메뉴 건너뛰기




Volumn 6144 II, Issue , 2006, Pages

Physics-based constraints for correction of geometric distortions in gradient echo EP images via nonrigid registration

Author keywords

Geometric distortion correction; Gradient Echo EPI; Intravoxel dephasing; Nonrigid registration

Indexed keywords

ALGORITHMS; DEFORMATION; GEOMETRY; MAGNETIC RESONANCE IMAGING; ULTRASONIC IMAGING;

EID: 33745132728     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.652260     Document Type: Conference Paper
Times cited : (8)

References (29)
  • 1
    • 0032883422 scopus 로고    scopus 로고
    • Sources of distortion in functional MRI data
    • Peter Jezzard and Stuart Clare, Sources of distortion in functional MRI data, Hum Brain Mapp. 1999;8(2-3):80-5
    • (1999) Hum Brain Mapp. , vol.8 , Issue.2-3 , pp. 80-85
    • Jezzard, P.1    Clare, S.2
  • 2
    • 13444269148 scopus 로고    scopus 로고
    • Computer simulation studies of the effects of dynamic shimming on susceptibility artifacts in EPI at high field
    • Mar
    • Zhao Y, Anderson AW, Gore JC, Computer simulation studies of the effects of dynamic shimming on susceptibility artifacts in EPI at high field, J Magn Reson. 2005 Mar; 173(1): 10-22
    • (2005) J Magn Reson. , vol.173 , Issue.1 , pp. 10-22
    • Zhao, Y.1    Anderson, A.W.2    Gore, J.C.3
  • 3
    • 0032994289 scopus 로고    scopus 로고
    • Correction for EPI distortions using multi-echo gradient-echo imaging
    • Nan-kuei Chen, Alice M. Wyrwicz, Correction for EPI distortions using multi-echo gradient-echo imaging, Magn.Reson.Med. 1999;41:1206-1213
    • (1999) Magn. Reson. Med. , vol.41 , pp. 1206-1213
    • Chen, N.-K.1    Wyrwicz, A.M.2
  • 4
    • 0035101324 scopus 로고    scopus 로고
    • Optimized distortion correction technique for echo planar imaging
    • Nan-kuei Chen, Alice M. Wyrwicz, Optimized distortion correction technique for echo planar imaging. Magn.Reson.Med. 2001;45:525-528
    • (2001) Magn. Reson. Med. , vol.45 , pp. 525-528
    • Chen, N.-K.1    Wyrwicz, A.M.2
  • 7
    • 0029034190 scopus 로고
    • Correction for geometric distortion in echo-planar images from B-0 field variations
    • Jezzard P, Balaban RS: Correction for Geometric Distortion in Echo-Planar Images from B-0 Field Variations. Magn.Reson.Med. 1995;34:65-73
    • (1995) Magn. Reson. Med. , vol.34 , pp. 65-73
    • Jezzard, P.1    Balaban, R.S.2
  • 9
    • 0037225526 scopus 로고    scopus 로고
    • An evaluation of the use of magnetic field maps to undistort echo-planar images
    • Cusack R, Brett M, Osswald K: An evaluation of the use of magnetic field maps to undistort echo-planar images. NeuroImage 2003;18:127-142
    • (2003) NeuroImage , vol.18 , pp. 127-142
    • Cusack, R.1    Brett, M.2    Osswald, K.3
  • 12
    • 0034310510 scopus 로고    scopus 로고
    • Accurate alignment of functional EPI data to anatomical MRI using a physics-based distortion model
    • Nov
    • C. Studholme, R. T. Constable, and J. S. Duncan, Accurate Alignment of Functional EPI Data to Anatomical MRI Using a Physics-Based Distortion Model, IEEE Trans Med Imaging. 2000 Nov;19(11):1115-27
    • (2000) IEEE Trans Med Imaging , vol.19 , Issue.11 , pp. 1115-1127
    • Studholme, C.1    Constable, R.T.2    Duncan, J.S.3
  • 16
    • 27644550523 scopus 로고    scopus 로고
    • Geometric distortion correction of high-resolution 3 T diffusion tensor brain images
    • Nov
    • Ardekani S, Sinha U., Geometric distortion correction of high-resolution 3 T diffusion tensor brain images, Magn Reson Med. 2005 Nov;54(5):1163-71.
    • (2005) Magn Reson Med. , vol.54 , Issue.5 , pp. 1163-1171
    • Ardekani, S.1    Sinha, U.2
  • 17
    • 26844510712 scopus 로고    scopus 로고
    • Improving geometric accuracy in the presence of susceptibility difference artifacts produced by metallic implants in magnetic resonance imaging
    • Pauchard Y, Smith MR, Mintchev MP., Improving geometric accuracy in the presence of susceptibility difference artifacts produced by metallic implants in magnetic resonance imaging, IEEE Trans Med Imaging. 2005 Oct; 24(10): 1387-99.
    • (2005) IEEE Trans Med Imaging. , vol.24 , Issue.10 , pp. 1387-1399
    • Pauchard, Y.1    Smith, M.R.2    Mintchev, M.P.3
  • 19
    • 0037225733 scopus 로고    scopus 로고
    • Fast, automated, N-dimensional phase-unwrapping algorithm
    • Jan
    • Jenkinson M., Fast, automated, N-dimensional phase-unwrapping algorithm. Magn Reson Med. 2003 Jan; 49(1): 193-7.
    • (2003) Magn Reson Med. , vol.49 , Issue.1 , pp. 193-197
    • Jenkinson, M.1
  • 20
    • 0025016944 scopus 로고
    • Cause of signal loss in MR images of old hemorrhagic lesions
    • Feb
    • Hardy PA, Kucharczyk W, Henkelman RM, Cause of signal loss in MR images of old hemorrhagic lesions, Radiology. 1990 Feb;174(2):549-55
    • (1990) Radiology , vol.174 , Issue.2 , pp. 549-555
    • Hardy, P.A.1    Kucharczyk, W.2    Henkelman, R.M.3
  • 23
    • 33745146054 scopus 로고    scopus 로고
    • Correction of local image intensity dropout associated with intravoxel dephasing in gradient echo imaging using local field maps
    • N. Xu, J.M. Fitzpatrick, C. B. Paschal, H. Zeng, J.C.Gatenby, J. C. Gore, "Correction of Local Image Intensity Dropout Associated with Intravoxel Dephasing in Gradient Echo Imaging Using Local Field Maps", ISMRM 05.
    • ISMRM 05
    • Xu, N.1    Fitzpatrick, J.M.2    Paschal, C.B.3    Zeng, H.4    Gatenby, J.C.5    Gore, J.C.6
  • 24
    • 0344033872 scopus 로고    scopus 로고
    • The adaptive bases algorithm for intensity-based nonrigid image registration
    • GK Rohde, A. Aldroubi, and Benoit M. Dawant, The adaptive bases algorithm for intensity-based nonrigid image registration, TMI2003,22(11): 1470-1479.
    • (2003) TMI , vol.22 , Issue.11 , pp. 1470-1479
    • Rohde, G.K.1    Aldroubi, A.2    Dawant, B.M.3
  • 25
    • 0032762144 scopus 로고    scopus 로고
    • An overlap invariant entropy measure of 3D medical image alignment
    • Studholme C, Hill D L G and Hawkes D J, An overlap invariant entropy measure of 3D medical image alignment Pattern Recognition 32 (1999) 71-86
    • (1999) Pattern Recognition , vol.32 , pp. 71-86
    • Studholme, C.1    Hill, D.L.G.2    Hawkes, D.J.3
  • 27
    • 33745159899 scopus 로고    scopus 로고
    • http://www.fmrib.ox.ac.uk/fsl/
  • 28
    • 10044235365 scopus 로고    scopus 로고
    • Reduction of magnetic field inhomogeneity artifacts in echo planar imaging with SENSE and GESEPI at high field
    • Dec
    • Yang QX, Wang J, Smith MB, Meadowcroft M, Sun X, Eslinger PJ, Golay X, Reduction of magnetic field inhomogeneity artifacts in echo planar imaging with SENSE and GESEPI at high field, Magn Reson Med. 2004 Dec;52(6):1418-23.
    • (2004) Magn Reson Med. , vol.52 , Issue.6 , pp. 1418-1423
    • Yang, Q.X.1    Wang, J.2    Smith, M.B.3    Meadowcroft, M.4    Sun, X.5    Eslinger, P.J.6    Golay, X.7
  • 29
    • 0026925939 scopus 로고
    • A technique for accurate magnetic resonance imaging in the presence of field inhomogeneities
    • Sep
    • H. Chang and J. M. Fitzpatrick, "A technique for accurate magnetic resonance imaging in the presence of field inhomogeneities", IEEE Transactions on Medical Imaging 11, 319-329 (Sep 1992).
    • (1992) IEEE Transactions on Medical Imaging , vol.11 , pp. 319-329
    • Chang, H.1    Fitzpatrick, J.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.