메뉴 건너뛰기




Volumn 6146, Issue , 2006, Pages

Characterization of a new generation of Computed Radiography system based on line scanning and phosphor needles

Author keywords

Clinical validation; Contrast detail; CR; MTF; Noise; Phosphor needles; SNR

Indexed keywords

DOSIMETRY; MEDICAL APPLICATIONS; MEDICAL IMAGING; PHOSPHORS; SIGNAL TO NOISE RATIO; SPURIOUS SIGNAL NOISE;

EID: 33745165592     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.655494     Document Type: Conference Paper
Times cited : (3)

References (10)
  • 1
    • 0004016159 scopus 로고    scopus 로고
    • Criteria for the acceptability of radiological (including radiotherapy) and nuclear medicine installations
    • Criteria for the acceptability of radiological (including radiotherapy) and nuclear medicine installations. Report 91 of the European Commission, 1997.
    • (1997) Report 91 of the European Commission
  • 2
    • 0041935939 scopus 로고    scopus 로고
    • U. S. National Institutes of Health, Bethesda, Maryland, USA
    • Rasband, W.S., ImageJ, U. S. National Institutes of Health, Bethesda, Maryland, USA, http://rsb.info.nih.gov/ij/, 1997-2006.
    • (1997) ImageJ
    • Rasband, W.S.1
  • 5
    • 0036032131 scopus 로고    scopus 로고
    • A practical method for Detected Quantum Efficiency (DQE) assessment of digital mammography systems in the radiological environment
    • Medical Imaging 2002
    • Frank Rogge, Dirk Vandenbroucke, Luc Struye, Hilde Bosmans, Peter Willems, Guy Marchal. "A Practical Method for Detected Quantum Efficiency (DQE) Assessment of Digital Mammography Systems in the Radiological Environment". Proc. SPIE Vol. 4682, p. 645-655, Medical Imaging 2002
    • Proc. SPIE , vol.4682 , pp. 645-655
    • Rogge, F.1    Vandenbroucke, D.2    Struye, L.3    Bosmans, H.4    Willems, P.5    Marchal, G.6
  • 6
    • 0031950889 scopus 로고    scopus 로고
    • A method for measuring the presampled MTF of digital radiographic systems using an edge test device
    • E. Samei, M.J. Flynn, D.A. Reimann, "A method for measuring the presampled MTF of digital radiographic systems using an edge test device", Medical Physics, 25, p. 102-113, 1998.
    • (1998) Medical Physics , vol.25 , pp. 102-113
    • Samei, E.1    Flynn, M.J.2    Reimann, D.A.3
  • 7
    • 33745133326 scopus 로고    scopus 로고
    • March, revision 2
    • http://www.flukebiomedical.com/RMS/productManuals/AAPM-31-1.pdf, March 2005, revision 2.
    • (2005)
  • 9
    • 0038372096 scopus 로고    scopus 로고
    • The value of scatter removal by a grid in full field digital mammography
    • W. Veldkamp, M. Thijssen, N. Karssemeijer, "The value of scatter removal by a grid in full field digital mammography", Medical Physics., 30, pp. 1712-1718, 2003.
    • (2003) Medical Physics , vol.30 , pp. 1712-1718
    • Veldkamp, W.1    Thijssen, M.2    Karssemeijer, N.3
  • 10
    • 33745416524 scopus 로고    scopus 로고
    • Comparison of software and human observers in reading images of the CDMAM test object to assess digital mammography systems
    • Kenneth C. Young, James J.H. Cook, Jennifer M. Oduko, Hilde Bosmans. "Comparison of software and human observers in reading images of the CDMAM test object to assess digital mammography systems" Proc. SPIE 2006.
    • Proc. SPIE 2006
    • Young, K.C.1    Cook, J.J.H.2    Oduko, J.M.3    Bosmans, H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.