator pollution tests[J]. IEEE Transaction on Power Delivery, 1988, 3(4): 2103-2111.
    • (1988) IEEE Transaction on Power Delivery , vol.3 , Issue.4 , pp. 2103-2111
    • Lambeth, P.J.1
  • 5
    • 0028378912 scopus 로고
    • Effect of insulator profiles on DC flashover voltage under polluted conditions
    • Sundararajan R. Effect of insulator profiles on DC flashover voltage under polluted conditions[J]. IEEE Transactions on Dielectrics and Electrical Insulations, 1994, 1(1): 124-132.
    • (1994) IEEE Transactions on Dielectrics and Electrical Insulations , vol.1 , Issue.1 , pp. 124-132
    • Sundararajan, R.1
  • 6
    • 23444457614 scopus 로고    scopus 로고
    • AC pollution flashover performance and comparison of short samples of 750 kV composite insulators with different configuration in high altitude area
    • Chinese source
    • Jiang Xingliang, Zhang Zhijin, Hu Jianlin, et al. AC pollution flashover performance and comparison of short samples of 750 kV composite insulators with different configuration in high altitude area[J]. Proceeding of the CSEE, 2005, 25(12): 159-164(in Chinese).
    • (2005) Proceeding of the CSEE , vol.25 , Issue.12 , pp. 159-164
    • Jiang, X.1    Zhang, Z.2    Hu, J.3
  • 7
    • 0036872739 scopus 로고    scopus 로고
    • AC/DC flashover performance and its voltage correction of UHV insulators in high altitude and icing and pollution environments
    • Chinese source
    • Sun Caixin, Jiang Xingliang, Shu Lichun. et al.. (AC/DC flashover performance and its voltage correction of UHV insulators in high altitude and icing and pollution environments[J]. Proceedings of the CSEE, 2002, 22(11): 115-120(in Chinese).
    • (2002) Proceedings of the CSEE , vol.22 , Issue.11 , pp. 115-120
    • Sun, C.1    Jiang, X.2    Shu, L.3
  • 8
    • 4344688097 scopus 로고    scopus 로고
    • DC electrical performance of icing and polluted 10 kV composite insulator at low atmospheric pressures
    • Chinese source
    • Sima Wenxia, Jiang Xingliang, Wu Lihui, et al.. DC electrical performance of icing and polluted 10 kV composite insulator at low atmospheric pressures[J]. Proceedings of the CSEE, 2004, 24(7): 122-126(in Chinese).
    • (2004) Proceedings of the CSEE , vol.24 , Issue.7 , pp. 122-126
    • Sima, W.1    Jiang, X.2    Wu, L.3
  • 9
    • 0035322397 scopus 로고    scopus 로고
    • The research to token on flashover characteristics of insulator in the acid wet precipitation
    • Chinese source
    • Yu Defen, Gu Leguan, Sun Caixin, et al. The research to token on flashover characteristics of insulator in the acid wet precipitation[J]. Proceedings of the CSEE, 2001, 21(4): 15-19(in Chinese).
    • (2001) Proceedings of the CSEE , vol.21 , Issue.4 , pp. 15-19
    • Yu, D.1    Gu, L.2    Sun, C.3
  • 10
    • 3142720700 scopus 로고    scopus 로고
    • Comparison of natural contaminants accumulated on surfaces of suspension and post insulators with DC and AC stress in northern China's inland areas
    • Chinese source
    • Su Zhiyi, Liu Yansheng. Comparison of natural contaminants accumulated on surfaces of suspension and post insulators with DC and AC stress in northern China's inland areas[J]. Power System Technology, 2004, 28(10): 13-17(in Chinese).
    • (2004) Power System Technology , vol.28 , Issue.10 , pp. 13-17
    • Su, Z.1    Liu, Y.2
  • 11
    • 0034172056 scopus 로고    scopus 로고
    • Study on the method of ESDD on site measurement
    • Chinese source
    • Jiang Xiucheng, An Ling, Han Zhendong, et al. Study on the method of ESDD on site measurement[J]. Proceedings of the CSEE, 2000, 20(4): 40-44(in Chinese).
    • (2000) Proceedings of the CSEE , vol.20 , Issue.4 , pp. 40-44
    • Jiang, X.1    An, L.2    Han, Z.3
  • 12
    • 2542458386 scopus 로고    scopus 로고
    • Study on defining pollution classes and mapping, pollution areas by saturated equal salt deposit density
    • Chinese source
    • Su Zhiyi. Study on defining pollution classes and mapping, pollution areas by saturated equal salt deposit density[J]. Power System Technology, 2004, 28(8): 16-19(in Chinese).
    • (2004) Power System Technology , vol.28 , Issue.8 , pp. 16-19
    • Su, Z.1
  • 13
    • 0029754375 scopus 로고    scopus 로고
    • Influence of nonsoluble contaminants on the flashover voltages of artificially contaminated insulators
    • Matsuoka R, Kondo K. Influence of nonsoluble contaminants on the flashover voltages of artificially contaminated insulators[J]. IEEE Transactions on Power Delivery, 1996, 11(1): 420-430.
    • (1996) IEEE Transactions on Power Delivery , vol.11 , Issue.1 , pp. 420-430
    • Matsuoka, R.1    Kondo, K.2
  • 14
    • 33745121642 scopus 로고    scopus 로고
    • Artificial pollution tests on high-voltage insulators to be used on AC systems
    • Chinese source
    • Artificial pollution tests on high-voltage insulators to be used on AC systems[S](in Chinese).
  • 15
    • 33745121642 scopus 로고    scopus 로고
    • Artificial pollution tests on high-voltage insulators to be used on AC systems
    • IEC 60507-1991
    • IEC 60507-1991. Artificial pollution tests on high-voltage insulators to be used on AC systems[S].


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.