메뉴 건너뛰기




Volumn 70, Issue 8, 1999, Pages 780-789

The non-invasive assessment of stroke volume and cardiac output by impedance cardiography: A review

Author keywords

Cardiac output; Cardiography; Cardiovascular; Impedance; Non invasive; Plethysmography; Stroke volume

Indexed keywords

ACCURACY; FUNCTIONAL ASSESSMENT; HEART OUTPUT; HEART STROKE VOLUME; HUMAN; IMPEDANCE CARDIOGRAPHY; MATHEMATICAL ANALYSIS; PLETHYSMOGRAPHY; RELIABILITY; REVIEW;

EID: 0032765191     PISSN: 00956562     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (88)

References (82)
  • 1
    • 0022980897 scopus 로고
    • A new stroke volume equation for thoracic bioimpedance: Theory and rationale
    • Bernstein DP. A new stroke volume equation for thoracic bioimpedance: theory and rationale. Crit Care Med 1986; 14:904-9.
    • (1986) Crit Care Med , vol.14 , pp. 904-909
    • Bernstein, D.P.1
  • 2
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1:307-10.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 3
    • 0026001662 scopus 로고
    • Cardiac output measurement in critical care patients: Thoracic electrical bioimpedance versus thermodilution
    • Clancy TV, Norman K, Reynolds R, et al. Cardiac output measurement in critical care patients: thoracic electrical bioimpedance versus thermodilution. J Trauma 1991; 31:1116-21.
    • (1991) J Trauma , vol.31 , pp. 1116-1121
    • Clancy, T.V.1    Norman, K.2    Reynolds, R.3
  • 4
    • 0025579162 scopus 로고
    • Clinical assessment of cardiac output
    • Conway J. Clinical assessment of cardiac output. Eur Heart J 1990; 11(Suppl 1):148-50.
    • (1990) Eur Heart J , vol.11 , Issue.SUPPL. 1 , pp. 148-150
    • Conway, J.1
  • 5
    • 0023864184 scopus 로고
    • Noninvasive assessment of cardiac performance by impedance cardiography: Disagreement between two equations to estimate stroke volume
    • De Mey C, Enterling D. Noninvasive assessment of cardiac performance by impedance cardiography: disagreement between two equations to estimate stroke volume. Aviat Space Environ Med 1988; 59:57-62.
    • (1988) Aviat Space Environ Med , vol.59 , pp. 57-62
    • De Mey, C.1    Enterling, D.2
  • 6
    • 0025495626 scopus 로고
    • Impedance plethysmography of thoracic region: Impedance cardiography
    • Deshpande AK, Jindal GD, Jagasia PM, et al. Impedance plethysmography of thoracic region: impedance cardiography. J Post-grad Med 1990; 36(4):207-12.
    • (1990) J Post-grad Med , vol.36 , Issue.4 , pp. 207-212
    • Deshpande, A.K.1    Jindal, G.D.2    Jagasia, P.M.3
  • 7
    • 0019796990 scopus 로고
    • Influence of respiration on stroke volume determined by impedance cardiography
    • Doerr BM, Miles DS, Frey MAB. Influence of respiration on stroke volume determined by impedance cardiography. Aviat Space Environ Med 1981; 52:394-8.
    • (1981) Aviat Space Environ Med , vol.52 , pp. 394-398
    • Doerr, B.M.1    Miles, D.S.2    Frey, M.A.B.3
  • 8
    • 0022653845 scopus 로고
    • The use of thoracic impedance for determining thoracic blood volume changes in man
    • Ebert TJ, Smith JJ, Barney JA, et al. The use of thoracic impedance for determining thoracic blood volume changes in man. Aviat Space Environ Med 1986; 57:49-53.
    • (1986) Aviat Space Environ Med , vol.57 , pp. 49-53
    • Ebert, T.J.1    Smith, J.J.2    Barney, J.A.3
  • 9
    • 0025256968 scopus 로고
    • Clinical evaluation of an ensemble-averaging impedance cardiograph for monitoring stroke volume during spontaneous breathing
    • Ekman LG, Milsom I, Arvidsson S, et al. Clinical evaluation of an ensemble-averaging impedance cardiograph for monitoring stroke volume during spontaneous breathing. Acta Anaesthesiol Scand 1990; 34:190-6.
    • (1990) Acta Anaesthesiol Scand , vol.34 , pp. 190-196
    • Ekman, L.G.1    Milsom, I.2    Arvidsson, S.3
  • 10
    • 0023503164 scopus 로고
    • Aerobic fitness in women and responses to lower body negative pressure
    • Frey MAB, Mathes KL, Hoffler GW. Aerobic fitness in women and responses to lower body negative pressure. Aviat Space Environ Med 1987; 58:1149-52.
    • (1987) Aviat Space Environ Med , vol.58 , pp. 1149-1152
    • Frey, M.A.B.1    Mathes, K.L.2    Hoffler, G.W.3
  • 11
    • 0026639782 scopus 로고
    • The validity of cardiac output measurement by thoracic impedance: A meta-analysis
    • Fuller HD. The validity of cardiac output measurement by thoracic impedance: a meta-analysis. Clin Invest Med 1992; 15(2): 103-12.
    • (1992) Clin Invest Med , vol.15 , Issue.2 , pp. 103-112
    • Fuller, H.D.1
  • 12
    • 0028087307 scopus 로고
    • Evaluation of left ventricular function by impedance cardiography: A review
    • Fuller HD. Evaluation of left ventricular function by impedance cardiography: a review. Prog Cardiovasc Dis 1994; 36(4):267-73.
    • (1994) Prog Cardiovasc Dis , vol.36 , Issue.4 , pp. 267-273
    • Fuller, H.D.1
  • 14
    • 0027180079 scopus 로고
    • Use of impedance cardiography for assessing cardiovascular control in humans: Orthostatic and valsalva tests
    • Gotshall RW, Miles DS. Use of impedance cardiography for assessing cardiovascular control in humans: orthostatic and valsalva tests. Biol Psychol 1993; 36:107-17.
    • (1993) Biol Psychol , vol.36 , pp. 107-117
    • Gotshall, R.W.1    Miles, D.S.2
  • 15
    • 0024323057 scopus 로고
    • Comparison of two impedance cardiographic techniques for measuring cardiac output in critically ill patients
    • Gotshall RW, Wood VC, Miles DS. Comparison of two impedance cardiographic techniques for measuring cardiac output in critically ill patients. Crit Care Med 1989; 17(8):806-11.
    • (1989) Crit Care Med , vol.17 , Issue.8 , pp. 806-811
    • Gotshall, R.W.1    Wood, V.C.2    Miles, D.S.3
  • 16
    • 0014263712 scopus 로고
    • Determination of cardiac output in man by means of impedance plethysmography
    • Harley A, Greenfield JC. Determination of cardiac output in man by means of impedance plethysmography. Aerosp Med 1968; 39:248-52.
    • (1968) Aerosp Med , vol.39 , pp. 248-252
    • Harley, A.1    Greenfield, J.C.2
  • 17
    • 0027139153 scopus 로고
    • Computer supported analysis of cardiovascular parameters by impedance cardiography and plethysmography
    • Hunold S, Hexamer M, Werner J, Gehrt M. Computer supported analysis of cardiovascular parameters by impedance cardiography and plethysmography. Med Prog Tech 1993; 19:105-13.
    • (1993) Med Prog Tech , vol.19 , pp. 105-113
    • Hunold, S.1    Hexamer, M.2    Werner, J.3    Gehrt, M.4
  • 18
    • 0027283023 scopus 로고
    • Issues in methodology and application of impedance cardiography: An introduction
    • Hurwitz BE. Issues in methodology and application of impedance cardiography: an introduction. Biol Psychol 1993; 36:1-2.
    • (1993) Biol Psychol , vol.36 , pp. 1-2
    • Hurwitz, B.E.1
  • 19
    • 0026409914 scopus 로고
    • Non-invasive measurement of cardiac output by thoracic electrical bioimpedance: A study of reproducibility and comparison with thermodilution
    • Jewkes C, Sear JW, Verhoeff F, et al. Non-invasive measurement of cardiac output by thoracic electrical bioimpedance: a study of reproducibility and comparison with thermodilution. Br J Anaesth 1991; 67:788-94.
    • (1991) Br J Anaesth , vol.67 , pp. 788-794
    • Jewkes, C.1    Sear, J.W.2    Verhoeff, F.3
  • 20
    • 0014515541 scopus 로고
    • Comparative evaluation of the thoracic impedance and isotope dilution methods for measuring cardiac output
    • Judy WV, Langley FM, McCowen KD, et al. Comparative evaluation of the thoracic impedance and isotope dilution methods for measuring cardiac output. Aerosp Med 1969; 40:532-6.
    • (1969) Aerosp Med , vol.40 , pp. 532-536
    • Judy, W.V.1    Langley, F.M.2    McCowen, K.D.3
  • 21
    • 0346446264 scopus 로고
    • Impedance cardiography for determination of stroke index
    • Keim HJ, Wallace JM, Thruston H, et al. Impedance cardiography for determination of stroke index. J Appl Physiol 1976; 41: 797-9.
    • (1976) J Appl Physiol , vol.41 , pp. 797-799
    • Keim, H.J.1    Wallace, J.M.2    Thruston, H.3
  • 22
    • 0026679307 scopus 로고
    • A new ensemble averaging technique in impedance cardiography for estimation of stroke volume during treadmill exercise
    • Kim DK, Song CG, Lee MH. A new ensemble averaging technique in impedance cardiography for estimation of stroke volume during treadmill exercise. Frontiers Med Biol Engng 1992; 4(3): 179-88.
    • (1992) Frontiers Med Biol Engng , vol.4 , Issue.3 , pp. 179-188
    • Kim, D.K.1    Song, C.G.2    Lee, M.H.3
  • 23
    • 0013978742 scopus 로고
    • Development and evaluation of an impedance cardiac output system
    • Kubicek WG, Karnegis JN, Patterson RP, et al. Development and evaluation of an impedance cardiac output system. Aerosp Med 1966; 37:1208-12.
    • (1966) Aerosp Med , vol.37 , pp. 1208-1212
    • Kubicek, W.G.1    Karnegis, J.N.2    Patterson, R.P.3
  • 24
    • 0016100772 scopus 로고
    • The Minnesota impedance cardiograph-theory and applications
    • Kubicek WG, Kottke FJ, Ramos MU, et al. The Minnesota impedance cardiograph-theory and applications. Biomed Eng 1974; 9:410-6.
    • (1974) Biomed Eng , vol.9 , pp. 410-416
    • Kubicek, W.G.1    Kottke, F.J.2    Ramos, M.U.3
  • 25
    • 0024430214 scopus 로고
    • On the source of peak first time derivative (dZ/dt) during impedance cardiography
    • Kubicek WG. On the source of peak first time derivative (dZ/dt) during impedance cardiography. Ann Biomed Eng 1989; 17: 459-62.
    • (1989) Ann Biomed Eng , vol.17 , pp. 459-462
    • Kubicek, W.G.1
  • 26
    • 84981642933 scopus 로고
    • Impedance cardiography as a non-invasive method of monitoring cardiac function and other parameters of the cardiovascular system
    • Kubicek WG, Patterson RP, Witsoe DA. Impedance cardiography as a non-invasive method of monitoring cardiac function and other parameters of the cardiovascular system. Ann NY Acad Sci 1970; 170:724-32.
    • (1970) Ann NY Acad Sci , vol.170 , pp. 724-732
    • Kubicek, W.G.1    Patterson, R.P.2    Witsoe, D.A.3
  • 29
    • 0020972273 scopus 로고
    • Cardiac function monitored by impedance cardiography during changing seatback angles and anti-G suit inflation
    • Logan JS, Veghte JH, Frey MAB, et al. Cardiac function monitored by impedance cardiography during changing seatback angles and anti-G suit inflation. Aviat Space Environ Med 1983; 54: 328-33.
    • (1983) Aviat Space Environ Med , vol.54 , pp. 328-333
    • Logan, J.S.1    Veghte, J.H.2    Frey, M.A.B.3
  • 30
    • 0027246664 scopus 로고
    • Impedance cardiography used to assess patterns of cardiovascular response to behavioural stressors
    • Lovallo WR, Pincomb GA, Sung BH, Wilson MF. Impedance cardiography used to assess patterns of cardiovascular response to behavioural Stressors. Biol Psychol 1993; 36:97-105.
    • (1993) Biol Psychol , vol.36 , pp. 97-105
    • Lovallo, W.R.1    Pincomb, G.A.2    Sung, B.H.3    Wilson, M.F.4
  • 31
    • 0025834464 scopus 로고
    • Blood volume distribution during head-up tilt induced central hypovolaemia in man
    • Matzen S, Perko G, Groth S, et al. Blood volume distribution during head-up tilt induced central hypovolaemia in man. Clin Physiol 1991; 11:411-22.
    • (1991) Clin Physiol , vol.11 , pp. 411-422
    • Matzen, S.1    Perko, G.2    Groth, S.3
  • 32
    • 0025990644 scopus 로고
    • Reliability of impedance cardiography in measuring central haemodynamics
    • Mehlsen J, Bonde J, Stadeager C, et al. Reliability of impedance cardiography in measuring central haemodynamics. Clin Physiol 1991; 11:579-88.
    • (1991) Clin Physiol , vol.11 , pp. 579-588
    • Mehlsen, J.1    Bonde, J.2    Stadeager, C.3
  • 33
    • 0024329710 scopus 로고
    • Impedance cardiography: Non-invasive assessment of human central hemodynamics at rest and during exercise
    • Pandolf KB, ed. Sydney: Williams and Wilkins
    • Miles DS, Gotshall RW. Impedance cardiography: non-invasive assessment of human central hemodynamics at rest and during exercise. In: Pandolf KB, ed. Exercise and sport science reviews, vol. 17. Sydney: Williams and Wilkins, 1989.
    • (1989) Exercise and Sport Science Reviews , vol.17
    • Miles, D.S.1    Gotshall, R.W.2
  • 34
    • 0023820483 scopus 로고
    • Single-breath DLco maneuver causes cardiac output to fall during and after cycling
    • Miles DS, Gotshall RW, Motta MR, Duncan CA. Single-breath DLco maneuver causes cardiac output to fall during and after cycling. J Appl Physiol 1988; 65:41-5.
    • (1988) J Appl Physiol , vol.65 , pp. 41-45
    • Miles, D.S.1    Gotshall, R.W.2    Motta, M.R.3    Duncan, C.A.4
  • 35
    • 0021232250 scopus 로고
    • Central haemodynamics during progressive upper- and lower-body exercise and recovery
    • Miles DS, Sawka MN, Hanpeter DE, et al. Central haemodynamics during progressive upper- and lower-body exercise and recovery. J Appl Physiol 1984; 57:366-70.
    • (1984) J Appl Physiol , vol.57 , pp. 366-370
    • Miles, D.S.1    Sawka, M.N.2    Hanpeter, D.E.3
  • 36
    • 0019820654 scopus 로고
    • Estimation of cardiac output by electrical impedance during arm exercise in women
    • Miles DS, Sawka MN, Wilde SW, et al. Estimation of cardiac output by electrical impedance during arm exercise in women. J Appl Physiol 1981; 51:1488-92.
    • (1981) J Appl Physiol , vol.51 , pp. 1488-1492
    • Miles, D.S.1    Sawka, M.N.2    Wilde, S.W.3
  • 37
    • 0022530871 scopus 로고
    • Evaluation of impedance cardiography in the canine pup
    • Miles DS, Gotshall RW, Sexson WR. Evaluation of impedance cardiography in the canine pup. J Appl Physiol 1986; 60:260-5.
    • (1986) J Appl Physiol , vol.60 , pp. 260-265
    • Miles, D.S.1    Gotshall, R.W.2    Sexson, W.R.3
  • 38
    • 0030867039 scopus 로고    scopus 로고
    • Sympatho-vagal responses in humans to thermoneutral head-out water immersion
    • Miwa C, Sugiyama Y, Mano T, et al. Sympatho-vagal responses in humans to thermoneutral head-out water immersion. Aviat Space Environ Med 1997; 68:1109-14.
    • (1997) Aviat Space Environ Med , vol.68 , pp. 1109-1114
    • Miwa, C.1    Sugiyama, Y.2    Mano, T.3
  • 39
    • 0021087487 scopus 로고
    • Dynamics of cardiac output and systolic time intervals in supine and upright exercise
    • Miyamoto Y, Higuchi J, Abe Y, et al. Dynamics of cardiac output and systolic time intervals in supine and upright exercise. J Appl Physiol 1983; 55(6):1674-81.
    • (1983) J Appl Physiol , vol.55 , Issue.6 , pp. 1674-1681
    • Miyamoto, Y.1    Higuchi, J.2    Abe, Y.3
  • 41
    • 0027444956 scopus 로고
    • Body volume changes during simulated micro-gravity I: Technique and comparison of men and women during horizontal bed rest
    • Montgomery LD. Body volume changes during simulated micro-gravity I: technique and comparison of men and women during horizontal bed rest. Aviat Space Environ Med 1993; 64: 893-8.
    • (1993) Aviat Space Environ Med , vol.64 , pp. 893-898
    • Montgomery, L.D.1
  • 42
    • 0021804021 scopus 로고
    • Determination of cardiac output using ensemble-averaged impedance cardiograms
    • Muzi M, Ebert TJ, Tristani FE, et al. Determination of cardiac output using ensemble-averaged impedance cardiograms. J Appl Physiol 1985; 58:200-5.
    • (1985) J Appl Physiol , vol.58 , pp. 200-205
    • Muzi, M.1    Ebert, T.J.2    Tristani, F.E.3
  • 43
    • 0031922863 scopus 로고    scopus 로고
    • Evidence of baroreflex adaptation to repetitive +Gz in fighter pilots
    • Newman DG, White SW, Callister R. Evidence of baroreflex adaptation to repetitive +Gz in fighter pilots. Aviat Space Environ Med 1998; 69:446-51.
    • (1998) Aviat Space Environ Med , vol.69 , pp. 446-451
    • Newman, D.G.1    White, S.W.2    Callister, R.3
  • 45
    • 0025124559 scopus 로고
    • Non-invasive determination of cardiac output by doppler echocardiography and electrical bioimpedance
    • Northridge DB, Findlay IN, Wilson J, et al. Non-invasive determination of cardiac output by Doppler echocardiography and electrical bioimpedance. Br Heart J 1990; 63:93-7.
    • (1990) Br Heart J , vol.63 , pp. 93-97
    • Northridge, D.B.1    Findlay, I.N.2    Wilson, J.3
  • 46
    • 0025859813 scopus 로고
    • Improving agreement between thoracic bioimpedance and dye dilution cardiac output estimation in children
    • O'Connell AJ, Tibballs J, Coulthard M. Improving agreement between thoracic bioimpedance and dye dilution cardiac output estimation in children. Anaesth Int Care 1991; 19:434-40.
    • (1991) Anaesth Int Care , vol.19 , pp. 434-440
    • O'Connell, A.J.1    Tibballs, J.2    Coulthard, M.3
  • 47
    • 0025081046 scopus 로고
    • Cardiac responses to the Valsalva manoeuvre in different body positions
    • Olschewski H, Bruck K. Cardiac responses to the Valsalva manoeuvre in different body positions. Eur J Appl Physiol 1990; 61:20-5.
    • (1990) Eur J Appl Physiol , vol.61 , pp. 20-25
    • Olschewski, H.1    Bruck, K.2
  • 48
    • 0027293475 scopus 로고
    • Variability of cardiac output as determined by impedance cardiography in pacemaker patients
    • Ovsyshcher I, Gross JN, Blumberg S, et al. Variability of cardiac output as determined by impedance cardiography in pacemaker patients. Am J Cardiol 1993; 72:183-7.
    • (1993) Am J Cardiol , vol.72 , pp. 183-187
    • Ovsyshcher, I.1    Gross, J.N.2    Blumberg, S.3
  • 50
    • 0027222010 scopus 로고
    • Impedance cardiography: The failure of sternal electrodes to predict changes in stroke volume
    • Patterson RP, Wang L, McVeigh G, et al. Impedance cardiography: the failure of sternal electrodes to predict changes in stroke volume. Biol Psychol 1993; 36:33-41.
    • (1993) Biol Psychol , vol.36 , pp. 33-41
    • Patterson, R.P.1    Wang, L.2    McVeigh, G.3
  • 51
    • 0025428774 scopus 로고
    • Mapping the cardiogenic impedance signal on the thoracic surface
    • Patterson RP, Wang L, Raza B, Wood K. Mapping the cardiogenic impedance signal on the thoracic surface. Med Biol Eng Comput 1990; 28:212-6.
    • (1990) Med Biol Eng Comput , vol.28 , pp. 212-216
    • Patterson, R.P.1    Wang, L.2    Raza, B.3    Wood, K.4
  • 52
    • 0024991534 scopus 로고
    • Validation of impedance cardiography measurements of cardiac output during limited exercise in heart transplant recipients
    • Pepke-Zaba J, Higenbottam TW, Dinh Xuan AT, et al. Validation of impedance cardiography measurements of cardiac output during limited exercise in heart transplant recipients. Transplant Int 1990; 3:108-12.
    • (1990) Transplant Int , vol.3 , pp. 108-112
    • Pepke-Zaba, J.1    Higenbottam, T.W.2    Dinh Xuan, A.T.3
  • 53
    • 0027285427 scopus 로고
    • Usefulness of the impedance cardiogram to reflect left ventricular diastolic function
    • Pickett BR, Buell JC. Usefulness of the impedance cardiogram to reflect left ventricular diastolic function. Am J Cardiol 1993; 71:1099-103.
    • (1993) Am J Cardiol , vol.71 , pp. 1099-1103
    • Pickett, B.R.1    Buell, J.C.2
  • 54
    • 0026651625 scopus 로고
    • Validity of cardiac output measurement by computer-averaged impedance cardiography, and comparison with simultaneous thermodilution determinations
    • Pickett BR, Buell JC. Validity of cardiac output measurement by computer-averaged impedance cardiography, and comparison with simultaneous thermodilution determinations. Am J Cardiol 1992; 69:1354-8.
    • (1992) Am J Cardiol , vol.69 , pp. 1354-1358
    • Pickett, B.R.1    Buell, J.C.2
  • 55
    • 0024364123 scopus 로고
    • Transthoracic electrical bioimpedance versus thermodilution technique for cardiac output measurement during mechanical ventilation
    • Preiser JC, Daper A, Parquier JN, et al. Transthoracic electrical bioimpedance versus thermodilution technique for cardiac output measurement during mechanical ventilation. Intensive Care Med 1989; 15:221-3.
    • (1989) Intensive Care Med , vol.15 , pp. 221-223
    • Preiser, J.C.1    Daper, A.2    Parquier, J.N.3
  • 56
    • 0019349890 scopus 로고
    • Thoracic resistivity for stroke volume calculation in impedance cardiography
    • Quail AW, Traugott FM, Porges WL, White SW. Thoracic resistivity for stroke volume calculation in impedance cardiography. J Appl Physiol 1981; 50:191-5.
    • (1981) J Appl Physiol , vol.50 , pp. 191-195
    • Quail, A.W.1    Traugott, F.M.2    Porges, W.L.3    White, S.W.4
  • 57
    • 0027410339 scopus 로고
    • Continuous cardiac output: Myth or reality?
    • Ramsay JG. Continuous cardiac output: myth or reality? Can J Anaesth 1993; 40:98-102.
    • (1993) Can J Anaesth , vol.40 , pp. 98-102
    • Ramsay, J.G.1
  • 58
    • 0026761081 scopus 로고
    • Filtering respiration and low-frequency movement artefacts from the cardiogenic electrical impedance signal
    • Raza SB, Patterson RP, Wang L. Filtering respiration and low-frequency movement artefacts from the cardiogenic electrical impedance signal. Med Biol Eng Comput 1992; 30:556-61.
    • (1992) Med Biol Eng Comput , vol.30 , pp. 556-561
    • Raza, S.B.1    Patterson, R.P.2    Wang, L.3
  • 59
    • 0023787022 scopus 로고
    • Comparison of cardiac output estimation by thoracic electrical bioimpedance, thermodilution, and pick methods
    • Salandin V, Zussa C, Risica G, et al. Comparison of cardiac output estimation by thoracic electrical bioimpedance, thermodilution, and Pick methods. Crit Care Med 1988; 16:1157-8.
    • (1988) Crit Care Med , vol.16 , pp. 1157-1158
    • Salandin, V.1    Zussa, C.2    Risica, G.3
  • 60
    • 0026457202 scopus 로고
    • Improvement in intracardiac impedance volumes by field extrapolation
    • Salo RW. Improvement in intracardiac impedance volumes by field extrapolation. Eur Heart J 1992; 13(Suppl. E):35-9.
    • (1992) Eur Heart J , vol.13 , Issue.SUPPL. E , pp. 35-39
    • Salo, R.W.1
  • 61
    • 0027406788 scopus 로고
    • New investigations of autonomic nervous system function
    • Schondorf R. New investigations of autonomic nervous system function. J Clin Neurophysiol 1993; 10:28-38.
    • (1993) J Clin Neurophysiol , vol.10 , pp. 28-38
    • Schondorf, R.1
  • 62
    • 0345029775 scopus 로고
    • Gender specific cardiovascular response: Contribution of β-adrenergic mechanism
    • Schondorf R, Low PA. Gender specific cardiovascular response: contribution of β-adrenergic mechanism. Neurology 1992; 42(Suppl 3):137.
    • (1992) Neurology , vol.42 , Issue.SUPPL. 3 , pp. 137
    • Schondorf, R.1    Low, P.A.2
  • 63
    • 0025973109 scopus 로고
    • Cardiac output by impedance cardiography: Two alternative methodologies compared with thermodilution
    • Sherwood A, Carter LS, Murphy CA. Cardiac output by impedance cardiography: two alternative methodologies compared with thermodilution. Aviat Space Environ Med 1991; 62:116-22.
    • (1991) Aviat Space Environ Med , vol.62 , pp. 116-122
    • Sherwood, A.1    Carter, L.S.2    Murphy, C.A.3
  • 64
    • 0025510365 scopus 로고
    • Non-invasive determination of cardiac output by doppler echocardiography and electrical bioimpedance
    • Shoemaker WC. Non-invasive determination of cardiac output by Doppler echocardiography and electrical bioimpedance. Br Heart J 1990; 64:347.
    • (1990) Br Heart J , vol.64 , pp. 347
    • Shoemaker, W.C.1
  • 66
    • 0023931663 scopus 로고
    • Automated non-invasive measurement of cardiac output: Comparison of electrical bioimpedance and carbon dioxide rebreathing techniques
    • Smith SA, Russell AE, West MJ, Chalmers J. Automated non-invasive measurement of cardiac output: comparison of electrical bioimpedance and carbon dioxide rebreathing techniques. Br Heart J 1988; 59:292-8.
    • (1988) Br Heart J , vol.59 , pp. 292-298
    • Smith, S.A.1    Russell, A.E.2    West, M.J.3    Chalmers, J.4
  • 67
    • 0025166460 scopus 로고
    • Noninvasive versus invasive assessment of cardiac output after cardiac surgery: Clinical validation
    • Spahn DR, Schmid ER, Tornic M, et al. Noninvasive versus invasive assessment of cardiac output after cardiac surgery: clinical validation. J Cardiothorac Anesth 1990; 4(1):46-59.
    • (1990) J Cardiothorac Anesth , vol.4 , Issue.1 , pp. 46-59
    • Spahn, D.R.1    Schmid, E.R.2    Tornic, M.3
  • 68
    • 0023894669 scopus 로고
    • Comparison of bioimpedance and thermodilution methods for determining cardiac output: Experimental and clinical studies
    • Spinale FG, Reines HD, Crawford FA. Comparison of bioimpedance and thermodilution methods for determining cardiac output: experimental and clinical studies. Ann Thorac Surg 1988; 45:421-5.
    • (1988) Ann Thorac Surg , vol.45 , pp. 421-425
    • Spinale, F.G.1    Reines, H.D.2    Crawford, F.A.3
  • 69
    • 0025194984 scopus 로고
    • Relationship of bioimpedance to thermodilution and echocardiographic measurements of cardiac function
    • Spinale FG, Smith AC, Crawford FA. Relationship of bioimpedance to thermodilution and echocardiographic measurements of cardiac function. Crit Care Med 1990; 18:414-8.
    • (1990) Crit Care Med , vol.18 , pp. 414-418
    • Spinale, F.G.1    Smith, A.C.2    Crawford, F.A.3
  • 70
    • 85047677418 scopus 로고
    • Relationship between bioimpedance, thermodilution, and ventriculographic measurements in experimental congestive heart failure
    • Spinale FG, Hendrick DA, Crawford FA, Carabello BA. Relationship between bioimpedance, thermodilution, and ventriculographic measurements in experimental congestive heart failure. Cardiovasc Res 1990; 24:423-9.
    • (1990) Cardiovasc Res , vol.24 , pp. 423-429
    • Spinale, F.G.1    Hendrick, D.A.2    Crawford, F.A.3    Carabello, B.A.4
  • 71
    • 0026877312 scopus 로고
    • Noninvasive evaluation of cardiac index and ejection fraction in ischaemic cardiopathy. Comparison of thoracic bioimpedance, thermodilution and cineventriculography
    • Talarico G, Saino A, Lotto A. Noninvasive evaluation of cardiac index and ejection fraction in ischaemic cardiopathy. Comparison of thoracic bioimpedance, thermodilution and cineventriculography. Minerva Cardioangiol 1992; 40:203-9.
    • (1992) Minerva Cardioangiol , vol.40 , pp. 203-209
    • Talarico, G.1    Saino, A.2    Lotto, A.3
  • 72
    • 0025786660 scopus 로고
    • Bioimpedance versus thermodilution cardiac output measurement: The bomed NCCOM-3 after coronary bypass surgery
    • Thomas AN, Ryan J, Doran BRH, Pollard BJ. Bioimpedance versus thermodilution cardiac output measurement: the Bomed NCCOM-3 after coronary bypass surgery, Intensive Care Med 1991; 17:383-6.
    • (1991) Intensive Care Med , vol.17 , pp. 383-386
    • Thomas, A.N.1    Ryan, J.2    Doran, B.R.H.3    Pollard, B.J.4
  • 73
    • 0027480746 scopus 로고
    • Impedance cardiography during exercise in patients with coronary heart disease
    • Thomas SHL, Crowther A. Impedance cardiography during exercise in patients with coronary heart disease. Eur Heart J 1993; 14:150-9.
    • (1993) Eur Heart J , vol.14 , pp. 150-159
    • Thomas, S.H.L.1    Crowther, A.2
  • 74
    • 0024318871 scopus 로고
    • Transthoracic electrical bioimpedance versus thermodilution technique for cardiac output measurement during mechanical ventilation
    • Tremper K. Transthoracic electrical bioimpedance versus thermodilution technique for cardiac output measurement during mechanical ventilation. Intensive Care Med 1989; 15:219-20.
    • (1989) Intensive Care Med , vol.15 , pp. 219-220
    • Tremper, K.1
  • 75
    • 0018423668 scopus 로고
    • Stroke volume and systolic time interval adjustments during bicycle exercise
    • Vanfraechem JHP. Stroke volume and systolic time interval adjustments during bicycle exercise. J Appl Physiol 1979; 46(3): 588-92.
    • (1979) J Appl Physiol , vol.46 , Issue.3 , pp. 588-592
    • Vanfraechem, J.H.P.1
  • 76
    • 85047680118 scopus 로고
    • Investigation of the origin of the impedance cardiogram by means of exchange transfusion with stroma free haemoglobin solution in the dog
    • Visser KR, Lamberts R, Zijlstra WG. Investigation of the origin of the impedance cardiogram by means of exchange transfusion with stroma free haemoglobin solution in the dog. Cardiovasc Res 1990; 24:24-32.
    • (1990) Cardiovasc Res , vol.24 , pp. 24-32
    • Visser, K.R.1    Lamberts, R.2    Zijlstra, W.G.3
  • 77
    • 0027443446 scopus 로고
    • Registration of thoracic electrical bioimpedance for early diagnosis of rejection after heart transplantation
    • Weinhold C, Reichenspurner H, Fulle P, et al. Registration of thoracic electrical bioimpedance for early diagnosis of rejection after heart transplantation. J Heart Lung Transplant 1993; 12: 832-6.
    • (1993) J Heart Lung Transplant , vol.12 , pp. 832-836
    • Weinhold, C.1    Reichenspurner, H.2    Fulle, P.3
  • 78
    • 0026878489 scopus 로고
    • Do changes in transcardiac impedance modulation correlate with haemodynamic status?
    • Weiss SM, Einstein R, Matthews RJ, et al. Do changes in transcardiac impedance modulation correlate with haemodynamic status? Aust Phys Eng Sci Med 1992; 15(2):57-64.
    • (1992) Aust Phys Eng Sci Med , vol.15 , Issue.2 , pp. 57-64
    • Weiss, S.M.1    Einstein, R.2    Matthews, R.J.3
  • 79
    • 0344598851 scopus 로고
    • Accuracy of continuous non-invasive impedance cardiographic measurements of stroke volume in exercising man
    • Howell MC, Parker AW, eds. Queensland: University of Queensland
    • White SW, Letchford PJ, Traugott FM, et al. Accuracy of continuous non-invasive impedance cardiographic measurements of stroke volume in exercising man. In: Howell MC, Parker AW, eds. Sports medicine: medical and scientific aspects of elitism in sport, vol. 8. Queensland: University of Queensland, 1984.
    • (1984) Sports Medicine: Medical and Scientific Aspects of Elitism in Sport , vol.8
    • White, S.W.1    Letchford, P.J.2    Traugott, F.M.3
  • 80
    • 0025611934 scopus 로고
    • Impedance cardiography for cardiac output measurement: An evaluation of accuracy and limitations
    • White SW, Quail AW, DeLeeuw PW, et al. Impedance cardiography for cardiac output measurement: an evaluation of accuracy and limitations. Eur Heart J 1990; 11(Supp 1):79-92.
    • (1990) Eur Heart J , vol.11 , Issue.SUPPL. 1 , pp. 79-92
    • White, S.W.1    Quail, A.W.2    Deleeuw, P.W.3
  • 81
    • 0025361628 scopus 로고
    • Non-invasive cardiac output: Simultaneous comparison of two different methods with thermodilution
    • Wong DH, Tremper KK, Stemmer EA, et al. Non-invasive cardiac output: simultaneous comparison of two different methods with thermodilution. Anaesthesiology 1990; 72:784-92.
    • (1990) Anaesthesiology , vol.72 , pp. 784-792
    • Wong, D.H.1    Tremper, K.K.2    Stemmer, E.A.3
  • 82
    • 0026395116 scopus 로고
    • Comparison of thermodilution and transthoracic electrical bioimpedance cardiac outputs
    • Woo MA, Hamilton M, Stevenson LW, Vredevoe DL. Comparison of thermodilution and transthoracic electrical bioimpedance cardiac outputs. Heart Lung 1991; 20:357-62.
    • (1991) Heart Lung , vol.20 , pp. 357-362
    • Woo, M.A.1    Hamilton, M.2    Stevenson, L.W.3    Vredevoe, D.L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.