메뉴 건너뛰기




Volumn 27, Issue 5, 2006, Pages

Parametric EIT for monitoring cardiac stroke volume

Author keywords

Clinical trial; Parametric reconstruction; Simulation study; SV measurement

Indexed keywords

ELECTRIC IMPEDANCE TOMOGRAPHY; ELECTROCARDIOGRAPHY; MAGNETIC RESONANCE IMAGING; PARAMETER ESTIMATION; SIGNAL TO NOISE RATIO;

EID: 33745153794     PISSN: 09673334     EISSN: 13616579     Source Type: Journal    
DOI: 10.1088/0967-3334/27/5/S12     Document Type: Conference Paper
Times cited : (50)

References (12)
  • 1
    • 0028624694 scopus 로고
    • Numerical calculation of the potential distribution due to dipole sources in a spherical model of the head
    • Abboud S, Eshel Y, Levy S and Rosenfeld M 1994 Numerical calculation of the potential distribution due to dipole sources in a spherical model of the head Comput. Biomed. Res. 27 441-55
    • (1994) Comput. Biomed. Res. , vol.27 , Issue.6 , pp. 441-455
    • Abboud, S.1    Eshel, Y.2    Levy, S.3    Rosenfeld, M.4
  • 2
    • 33745149905 scopus 로고    scopus 로고
    • Boese J M, Bahner M L, Albers J and Schad L R 2005 Computed tomography of the heart with high temporal resolution using retrospective cardiac gating, from: www.dkfz-heidelberg.de/mrphys/heart/ct/ekgct.html
    • (2005)
    • Boese, J.M.1    Bahner, M.L.2    Albers, J.3    Schad, L.R.4
  • 4
    • 33745125881 scopus 로고    scopus 로고
    • Gabriel C, Andreuccetti D, Fossi R and Petrucci C 2005 An internet resource for the calculation of the dielectric properties of body tissues, from: http://niremf.iroe.fi.cnr.it/tissprop/
    • (2005)
    • Gabriel, C.1    Andreuccetti, D.2    Fossi, R.3    Petrucci, C.4
  • 5
    • 84981642933 scopus 로고
    • Impedance cardiography as a non-invasive method to monitor cardiac function and other parameters of the cardiovascular system
    • Kubicek W G, Patterson R P and Witsoe D A 1970 Impedance cardiography as a non-invasive method to monitor cardiac function and other parameters of the cardiovascular system Ann. NY Acad. Sci. 170 724-32
    • (1970) Ann. NY Acad. Sci. , vol.170 , pp. 724-732
    • Kubicek, W.G.1    Patterson, R.P.2    Witsoe, D.A.3
  • 6
    • 2442688872 scopus 로고    scopus 로고
    • Recent developments in cardiac output determination by bioimpedance: Comparison with invasive cardiac output and potential cardiovascular applications
    • Moshkovitz Y, Kaluski E, Milo O, Vered Z and Cotter G 2004 Recent developments in cardiac output determination by bioimpedance: comparison with invasive cardiac output and potential cardiovascular applications Curr. Opin. Cardiol. 19 229-37
    • (2004) Curr. Opin. Cardiol. , vol.19 , pp. 229-237
    • Moshkovitz, Y.1    Kaluski, E.2    Milo, O.3    Vered, Z.4    Cotter, G.5
  • 8
    • 0032765191 scopus 로고    scopus 로고
    • The non-invasive assessment of stroke volume and cardiac output by impedance cardiography: A review
    • Newman D G and Callister R 1999 The non-invasive assessment of stroke volume and cardiac output by impedance cardiography: a review Aviat. Space Environ. Med. 70 780-9
    • (1999) Aviat. Space Environ. Med. , vol.70 , pp. 780-789
    • Newman, D.G.1    Callister, R.2
  • 9
    • 0029239605 scopus 로고
    • Multiple sources of the impedance cardiogram based on 3-D finite difference human thorax models
    • Wang L and Patterson R 1995 Multiple sources of the impedance cardiogram based on 3-D finite difference human thorax models IEEE Trans. Biomed. Eng. 42 141-8
    • (1995) IEEE Trans. Biomed. Eng. , vol.42 , Issue.2 , pp. 141-148
    • Wang, L.1    Patterson, R.2
  • 10
    • 0023526306 scopus 로고
    • Comparing reconstruction algorithms for electrical impedance tomography
    • Yorkey T J, Webster J G and Tompkins W J 1987 Comparing reconstruction algorithms for electrical impedance tomography IEEE Trans. Biomed. Eng. 34 843-52
    • (1987) IEEE Trans. Biomed. Eng. , vol.34 , pp. 843-852
    • Yorkey, T.J.1    Webster, J.G.2    Tompkins, W.J.3