메뉴 건너뛰기




Volumn 135, Issue 2, 2006, Pages 272-275

Rapid detection and typing of influenza A and B by loop-mediated isothermal amplification: Comparison with immunochromatography and virus isolation

Author keywords

Immunochromatograly test; Influenza virus; Loop mediated isothermal amplification (LAMP); Virus isolation

Indexed keywords

ANALYTIC METHOD; ARTICLE; ASPIRATION; CHILD; CHROMATOGRAPHY; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; EPIDEMIC; FEMALE; HEMAGGLUTINATION INHIBITION TEST; HUMAN; INFANT; INFLUENZA; INFLUENZA VIRUS A; INFLUENZA VIRUS B; INTERMETHOD COMPARISON; LOOP MEDIATED ISOTHERMAL AMPLIFICATION; MAJOR CLINICAL STUDY; MALE; NASOPHARYNX; PRIORITY JOURNAL; RNA EXTRACTION; VIRUS DETECTION; VIRUS ISOLATION; VIRUS STRAIN; VIRUS TYPING;

EID: 33745161799     PISSN: 01660934     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jviromet.2006.03.003     Document Type: Article
Times cited : (75)

References (15)
  • 1
    • 0019470002 scopus 로고
    • An evaluation of influenza mortality surveillance, 1962-1979. I. Time series forecasts of expected pneumonia and influenza death
    • Choi K., and Thacker S.B. An evaluation of influenza mortality surveillance, 1962-1979. I. Time series forecasts of expected pneumonia and influenza death. Am. J. Epidemiol. 113 (1981) 215-226
    • (1981) Am. J. Epidemiol. , vol.113 , pp. 215-226
    • Choi, K.1    Thacker, S.B.2
  • 2
    • 0019431789 scopus 로고
    • An evaluation of influenza mortality surveillance, 1962-1979. II. Percentage of pneumonia and influenza deaths as an indicator of influenza activity
    • Choi K., and Thacker S.B. An evaluation of influenza mortality surveillance, 1962-1979. II. Percentage of pneumonia and influenza deaths as an indicator of influenza activity. Am. J. Epidemiol. 113 (1981) 227-235
    • (1981) Am. J. Epidemiol. , vol.113 , pp. 227-235
    • Choi, K.1    Thacker, S.B.2
  • 3
    • 20044387604 scopus 로고    scopus 로고
    • A simple method for the detection of measles virus genome by loop-mediated isothermal amplification (LAMP)
    • Fujino M., Yoshida N., Yamaguchi S., Hosaka N., Ota Y., Notomi T., and Nakayama T. A simple method for the detection of measles virus genome by loop-mediated isothermal amplification (LAMP). J. Med. Virol. 76 (2005) 406-413
    • (2005) J. Med. Virol. , vol.76 , pp. 406-413
    • Fujino, M.1    Yoshida, N.2    Yamaguchi, S.3    Hosaka, N.4    Ota, Y.5    Notomi, T.6    Nakayama, T.7
  • 6
    • 0038519306 scopus 로고    scopus 로고
    • Loop-mediated isothermal amplification for direct detection of Mycobacterium tuberculosis Complex, M. Avium, and M. intracellulare in sputum samples
    • Iwamoto T., Sonobe T., and Hayashi K. Loop-mediated isothermal amplification for direct detection of Mycobacterium tuberculosis Complex, M. Avium, and M. intracellulare in sputum samples. J. Clin. Microbiol. 41 (2003) 2616-2622
    • (2003) J. Clin. Microbiol. , vol.41 , pp. 2616-2622
    • Iwamoto, T.1    Sonobe, T.2    Hayashi, K.3
  • 8
    • 0036720453 scopus 로고    scopus 로고
    • Encephalitis and encephalopathy associated with an influenza epidemic in Japan
    • Collaborative Study Group on Influenza-Associated Encephalopathy in Japan
    • Morishima T., Togashi T., Yokota S., Okuno Y., Miyazaki C., Tashiro M., Okabe N., and Collaborative Study Group on Influenza-Associated Encephalopathy in Japan. Encephalitis and encephalopathy associated with an influenza epidemic in Japan. Clin. Infect. Dis. 35 (2002) 512-517
    • (2002) Clin. Infect. Dis. , vol.35 , pp. 512-517
    • Morishima, T.1    Togashi, T.2    Yokota, S.3    Okuno, Y.4    Miyazaki, C.5    Tashiro, M.6    Okabe, N.7
  • 9
    • 0032961433 scopus 로고    scopus 로고
    • Rapid detection and identification of two lineages of influenza B strains with monoclonal antibodies
    • Nakagawa N., Maeda A., Kase T., Kubota R., and Okuno Y. Rapid detection and identification of two lineages of influenza B strains with monoclonal antibodies. J. Virol. Methods 79 (1999) 113-120
    • (1999) J. Virol. Methods , vol.79 , pp. 113-120
    • Nakagawa, N.1    Maeda, A.2    Kase, T.3    Kubota, R.4    Okuno, Y.5
  • 11
    • 7044229551 scopus 로고    scopus 로고
    • Rapid detection of varicella-zoster virus infection by a loop-mediated isothermal amplification method
    • Okamoto S., Yoshikawa T., Ihira M., Suzuki K., Shimokata K., Nishiyama Y., and Asano Y. Rapid detection of varicella-zoster virus infection by a loop-mediated isothermal amplification method. J. Med. Virol. 74 (2004) 677-682
    • (2004) J. Med. Virol. , vol.74 , pp. 677-682
    • Okamoto, S.1    Yoshikawa, T.2    Ihira, M.3    Suzuki, K.4    Shimokata, K.5    Nishiyama, Y.6    Asano, Y.7
  • 12
    • 0025324564 scopus 로고
    • Rapid focus reduction neutralization test of influenza A and B viruses in microtiter system
    • Okuno Y., Tanaka K., Baba K., Maeda A., Kunita N., and Ueda S. Rapid focus reduction neutralization test of influenza A and B viruses in microtiter system. J. Clin. Microbiol. 28 (1990) 1308-1313
    • (1990) J. Clin. Microbiol. , vol.28 , pp. 1308-1313
    • Okuno, Y.1    Tanaka, K.2    Baba, K.3    Maeda, A.4    Kunita, N.5    Ueda, S.6
  • 13
    • 2442521378 scopus 로고    scopus 로고
    • Development and evaluation of a novel loop-mediated isothermal amplification of method for rapid detection of severe acute respiratory syndrome coronavirus
    • Thai H.T.C., Le M.Q., Vuong C.D., Parida M., Minekawa H., Notomi T., Hasebe F., and Morita K. Development and evaluation of a novel loop-mediated isothermal amplification of method for rapid detection of severe acute respiratory syndrome coronavirus. J. Clin. Microbiol. 42 (2004) 1956-1961
    • (2004) J. Clin. Microbiol. , vol.42 , pp. 1956-1961
    • Thai, H.T.C.1    Le, M.Q.2    Vuong, C.D.3    Parida, M.4    Minekawa, H.5    Notomi, T.6    Hasebe, F.7    Morita, K.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.