메뉴 건너뛰기




Volumn 37, Issue 8, 2006, Pages 1-12

Real-time mandibular movement analysis system using four-dimensional cranial bone model

(8)  Otake, Yoshito a,d,e   Suzuki, Naoki a   Hattori, Asaki a   Shigeta, Yuko b,d,e,f,g,h,i   Ogawa, Takumi b,d,e,f,g,i   Fukushima, Shunji b,e,g,j,k   Kobayashi, Kaoru b,g,l,m,n,o   Uchiyama, Akihiko c,p,q,r  


Author keywords

Four dimensional movement analysis; Jaw movement analysis; Motion capture; Real time imaging

Indexed keywords

FOUR-DIMENSIONAL MOVEMENT ANALYSIS; JAW MOVEMENT ANALYSIS; MOTION CAPTURE; REAL-TIME IMAGING;

EID: 33745127391     PISSN: 08821666     EISSN: 1520684X     Source Type: Journal    
DOI: 10.1002/scj.20582     Document Type: Article
Times cited : (11)

References (25)
  • 1
    • 0034153710 scopus 로고    scopus 로고
    • Wireless optoelectronic recordings of mandibular and associated head-neck movements in man: A methodological study
    • Zafar H, Eriksson PO, Nordh E, Haggman-Henrikson B. Wireless optoelectronic recordings of mandibular and associated head-neck movements in man: A methodological study. J Oral Rehab 2000;27:227-238.
    • (2000) J Oral Rehab , vol.27 , pp. 227-238
    • Zafar, H.1    Eriksson, P.O.2    Nordh, E.3    Haggman-Henrikson, B.4
  • 3
    • 0038793628 scopus 로고    scopus 로고
    • Biomechanics of the human temporomandibular joint during chewing
    • Naejie M, Hofman N. Biomechanics of the human temporomandibular joint during chewing. J Dent Res 2003;82:528-531.
    • (2003) J Dent Res , vol.82 , pp. 528-531
    • Naejie, M.1    Hofman, N.2
  • 5
    • 33745141003 scopus 로고    scopus 로고
    • Using TRIMET, a device for measuring jaw movement with six degrees of freedom
    • Kawano S. Using TRIMET, a device for measuring jaw movement with six degrees of freedom. J Prosthodontics 1998;42:913-920.
    • (1998) J Prosthodontics , vol.42 , pp. 913-920
    • Kawano, S.1
  • 6
    • 33745159116 scopus 로고    scopus 로고
    • Clinical development of a device to measure jaw movement with six degrees of freedom: Using the device to measure jaw movement with six degrees of freedom for functional assessment of children's jaws
    • Nakada M, Yamazaki Y, Hayazaki N. Clinical development of a device to measure jaw movement with six degrees of freedom: Using the device to measure jaw movement with six degrees of freedom for functional assessment of children's jaws. J Dent Prosthesis 1998;42:921-927.
    • (1998) J Dent Prosthesis , vol.42 , pp. 921-927
    • Nakada, M.1    Yamazaki, Y.2    Hayazaki, N.3
  • 7
    • 0036213986 scopus 로고    scopus 로고
    • A simple and inexpensive system for monitoring jaw movements in ambulatory humans
    • Flavel SC, Nordstrom MA, Miles TS. A simple and inexpensive system for monitoring jaw movements in ambulatory humans. J Biomech 2002;35:573-577.
    • (2002) J Biomech , vol.35 , pp. 573-577
    • Flavel, S.C.1    Nordstrom, M.A.2    Miles, T.S.3
  • 8
    • 0642334599 scopus 로고    scopus 로고
    • Three-dimensional visualization of the craniofacial patient: Volume segmentation, data integration and animation
    • Enciso R, Memon A, Mah J. Three-dimensional visualization of the craniofacial patient: Volume segmentation, data integration and animation. Orthod Craniofacial Res 2003;6(Suppl 1):66-71.
    • (2003) Orthod Craniofacial Res , vol.6 , Issue.1 SUPPL. , pp. 66-71
    • Enciso, R.1    Memon, A.2    Mah, J.3
  • 9
    • 33745158435 scopus 로고    scopus 로고
    • Analysis of three-dimensional restructuring and lower jaw movement in CT images of the temporomandibular joint
    • Oyama N. Analysis of three-dimensional restructuring and lower jaw movement in CT images of the temporomandibular joint. J Dent Aichi Hosp 1996;34:192-201.
    • (1996) J Dent Aichi Hosp , vol.34 , pp. 192-201
    • Oyama, N.1
  • 10
    • 0030864921 scopus 로고    scopus 로고
    • A system for three-dimensional visualization of human jaw motion in speech
    • Guiard-Marigny T, Ostry DJ. A system for three-dimensional visualization of human jaw motion in speech. JSLHR 1997;40:1118-1121.
    • (1997) JSLHR , vol.40 , pp. 1118-1121
    • Guiard-Marigny, T.1    Ostry, D.J.2
  • 11
    • 0037302552 scopus 로고    scopus 로고
    • Mandibular kinematics represented by a non-orthogonal floating axis joint coordinate system
    • Leader JK, Boston JR, Debski RE, Rudy TE. Mandibular kinematics represented by a non-orthogonal floating axis joint coordinate system. J Biomech 2003;36:275-281.
    • (2003) J Biomech , vol.36 , pp. 275-281
    • Leader, J.K.1    Boston, J.R.2    Debski, R.E.3    Rudy, T.E.4
  • 12
    • 0642303895 scopus 로고    scopus 로고
    • Dynamic modeling and jaw biomechanics
    • Hannam AG. Dynamic modeling and jaw biomechanics. Orthod Craniofacial Res 2003; 6(Suppl 1):59-65.
    • (2003) Orthod Craniofacial Res , vol.6 , Issue.1 SUPPL. , pp. 59-65
    • Hannam, A.G.1
  • 15
    • 33745130163 scopus 로고    scopus 로고
    • Development of a system to display jaw movements using 3D-CT images (three-dimensional display using an FEM model)
    • Ino T, Hatahiro T, Sekiana N, Somi H, Ujibashi S. Development of a system to display jaw movements using 3D-CT images (three-dimensional display using an FEM model). J Assoc Oromaxillofacial Biomech 1997;3:3-4.
    • (1997) J Assoc Oromaxillofacial Biomech , vol.3 , pp. 3-4
    • Ino, T.1    Hatahiro, T.2    Sekiana, N.3    Somi, H.4    Ujibashi, S.5
  • 16
    • 5644267915 scopus 로고    scopus 로고
    • Accuracy assessment and interpretation for optical tracking systems
    • Visualization, Image-Guided Procedures, and Display
    • Wiles AD, Thompson DG, Thompson DG, Framtz DD. Accuracy assessment and interpretation for optical tracking systems. Medical Imaging 2004 Proc 5367, Visualization, Image-Guided Procedures, and Display, p 421-432, 2004.
    • (2004) Medical Imaging 2004 Proc , vol.5367 , pp. 421-432
    • Wiles, A.D.1    Thompson, D.G.2    Thompson, D.G.3    Framtz, D.D.4
  • 21
    • 1242287062 scopus 로고    scopus 로고
    • Automated fiducial marker detection for patient registration in imageguided neurosurgery
    • Krishnan R, Hermann E, Wolff R. Automated fiducial marker detection for patient registration in imageguided neurosurgery. Comput Aided Surg 2003;8:17-23.
    • (2003) Comput Aided Surg , vol.8 , pp. 17-23
    • Krishnan, R.1    Hermann, E.2    Wolff, R.3
  • 23
    • 0036556247 scopus 로고    scopus 로고
    • Laser surface scanning for patient registration in intracranial image-guided surgery
    • Raabe A, Krishman R, Wolff R, Hermann E, Zimmermann M, Seifert V. Laser surface scanning for patient registration in intracranial image-guided surgery. Neurosurgery 2002;50:797-803.
    • (2002) Neurosurgery , vol.50 , pp. 797-803
    • Raabe, A.1    Krishman, R.2    Wolff, R.3    Hermann, E.4    Zimmermann, M.5    Seifert, V.6
  • 24
    • 0031665414 scopus 로고    scopus 로고
    • Accuracy of registration methods in frameless stereotaxis
    • Helm PA, Eckel TS. Accuracy of registration methods in frameless stereotaxis. Comput Aided Surg 1998;3:51-56.
    • (1998) Comput Aided Surg , vol.3 , pp. 51-56
    • Helm, P.A.1    Eckel, T.S.2
  • 25
    • 84945574619 scopus 로고    scopus 로고
    • Experimental protocol of accuracy evaluation of 6-D localizers for cpmputer-inte grated surgery: Application to four optical localizers
    • Chassat F, Lavalee S. Experimental protocol of accuracy evaluation of 6-D localizers for cpmputer-inte grated surgery: Application to four optical localizers. Lect Notes Comput Sci 1998;1496:277-284.
    • (1998) Lect Notes Comput Sci , vol.1496 , pp. 277-284
    • Chassat, F.1    Lavalee, S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.