메뉴 건너뛰기




Volumn 95, Issue 2, 2006, Pages 119-127

RSA applications in monitoring of fracture healing in clinical trials

Author keywords

Accuracy; Fracture healing; Precision; Radiostereometric analysis

Indexed keywords

BIOMATERIAL; CALCIUM PHOSPHATE; CEMENT; HYDROXYAPATITE; OSTEOGENIC PROTEIN 1;

EID: 33745110941     PISSN: 14574969     EISSN: None     Source Type: Journal    
DOI: 10.1177/145749690609500207     Document Type: Review
Times cited : (15)

References (53)
  • 1
    • 0024388994 scopus 로고
    • Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system
    • Selvik G: Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system. Acta Orthop Scand Suppl 1989;232:1-51
    • (1989) Acta Orthop Scand Suppl , vol.232 , pp. 1-51
    • Selvik, G.1
  • 2
    • 0024317955 scopus 로고
    • Roentgen stereophotogrammetry. Review of orthopedic applications
    • Kärrholm J: Roentgen stereophotogrammetry. Review of orthopedic applications. Acta Orthop Scand 1989;60:491-503
    • (1989) Acta Orthop Scand , vol.60 , pp. 491-503
    • Kärrholm, J.1
  • 3
    • 0027199753 scopus 로고
    • Knee motion after tibial osteotomy for arthrosis. Kinematic analysis of 7 patients
    • Weidenhielm L, Wykman A, Lundberg A, Brostrom LA: Knee motion after tibial osteotomy for arthrosis. Kinematic analysis of 7 patients. Acta Orthop Scand 1993;64:317-319
    • (1993) Acta Orthop Scand , vol.64 , pp. 317-319
    • Weidenhielm, L.1    Wykman, A.2    Lundberg, A.3    Brostrom, L.A.4
  • 4
    • 0032142933 scopus 로고    scopus 로고
    • A kinematic study of the cervical spine before and after segmental arthrodesis
    • Fuller DA, Kirkpatrick JS, Emery SE, Wilber RG, Davy DT: A kinematic study of the cervical spine before and after segmental arthrodesis. Spine 1998;23:1649-1656
    • (1998) Spine , vol.23 , pp. 1649-1656
    • Fuller, D.A.1    Kirkpatrick, J.S.2    Emery, S.E.3    Wilber, R.G.4    Davy, D.T.5
  • 5
    • 0028034860 scopus 로고
    • Does early micromotion of femoral stem prostheses matter? 4-7-Year stereoradiographic follow-up of 84 cemented prostheses
    • Kärrholm J, Borssén B, Löwenhielm G, Snorrason F: Does early micromotion of femoral stem prostheses matter? 4-7-year stereoradiographic follow-up of 84 cemented prostheses. J Bone Joint Surg Br 1994;76:912-917
    • (1994) J Bone Joint Surg Br , vol.76 , pp. 912-917
    • Kärrholm, J.1    Borssén, B.2    Löwenhielm, G.3    Snorrason, F.4
  • 7
    • 0018864441 scopus 로고
    • Movement of the cleft maxilla in infants relative to the frontal bone. A roentgen stereophotogrammetric study with the aid of metallic implants
    • Rune B, Sarnäs K V, Selvik G, Jacobsson S: Movement of the cleft maxilla in infants relative to the frontal bone. A roentgen stereophotogrammetric study with the aid of metallic implants. Cleft Palate J 1980;17:155-174
    • (1980) Cleft Palate J , vol.17 , pp. 155-174
    • Rune, B.1    Sarnäs, K.V.2    Selvik, G.3    Jacobsson, S.4
  • 8
    • 0022746699 scopus 로고
    • Roentgen stereometry in the study of craniofacial anomalies - The state of the art in Sweden
    • Rune B, Sarnäs K V, Selvik G, Jacobsson S: Roentgen stereometry in the study of craniofacial anomalies - the state of the art in Sweden. Br J Orthod 1986;13:151-157
    • (1986) Br J Orthod , vol.13 , pp. 151-157
    • Rune, B.1    Sarnäs, K.V.2    Selvik, G.3    Jacobsson, S.4
  • 10
    • 0019988939 scopus 로고
    • Stereophotogrammetric evaluation of tracheal volumes in the rabbit
    • Lindahl S, Ranklev E, Selvik G, Ekelund L: Stereophotogrammetric evaluation of tracheal volumes in the rabbit. Br J Anaesth 1982;54:997-1002
    • (1982) Br J Anaesth , vol.54 , pp. 997-1002
    • Lindahl, S.1    Ranklev, E.2    Selvik, G.3    Ekelund, L.4
  • 11
    • 0022726839 scopus 로고
    • Some aspects of knee joint kinematics in rheumatoid arthritis as studied with roentgen stereophotogrammetry
    • Eberhardt K B, Selvik G: Some aspects of knee joint kinematics in rheumatoid arthritis as studied with roentgen stereophotogrammetry. Clin Rheumatol 1986;5:201-209
    • (1986) Clin Rheumatol , vol.5 , pp. 201-209
    • Eberhardt, K.B.1    Selvik, G.2
  • 12
    • 0018382181 scopus 로고
    • Motion of bones and volume changes in the neurocranium after craniectomy in Crouzon's disease. A roentgen stereometric study
    • Rune B, Selvik G, Kreiborg S, Sarnäs KV, Kågström E: Motion of bones and volume changes in the neurocranium after craniectomy in Crouzon's disease. A roentgen stereometric study. J Neurosurg 1979;50:494-498
    • (1979) J Neurosurg , vol.50 , pp. 494-498
    • Rune, B.1    Selvik, G.2    Kreiborg, S.3    Sarnäs, K.V.4    Kågström, E.5
  • 13
    • 0018191965 scopus 로고
    • Antineoplastic-drug effect evaluated with a new X-ray stereophotographic measurement of the tumour volume
    • Tropé C, Selvik G, Kullander S, Mattsson W, Mühlow A, Åstedt B: Antineoplastic-drug effect evaluated with a new X-ray stereophotographic measurement of the tumour volume. Ann Chir Gynaecol 1978;67:82-84
    • (1978) Ann Chir Gynaecol , vol.67 , pp. 82-84
    • Tropé, C.1    Selvik, G.2    Kullander, S.3    Mattsson, W.4    Mühlow, A.5    Åstedt, B.6
  • 14
    • 14244267669 scopus 로고    scopus 로고
    • Accuracy and precision of radiostereometric analysis in the measurement of three-dimensional micromotion in a fracture model of the distal radius
    • Madanat R, Mäkinen TJ, Moritz N, Mattila KT, Aro HT: Accuracy and precision of radiostereometric analysis in the measurement of three-dimensional micromotion in a fracture model of the distal radius. J Orthop Res 2005;23:481-488
    • (2005) J Orthop Res , vol.23 , pp. 481-488
    • Madanat, R.1    Mäkinen, T.J.2    Moritz, N.3    Mattila, K.T.4    Aro, H.T.5
  • 15
    • 0036316748 scopus 로고    scopus 로고
    • Experimental assessment of precision and accuracy of radiostereometric analysis for the determination of polyethylene wear in a total hip replacement model
    • Bragdon CR, Malchau H, Yuan X, Perinchief R, Kärrholm J, Börlin N, Estok DM, Harris WH: Experimental assessment of precision and accuracy of radiostereometric analysis for the determination of polyethylene wear in a total hip replacement model. J Orthop Res 2002;20:688-695
    • (2002) J Orthop Res , vol.20 , pp. 688-695
    • Bragdon, C.R.1    Malchau, H.2    Yuan, X.3    Perinchief, R.4    Kärrholm, J.5    Börlin, N.6    Estok, D.M.7    Harris, W.H.8
  • 16
    • 0035215807 scopus 로고    scopus 로고
    • Accuracy and precision of radiostereometric analysis in the measurement of THR femoral component translations: Human and canine in vitro models
    • Önsten I, Berzins A, Shott S, Sumner DR: Accuracy and precision of radiostereometric analysis in the measurement of THR femoral component translations: human and canine in vitro models. J Orthop Res 2001;19:1162-1167
    • (2001) J Orthop Res , vol.19 , pp. 1162-1167
    • Önsten, I.1    Berzins, A.2    Shott, S.3    Sumner, D.R.4
  • 18
    • 0022522401 scopus 로고
    • Micromotion in knee arthroplasty. A roentgen stereophotogrammetric analysis of tibial component fixation
    • Ryd L: Micromotion in knee arthroplasty. A roentgen stereophotogrammetric analysis of tibial component fixation. Acta Orthop Scand Suppl 1986;220:1-80
    • (1986) Acta Orthop Scand Suppl , vol.220 , pp. 1-80
    • Ryd, L.1
  • 20
    • 0036678602 scopus 로고    scopus 로고
    • Migration of the femoral stem after impaction bone grafting. First results of an ongoing, randomised study of the exeter and elite plus femoral stems using radiostereometric analysis
    • van Doorn WJ, ten Have BL, van Biezen FC, Hop WC, Ginai AZ, Verhaar JA: Migration of the femoral stem after impaction bone grafting. First results of an ongoing, randomised study of the exeter and elite plus femoral stems using radiostereometric analysis. J Bone Joint Surg 2002;84-B:825-831
    • (2002) J Bone Joint Surg , vol.84 , pp. 825-831
    • Van Doorn, W.J.1    Ten Have, B.L.2    Van Biezen, F.C.3    Hop, W.C.4    Ginai, A.Z.5    Verhaar, J.A.6
  • 21
    • 0034919889 scopus 로고    scopus 로고
    • Evaluation of accuracy and precision of bone markers for the measurement of migration of hip prostheses. A comparison of conventional measurements
    • Biedermann R, Stockl B, Krismer M, Mayrhofer P, Ornstein E, Franzen H: Evaluation of accuracy and precision of bone markers for the measurement of migration of hip prostheses. A comparison of conventional measurements. J Bone Joint Surg 2001;83-B:767-771
    • (2001) J Bone Joint Surg , vol.83 , pp. 767-771
    • Biedermann, R.1    Stockl, B.2    Krismer, M.3    Mayrhofer, P.4    Ornstein, E.5    Franzen, H.6
  • 22
    • 0036135893 scopus 로고    scopus 로고
    • The precision of radiostereometric measurements. Manual vs. digital measurements
    • Börlin N, Thien T, Kärrholm J: The precision of radiostereometric measurements. Manual vs. digital measurements. J Biomech 2002;35:69-79
    • (2002) J Biomech , vol.35 , pp. 69-79
    • Börlin, N.1    Thien, T.2    Kärrholm, J.3
  • 23
    • 0141743630 scopus 로고    scopus 로고
    • The migration of femoral components after total hip replacement surgery: Accuracy and precision of software-aided measurements
    • Decking J, Schuetz U, Decking R, Puhl W: The migration of femoral components after total hip replacement surgery: accuracy and precision of software-aided measurements. Skeletal Radiol 2003;32:521-525
    • (2003) Skeletal Radiol , vol.32 , pp. 521-525
    • Decking, J.1    Schuetz, U.2    Decking, R.3    Puhl, W.4
  • 24
    • 0035073910 scopus 로고    scopus 로고
    • Radiostereometric analysis of distal radial fracture displacement during treatment: A randomized study comparing Norian SRS and external fixation in 23 patients
    • Kopylov P, Aspenberg P, Yuan X, Ryd L: Radiostereometric analysis of distal radial fracture displacement during treatment: a randomized study comparing Norian SRS and external fixation in 23 patients. Acta Orthop Scand 2001;72:57-61
    • (2001) Acta Orthop Scand , vol.72 , pp. 57-61
    • Kopylov, P.1    Aspenberg, P.2    Yuan, X.3    Ryd, L.4
  • 25
    • 0024380792 scopus 로고
    • Stability of femoral neck fractures. A postoperative roentgen stereophotogrammetric analysis
    • Ragnarsson J I, Hansson LI, Kärrholm J: Stability of femoral neck fractures. A postoperative roentgen stereophotogrammetric analysis. Acta Orthop Scand 1989;60:283-287
    • (1989) Acta Orthop Scand , vol.60 , pp. 283-287
    • Ragnarsson, J.I.1    Hansson, L.I.2    Kärrholm, J.3
  • 27
    • 0026539193 scopus 로고
    • The accuracy of measurements of femoral neck fractures. Conventional radiography versus roentgen stereophotogrammetric analysis
    • Ragnarsson JI, Eliasson P, Karrholm J, Lundstrom B: The accuracy of measurements of femoral neck fractures. Conventional radiography versus roentgen stereophotogrammetric analysis. Acta Orthop Scand 1992;63:152-156
    • (1992) Acta Orthop Scand , vol.63 , pp. 152-156
    • Ragnarsson, J.I.1    Eliasson, P.2    Karrholm, J.3    Lundstrom, B.4
  • 28
    • 0026444793 scopus 로고
    • Factors influencing postoperative movement in displaced femoral neck fractures: Evaluation by conventional radiography and stereoradiography
    • Ragnarsson JI, Karrholm J: Factors influencing postoperative movement in displaced femoral neck fractures: evaluation by conventional radiography and stereoradiography. J Orthop Trauma 1992;6:152-158
    • (1992) J Orthop Trauma , vol.6 , pp. 152-158
    • Ragnarsson, J.I.1    Karrholm, J.2
  • 29
    • 0142119539 scopus 로고    scopus 로고
    • Stability of internally fixed femoral neck fractures augmented with resorbable cement. A prospective randomized study using radiostereometry
    • Mattsson P, Larsson S: Stability of internally fixed femoral neck fractures augmented with resorbable cement. A prospective randomized study using radiostereometry. Scand J Surg 2003;92:215-219
    • (2003) Scand J Surg , vol.92 , pp. 215-219
    • Mattsson, P.1    Larsson, S.2
  • 30
    • 8344276630 scopus 로고    scopus 로고
    • Unstable trochanteric fractures augmented with calcium phosphate cement. A prospective randomized study using radiostereometry to measure fracture stability
    • Mattsson P, Larsson S: Unstable trochanteric fractures augmented with calcium phosphate cement. A prospective randomized study using radiostereometry to measure fracture stability. Scand J Surg 2004;93:223-228
    • (2004) Scand J Surg , vol.93 , pp. 223-228
    • Mattsson, P.1    Larsson, S.2
  • 31
    • 0028341574 scopus 로고
    • Stability of the elevated fragment in tibial plateau fractures. A radiographic stereophotogrammetric study of postoperative healing
    • Ryd L, Toksvig-Larsen S: Stability of the elevated fragment in tibial plateau fractures. A radiographic stereophotogrammetric study of postoperative healing. Int Orthop 1994;18:131-134
    • (1994) Int Orthop , vol.18 , pp. 131-134
    • Ryd, L.1    Toksvig-Larsen, S.2
  • 32
    • 84872864716 scopus 로고    scopus 로고
    • Augmentation of tibial plateau fractures with calcium phosphate cement. A randomized study using radiostereometry
    • October 8-10, Florida
    • Larsson S, Berg P, Sagerfors M: Augmentation of tibial plateau fractures with calcium phosphate cement. A randomized study using radiostereometry. Orthopaedic Trauma Association, 2004 Annual Meeting, October 8-10, Florida
    • (2004) Orthopaedic Trauma Association
    • Larsson, S.1    Berg, P.2    Sagerfors, M.3
  • 33
    • 0028277347 scopus 로고
    • Biodegradable fixation of ankle fractures. A roentgen stereophotogrammetric study of 32 cases
    • Ahl T, Dalen N, Lundberg A, Wykman A: Biodegradable fixation of ankle fractures. A roentgen stereophotogrammetric study of 32 cases. Acta Orthop Scand 1994;65:166-170
    • (1994) Acta Orthop Scand , vol.65 , pp. 166-170
    • Ahl, T.1    Dalen, N.2    Lundberg, A.3    Wykman, A.4
  • 34
    • 0023598397 scopus 로고
    • Early weight bearing of displaced ankle fractures
    • Ahl T, Dalén, Holmberg S, Selvik G: Early weight bearing of displaced ankle fractures. Acta Orthop Scand 1987;58:535-538
    • (1987) Acta Orthop Scand , vol.58 , pp. 535-538
    • Ahl, T.1    Dalén2    Holmberg, S.3    Selvik, G.4
  • 38
    • 0017105903 scopus 로고
    • Kinematic analysis of posterolateral fusion in the lumbosacral spine
    • Olsson TH, Selvik G, Willner S: Kinematic analysis of posterolateral fusion in the lumbosacral spine. Acta Radiol Diagn (Stockh) 1976;17:519-530
    • (1976) Acta Radiol Diagn (Stockh) , vol.17 , pp. 519-530
    • Olsson, T.H.1    Selvik, G.2    Willner, S.3
  • 39
    • 0017571764 scopus 로고
    • Mobility in the lumbosacral spine after fusion studied with the aid of roentgen stereophotogrammetry
    • Olsson TH, Selvik G, Willner S: Mobility in the lumbosacral spine after fusion studied with the aid of roentgen stereophotogrammetry. Clin Orthop Relat Res 1977;(129):181-190
    • (1977) Clin Orthop Relat Res , Issue.129 , pp. 181-190
    • Olsson, T.H.1    Selvik, G.2    Willner, S.3
  • 40
    • 0025370279 scopus 로고
    • Mobility of the lower lumbar spine after posterolateral fusion determined by roentgen stereophotogrammetric analysis
    • Johnsson R, Selvik G, Strömqvist B, Sundén G: Mobility of the lower lumbar spine after posterolateral fusion determined by roentgen stereophotogrammetric analysis. Spine 1990;15:347-350
    • (1990) Spine , vol.15 , pp. 347-350
    • Johnsson, R.1    Selvik, G.2    Strömqvist, B.3    Sundén, G.4
  • 41
    • 0036897076 scopus 로고    scopus 로고
    • Randomized radiostereometric study comparing osteogenic protein-1 (BMP-7) and autograft bone in human noninstrumented posterolateral lumbar fusion: 2002 Volvo Award in clinical studies
    • Johnsson R, Stromqvist B, Aspenberg P: Randomized radiostereometric study comparing osteogenic protein-1 (BMP-7) and autograft bone in human noninstrumented posterolateral lumbar fusion: 2002 Volvo Award in clinical studies. Spine 2002;27:2654-2661
    • (2002) Spine , vol.27 , pp. 2654-2661
    • Johnsson, R.1    Stromqvist, B.2    Aspenberg, P.3
  • 42
    • 0031692583 scopus 로고    scopus 로고
    • One-level cervical spine fusion. A randomized study, with or without plate fixation, using radiostereometry in 27 patients
    • Zoega B, Kärrholm J, Lind B: One-level cervical spine fusion. A randomized study, with or without plate fixation, using radiostereometry in 27 patients. Acta Orthop Scand 1998;69:363-368
    • (1998) Acta Orthop Scand , vol.69 , pp. 363-368
    • Zoega, B.1    Kärrholm, J.2    Lind, B.3
  • 44
    • 24144457292 scopus 로고    scopus 로고
    • Fixation stability following high tibial osteotomy: A radiostereometric analysis
    • Pape D, Adam F, Seil R, Georg T, Kohn D: Fixation stability following high tibial osteotomy: a radiostereometric analysis. J Knee Surg 2005;18:108-115
    • (2005) J Knee Surg , vol.18 , pp. 108-115
    • Pape, D.1    Adam, F.2    Seil, R.3    Georg, T.4    Kohn, D.5
  • 45
    • 0018147087 scopus 로고
    • A roentgen stereophotogrammetric investigation of innominate osteotomy (Salter)
    • Hansson LI, Olsson TH, Selvik G, Sundén G: A roentgen stereophotogrammetric investigation of innominate osteotomy (Salter). Acta Orthop Scand 1978;49:68-72
    • (1978) Acta Orthop Scand , vol.49 , pp. 68-72
    • Hansson, L.I.1    Olsson, T.H.2    Selvik, G.3    Sundén, G.4
  • 47
    • 0034132382 scopus 로고    scopus 로고
    • Accurate accuracy assessment: Review of basic principles
    • Ranstam J, Ryd L, Önsten I: Accurate accuracy assessment: review of basic principles. Acta Orthop Scand 2000;71:106-108
    • (2000) Acta Orthop Scand , vol.71 , pp. 106-108
    • Ranstam, J.1    Ryd, L.2    Önsten, I.3
  • 48
    • 0033865714 scopus 로고    scopus 로고
    • Methods for determining the accuracy of radiostereometric analysis (RSA)
    • Ryd L, Yuan X, Löfgren H: Methods for determining the accuracy of radiostereometric analysis (RSA). Acta Orthop Scand 2000;71:403-408
    • (2000) Acta Orthop Scand , vol.71 , pp. 403-408
    • Ryd, L.1    Yuan, X.2    Löfgren, H.3
  • 49
    • 10944233565 scopus 로고    scopus 로고
    • Accuracy of radiographic and radiostereometric wear measurement of different hip prostheses: An experimental study
    • von Schewelov, Sanzén L, Börlin N, Markusson P, Önsten I: Accuracy of radiographic and radiostereometric wear measurement of different hip prostheses: an experimental study. Acta Orthop Scand 2004;75:691-700
    • (2004) Acta Orthop Scand , vol.75 , pp. 691-700
    • Von Schewelov1    Sanzén, L.2    Börlin, N.3    Markusson, P.4    Önsten, I.5
  • 50
    • 1842853898 scopus 로고    scopus 로고
    • Comparison of two digital radiostereometric analysis methods in the determination of femoral head penetration in a total hip replacement phantom
    • Bragdon CR, Estok DM, Malchau H, Kärrholm J, Yuan X, Bourne R, Veldhoven J, Harris WH: Comparison of two digital radiostereometric analysis methods in the determination of femoral head penetration in a total hip replacement phantom. J Orthop Res 2004;22:659-664
    • (2004) J Orthop Res , vol.22 , pp. 659-664
    • Bragdon, C.R.1    Estok, D.M.2    Malchau, H.3    Kärrholm, J.4    Yuan, X.5    Bourne, R.6    Veldhoven, J.7    Harris, W.H.8
  • 51
    • 1042279607 scopus 로고    scopus 로고
    • Technical feasibility and precision of radiostereometric analysis as an outcome measure in canine cemented total hip replacement
    • Allen MJ, Hartmann SM, Sacks JM, Calabrese J, Brown PR: Technical feasibility and precision of radiostereometric analysis as an outcome measure in canine cemented total hip replacement. J Orthop Sci 2004;9:66-75
    • (2004) J Orthop Sci , vol.9 , pp. 66-75
    • Allen, M.J.1    Hartmann, S.M.2    Sacks, J.M.3    Calabrese, J.4    Brown, P.R.5
  • 52
    • 18844467602 scopus 로고    scopus 로고
    • Precision measurements of the RSA method using a phantom model of hip prosthesis
    • Mäkinen TJ, Koort JK, Mattila KT, Aro HT: Precision measurements of the RSA method using a phantom model of hip prosthesis. J Biomech 2004;37:487-493
    • (2004) J Biomech , vol.37 , pp. 487-493
    • Mäkinen, T.J.1    Koort, J.K.2    Mattila, K.T.3    Aro, H.T.4
  • 53
    • 0027938815 scopus 로고
    • Micromotion of femoral stems in total hip arthroplasty. A randomized study of cemented, hydroxyapatite-coated, and porous-coated stems with roentgen stereophotogrammetric analysis
    • Kärrholm J, Malchau H, Snorrason F, Herberts P: Micromotion of femoral stems in total hip arthroplasty. A randomized study of cemented, hydroxyapatite-coated, and porous-coated stems with roentgen stereophotogrammetric analysis. J Bone Joint Surg Am 1994;76:1692-1705
    • (1994) J Bone Joint Surg Am , vol.76 , pp. 1692-1705
    • Kärrholm, J.1    Malchau, H.2    Snorrason, F.3    Herberts, P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.