메뉴 건너뛰기




Volumn 8, Issue 4, 2006, Pages 607-617

MR evaluation of cardiovascular physiology in congenital heart disease: Flow and function

Author keywords

Cine MRI; Congenital Heart Disease; Myocardial Tagging; Phase Contrast MRI; Review

Indexed keywords

AORTA COARCTATION; CARDIOVASCULAR FUNCTION; CONGENITAL HEART DISEASE; CORONARY ARTERY BLOOD FLOW; DIAGNOSTIC IMAGING; DIAGNOSTIC PROCEDURE; FUNCTIONAL ASSESSMENT; HEART ATRIUM SEPTUM DEFECT; HEART CYCLE; HEART LEFT RIGHT SHUNT; HEART MUSCLE; HEART SEPTUM DEFECT; HEART VALVE REGURGITATION; HEART VENTRICLE SEPTUM DEFECT; HUMAN; MORPHOLOGY; NUCLEAR MAGNETIC RESONANCE IMAGING; POSTOPERATIVE PERIOD; PREOPERATIVE EVALUATION; PRIORITY JOURNAL; PULMONARY ARTERY MALFORMATION; PULMONARY VALVE INSUFFICIENCY; REVIEW; VELOCITY;

EID: 33745131406     PISSN: 10976647     EISSN: 1532429X     Source Type: Journal    
DOI: 10.1080/10976640600740254     Document Type: Review
Times cited : (58)

References (27)
  • 1
    • 0033845492 scopus 로고    scopus 로고
    • Quantification of Left Ventricular Function with Magnetic Resonance Images Acquired in Real Time
    • Setser RM, Fischer SE, Lorenz CH. Quantification of Left Ventricular Function with Magnetic Resonance Images Acquired in Real Time. J Magn Reson Imaging 2000;12:430-438.
    • (2000) J Magn Reson Imaging , vol.12 , pp. 430-438
    • Setser, R.M.1    Fischer, S.E.2    Lorenz, C.H.3
  • 2
    • 0032873080 scopus 로고    scopus 로고
    • Novel real-time R-wave detection algorithm based on the vectorcardiogram for accurate gated magnetic resonance acquisitions
    • Fischer SE, Wickline, SA, Lorenz, CH. Novel real-time R-wave detection algorithm based on the vectorcardiogram for accurate gated magnetic resonance acquisitions. Magn Reson Med 1999;42:361-70.
    • (1999) Magn Reson Med , vol.42 , pp. 361-370
    • Fischer, S.E.1    Wickline, S.A.2    Lorenz, C.H.3
  • 3
    • 0025360257 scopus 로고
    • Interstudy reproducibility of dimensional and functional measurements between cine magnetic resonance studies in the morphologically abnormal left ventricle
    • Semelka RC, Tomei E, Wagner S, Mayo J, Caputo G, O'Sullivan M, Parmley WW, Chatterjee K, Wolfe C, Higgins CB. Interstudy reproducibility of dimensional and functional measurements between cine magnetic resonance studies in the morphologically abnormal left ventricle. Am Heart J 1990;119:1367-1373.
    • (1990) Am Heart J , vol.119 , pp. 1367-1373
    • Semelka, R.C.1    Tomei, E.2    Wagner, S.3    Mayo, J.4    Caputo, G.5    O'Sullivan, M.6    Parmley, W.W.7    Chatterjee, K.8    Wolfe, C.9    Higgins, C.B.10
  • 4
    • 0027512694 scopus 로고
    • Left ventricular measurements with cine and spin-echo MR imaging: A study of reproducibility with variance component analysis
    • Pattynama PM, Lamb HJ, van der Velde EA, van der Wall EE, de Roos A. Left ventricular measurements with cine and spin-echo MR imaging: a study of reproducibility with variance component analysis. Radiology 1993;187:261-8.
    • (1993) Radiology , vol.187 , pp. 261-268
    • Pattynama, P.M.1    Lamb, H.J.2    Van Der Velde, E.A.3    Van Der Wall, E.E.4    De Roos, A.5
  • 5
    • 0842304408 scopus 로고    scopus 로고
    • Interstudy reproducibility of right ventricular volumes, function, and mass with cardiovascular magnetic resonance
    • Grothues F, Moon JC, Bellenger NG, Smith GS, Klein HU, Pennell DJ. Interstudy reproducibility of right ventricular volumes, function, and mass with cardiovascular magnetic resonance. Am Heart J 2004;147:218-23.
    • (2004) Am Heart J , vol.147 , pp. 218-223
    • Grothues, F.1    Moon, J.C.2    Bellenger, N.G.3    Smith, G.S.4    Klein, H.U.5    Pennell, D.J.6
  • 6
    • 0034266456 scopus 로고    scopus 로고
    • Detection and quantification of valvular heart disease with dynamic cardiac MR imaging
    • Didier D, Ratib O, Lerch R, Friedli B. Detection and quantification of valvular heart disease with dynamic cardiac MR imaging. Radiographics 2000;20:1279-99.
    • (2000) Radiographics , vol.20 , pp. 1279-1299
    • Didier, D.1    Ratib, O.2    Lerch, R.3    Friedli, B.4
  • 8
    • 0347003637 scopus 로고    scopus 로고
    • Flow artifacts in steady-state free precession cine imaging
    • Storey P, Li W, Chen Q, Edelman RR. Flow artifacts in steady-state free precession cine imaging. Magn Reson Med 2004;51:115-22.
    • (2004) Magn Reson Med , vol.51 , pp. 115-122
    • Storey, P.1    Li, W.2    Chen, Q.3    Edelman, R.R.4
  • 9
    • 4744363360 scopus 로고    scopus 로고
    • On flow effects in balanced steady-state free precession imaging: Pictorial description, parameter dependence, and clinical implications
    • Markl M, Pelc NJ. On flow effects in balanced steady-state free precession imaging: pictorial description, parameter dependence, and clinical implications. J Magn Reson Imaging 2004;20:697-705.
    • (2004) J Magn Reson Imaging , vol.20 , pp. 697-705
    • Markl, M.1    Pelc, N.J.2
  • 10
    • 0036584937 scopus 로고    scopus 로고
    • Cardiovascular Flow Measurement with Phase-Contrast MR Imaging: Basic Facts and Implementation
    • Lotz J, Meier C, Leppert A, Galanski M. Cardiovascular Flow Measurement with Phase-Contrast MR Imaging: Basic Facts and Implementation. Radiographics 2002;22:65-71.
    • (2002) Radiographics , vol.22 , pp. 65-71
    • Lotz, J.1    Meier, C.2    Leppert, A.3    Galanski, M.4
  • 11
    • 3343019140 scopus 로고    scopus 로고
    • Time-resolved 3-dimensional velocity mapping in the thoracic aorta: Visualization of 3-directional blood flow patterns in healthy volunteers and patients
    • Markl M, Draney MT, Hope MD, Levin JM, Chan FP, Alley MT, Pelc NJ, Herfkens RJ. Time-resolved 3-dimensional velocity mapping in the thoracic aorta: visualization of 3-directional blood flow patterns in healthy volunteers and patients. J Comput Assist Tomogr 2004;28:459-68.
    • (2004) J Comput Assist Tomogr , vol.28 , pp. 459-468
    • Markl, M.1    Draney, M.T.2    Hope, M.D.3    Levin, J.M.4    Chan, F.P.5    Alley, M.T.6    Pelc, N.J.7    Herfkens, R.J.8
  • 12
    • 0035028867 scopus 로고    scopus 로고
    • Visualization of flow patterns distal to aortic valve prostheses in humans using a fast approach for cine 3D velocity mapping
    • Kozerke S, Hasenkam JM, Pedersen EM, Boesiger P. Visualization of flow patterns distal to aortic valve prostheses in humans using a fast approach for cine 3D velocity mapping. J Magn Reson Imaging 2001;13:690-8.
    • (2001) J Magn Reson Imaging , vol.13 , pp. 690-698
    • Kozerke, S.1    Hasenkam, J.M.2    Pedersen, E.M.3    Boesiger, P.4
  • 14
    • 0024318208 scopus 로고    scopus 로고
    • MR imaging of motion with spatial modulation of magnetization
    • Axel L, Dougherty L. MR imaging of motion with spatial modulation of magnetization. Radiology 171:841-5.
    • Radiology , vol.171 , pp. 841-845
    • Axel, L.1    Dougherty, L.2
  • 17
    • 0032752454 scopus 로고    scopus 로고
    • Cardiac motion tracking using CINE harmonic phase (HARP) magnetic resonance imaging
    • Osman NF, Kerwin WS, McVeigh ER, Prince JL. Cardiac motion tracking using CINE harmonic phase (HARP) magnetic resonance imaging. Magn Reson Med 1999;42:1048-60.
    • (1999) Magn Reson Med , vol.42 , pp. 1048-1060
    • Osman, N.F.1    Kerwin, W.S.2    McVeigh, E.R.3    Prince, J.L.4
  • 22
    • 0028122164 scopus 로고
    • Quantification of collateral blood flow in coarctation of the aorta by velocity encoded cine magnetic resonance imaging
    • Steffens JC, Bourne MW, Sakuma H, O'Sullivan M, Higgins CB. Quantification of collateral blood flow in coarctation of the aorta by velocity encoded cine magnetic resonance imaging. Circulation 1994;90:937-43.
    • (1994) Circulation , vol.90 , pp. 937-943
    • Steffens, J.C.1    Bourne, M.W.2    Sakuma, H.3    O'Sullivan, M.4    Higgins, C.B.5
  • 23
    • 0037306733 scopus 로고    scopus 로고
    • MR findings of collateral circulation are more accurate measures of hemodynamic significance than arm-leg blood pressure gradient after repair of coarctation of the aorta
    • Araoz PA, Reddy GP, Tarnoff H, Roge CL, Higgins CB. MR findings of collateral circulation are more accurate measures of hemodynamic significance than arm-leg blood pressure gradient after repair of coarctation of the aorta. J Magn Reson Imaging 2003;17:177-83.
    • (2003) J Magn Reson Imaging , vol.17 , pp. 177-183
    • Araoz, P.A.1    Reddy, G.P.2    Tarnoff, H.3    Roge, C.L.4    Higgins, C.B.5
  • 25
    • 0027443677 scopus 로고
    • Pulmonary regurgitation in the late postoperative follow-up of tetralogy of Fallot. Volumetric quantitation by nuclear magnetic resonance velocity mapping
    • Rebergen SA, Chin JG, Ottenkamp J, van der Wall EE, de Roos A. Pulmonary regurgitation in the late postoperative follow-up of tetralogy of Fallot. Volumetric quantitation by nuclear magnetic resonance velocity mapping. Circulation 1993;88:2257-2266.
    • (1993) Circulation , vol.88 , pp. 2257-2266
    • Rebergen, S.A.1    Chin, J.G.2    Ottenkamp, J.3    Van Der Wall, E.E.4    De Roos, A.5
  • 26
    • 14744290104 scopus 로고    scopus 로고
    • Optimal timing for pulmonary valve replacement in adults after tetralogy of Fallot repair
    • Therrien J, Provost Y, Merchant N, Williams W, Colman J, Webb G. Optimal timing for pulmonary valve replacement in adults after tetralogy of Fallot repair. Am J Cardiol 2005;95:779-82.
    • (2005) Am J Cardiol , vol.95 , pp. 779-782
    • Therrien, J.1    Provost, Y.2    Merchant, N.3    Williams, W.4    Colman, J.5    Webb, G.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.