메뉴 건너뛰기




Volumn 23, Issue 2, 2005, Pages 481-488

Accuracy and precision of radiostereometric analysis in the measurement of three-dimensional micromotion in a fracture model of the distal radius

Author keywords

Accuracy; Distal radius; Fracture; Precision; Radiostereometric analysis

Indexed keywords

ACCURACY; ARTICLE; CALCULATION; COLLES FRACTURE; FEASIBILITY STUDY; MONITORING; MOTION; OSTEOMETRY; PREDICTION; PRIORITY JOURNAL; RADIUS FRACTURE; REGRESSION ANALYSIS; SIMULATION; THREE DIMENSIONAL IMAGING; X RAY FILM;

EID: 14244267669     PISSN: 07360266     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.orthres.2004.07.002     Document Type: Article
Times cited : (29)

References (29)
  • 2
    • 0028293371 scopus 로고
    • Early and late displacement of fractures of the distal radius. The prediction of instability
    • M. Altissimi G.B. Mancini A. Azzara E. Ciaffoloni Early and late displacement of fractures of the distal radius. The prediction of instability Int Orthop 18 1994 61-65
    • (1994) Int. Orthop. , vol.18 , pp. 61-65
    • Altissimi, M.1    Mancini, G.B.2    Azzara, A.3    Ciaffoloni, E.4
  • 3
    • 0025877469 scopus 로고
    • Minor axial shortening of the radius affects outcome of Colles' fracture treatment
    • H.T. Aro T. Koivunen Minor axial shortening of the radius affects outcome of Colles fracture treatment J Hand Surg 16-A 1991 392-398
    • (1991) J. Hand Surg. , vol.16 A , pp. 392-398
    • Aro, H.T.1    Koivunen, T.2
  • 4
    • 0004077698 scopus 로고
    • ASTM. Standard practice for use of the terms precision and bias in ASTM test methods. Designation: E 177a-190a (reapproved 1996)
    • ASTM. Annual Book of ASTM Standards. Standard practice for use of the terms precision and bias in ASTM test methods. Designation: E 177a-190a (reapproved 1996), 1990
    • (1990) Annual Book of ASTM Standards
  • 5
    • 0034919889 scopus 로고    scopus 로고
    • Evaluation of accuracy and precision of bone markers for the measurement of migration of hip prostheses. A comparison of conventional measurements
    • R. Biedermann B. Stockl M. Krismer et al. Evaluation of accuracy and precision of bone markers for the measurement of migration of hip prostheses. A comparison of conventional measurements J Bone Joint Surg 83-B 2001 767-771
    • (2001) J. Bone Joint Surg. , vol.83 B , pp. 767-771
    • Biedermann, R.1    Stockl, B.2    Krismer, M.3
  • 6
    • 0036135893 scopus 로고    scopus 로고
    • The precision of radiostereometric measurements. Manual vs. digital measurements
    • N. Börlin T. Thien J. Kärrholm The precision of radiostereometric measurements. Manual vs. digital measurements J Biomech 35 2002 69-79
    • (2002) J. Biomech. , vol.35 , pp. 69-79
    • Börlin, N.1    Thien, T.2    Kärrholm, J.3
  • 7
    • 0036316748 scopus 로고    scopus 로고
    • Experimental assessment of precision and accuracy of radiostereometric analysis for the determination of polyethylene wear in a total hip replacement model
    • C.R. Bragdon H. Malchau X. Yuan et al. Experimental assessment of precision and accuracy of radiostereometric analysis for the determination of polyethylene wear in a total hip replacement model J Orthop Res 20 2002 688-695
    • (2002) J. Orthop. Res. , vol.20 , pp. 688-695
    • Bragdon, C.R.1    Malchau, H.2    Yuan, X.3
  • 9
    • 0141743630 scopus 로고    scopus 로고
    • The migration of femoral components after total hip replacement surgery: Accuracy and precision of software-aided measurements
    • J. Decking U. Schuetz R. Decking W. Puhl The migration of femoral components after total hip replacement surgery: Accuracy and precision of software-aided measurements Skeletal Radiol 32 2003 521-525
    • (2003) Skeletal Radiol. , vol.32 , pp. 521-525
    • Decking, J.1    Schuetz, U.2    Decking, R.3    Puhl, W.4
  • 10
    • 0028574302 scopus 로고
    • Prediction of secondary displacement in Colles' fracture
    • L.M. Hove E. Solheim R. Skjeie F.K. Sorensen Prediction of secondary displacement in Colles' fracture J Hand Surg 19-B 1994 731-736
    • (1994) J. Hand Surg. , vol.19 B , pp. 731-736
    • Hove, L.M.1    Solheim, E.2    Skjeie, R.3    Sorensen, F.K.4
  • 11
    • 0036361455 scopus 로고    scopus 로고
    • Complications following distal radial fractures
    • J.B. Jupiter D.L. Fernandez Complications following distal radial fractures Instr Course Lect 51 2002 203-219
    • (2002) Instr. Course Lect. , vol.51 , pp. 203-219
    • Jupiter, J.B.1    Fernandez, D.L.2
  • 12
    • 0030454626 scopus 로고    scopus 로고
    • Operative treatment of volar intra-articular fractures of the distal end of the radius
    • J.B. Jupiter D.L. Fernandez C.L. Toh et al. Operative treatment of volar intra-articular fractures of the distal end of the radius J Bone Joint Surg 78-A 1996 1817-1828
    • (1996) J. Bone Joint Surg. , vol.78 A , pp. 1817-1828
    • Jupiter, J.B.1    Fernandez, D.L.2    Toh, C.L.3
  • 13
    • 0027226343 scopus 로고
    • The operative treatment of intraarticular fractures of the distal radius
    • J.B. Jupiter H. Lipton The operative treatment of intraarticular fractures of the distal radius Clin Orthop 292 1993 48-61
    • (1993) Clin. Orthop. , vol.292 , pp. 48-61
    • Jupiter, J.B.1    Lipton, H.2
  • 14
    • 0343118727 scopus 로고    scopus 로고
    • Radiostereometry of hip prostheses. Review of methodology and clinical results
    • J. Kärrholm P. Herberts P. Hultmark et al. Radiostereometry of hip prostheses. Review of methodology and clinical results Clin Orthop 344 1997 94-110
    • (1997) Clin. Orthop. , vol.344 , pp. 94-110
    • Kärrholm, J.1    Herberts, P.2    Hultmark, P.3
  • 15
    • 0022485799 scopus 로고
    • Intra-articular fractures of the distal end of the radius in young adults
    • J.L. Knirk J.B. Jupiter Intra-articular fractures of the distal end of the radius in young adults J Bone Joint Surg 68-A 1986 647-659
    • (1986) J. Bone Joint Surg. , vol.68 A , pp. 647-659
    • Knirk, J.L.1    Jupiter, J.B.2
  • 16
    • 0035073910 scopus 로고    scopus 로고
    • Radiostereometric analysis of distal radial fracture displacement during treatment. A randomized study comparing Norian SRS and external fixation in 23 patients
    • P. Kopylov P. Aspenberg X. Yuan et al. Radiostereometric analysis of distal radial fracture displacement during treatment. A randomized study comparing Norian SRS and external fixation in 23 patients Acta Orthop Scand 72 2001 57-61
    • (2001) Acta Orthop. Scand. , vol.72 , pp. 57-61
    • Kopylov, P.1    Aspenberg, P.2    Yuan, X.3
  • 17
    • 0042736901 scopus 로고    scopus 로고
    • Insertion of tantalum beads in RSA of the hip: Variations in incidence of extra-osseous beads with insertion site
    • D.F. Lawrie M.R. Downing G.P. Ashcroft P.H. Gibson Insertion of tantalum beads in RSA of the hip: Variations in incidence of extra-osseous beads with insertion site Acta Orthop Scand 74 2003 404-407
    • (2003) Acta Orthop. Scand. , vol.74 , pp. 404-407
    • Lawrie, D.F.1    Downing, M.R.2    Ashcroft, G.P.3    Gibson, P.H.4
  • 18
    • 1342304796 scopus 로고    scopus 로고
    • Predictors of early and late instability following conservative treatment of extra-articular distal radius fractures
    • J. Leone M. Bhandari A. Adili et al. Predictors of early and late instability following conservative treatment of extra-articular distal radius fractures Arch Orthop Traum Surg 124 2004 38-41
    • (2004) Arch. Orthop. Traum. Surg. , vol.124 , pp. 38-41
    • Leone, J.1    Bhandari, M.2    Adili, A.3
  • 19
    • 18844467602 scopus 로고    scopus 로고
    • Precision measurements of the RSA method using a phantom model of hip prosthesis
    • T.J. Mäkinen J.K. Koort K.T. Mattila H.T. Aro Precision measurements of the RSA method using a phantom model of hip prosthesis J Biomech 37 2004 487-493
    • (2004) J. Biomech. , vol.37 , pp. 487-493
    • Mäkinen, T.J.1    Koort, J.K.2    Mattila, K.T.3    Aro, H.T.4
  • 20
    • 0142119539 scopus 로고    scopus 로고
    • Stability of internally fixed femoral neck fractures augmented with resorbable cement. A prospective randomized study using radiostereometry
    • P. Mattsson S. Larsson Stability of internally fixed femoral neck fractures augmented with resorbable cement. A prospective randomized study using radiostereometry Scand J Surg 92 2003 215-219
    • (2003) Scand. J. Surg. , vol.92 , pp. 215-219
    • Mattsson, P.1    Larsson, S.2
  • 21
    • 0023792951 scopus 로고
    • Colles fracture: Does the anatomical result affect the final function
    • M. McQueen J. Caspers Colles fracture: Does the anatomical result affect the final function J Bone Joint Surg 70-B 1988 649-651
    • (1988) J. Bone Joint Surg. , vol.70 B , pp. 649-651
    • McQueen, M.1    Caspers, J.2
  • 22
    • 0142023950 scopus 로고    scopus 로고
    • Three-dimensional analysis of the movement of lumbar spinal nerve roots in nonsimulated and simulated adhesive conditions
    • H. Miyamoto G.A. Dumas U.P. Wyss L. Ryd Three-dimensional analysis of the movement of lumbar spinal nerve roots in nonsimulated and simulated adhesive conditions Spine 28 2003 2373-2380
    • (2003) Spine , vol.28 , pp. 2373-2380
    • Miyamoto, H.1    Dumas, G.A.2    Wyss, U.P.3    Ryd, L.4
  • 23
    • 0035215807 scopus 로고    scopus 로고
    • Accuracy and precision of radiostereometric analysis in the measurement of THR femoral component translations: Human and canine in vitro models
    • I. Önsten A. Berzins S. Shott et al. Accuracy and precision of radiostereometric analysis in the measurement of THR femoral component translations: Human and canine in vitro models J Orthop Res 19 2001 1162-1167
    • (2001) J. Orthop. Res. , vol.19 , pp. 1162-1167
    • Önsten, I.1    Berzins, A.2    Shott, S.3
  • 24
    • 0022522401 scopus 로고
    • Micromotion in knee arthroplasty. A Roentgen stereophotogrammetric analysis of tibial component fixation
    • L. Ryd Micromotion in knee arthroplasty. A Roentgen stereophotogrammetric analysis of tibial component fixation Acta Orthop Scand Suppl 220 1986 1-80
    • (1986) Acta Orthop. Scand. Suppl. , vol.220 , pp. 1-80
    • Ryd, L.1
  • 25
    • 0029056371 scopus 로고
    • Roentgen stereophotogrammetric analysis as a predictor of mechanical loosening of knee prostheses
    • L. Ryd B.E. Albrektsson L. Carlsson et al. Roentgen stereophotogrammetric analysis as a predictor of mechanical loosening of knee prostheses J Bone Joint Surg 77-B 1995 377-383
    • (1995) J. Bone Joint Surg. , vol.77 B , pp. 377-383
    • Ryd, L.1    Albrektsson, B.E.2    Carlsson, L.3
  • 26
    • 0024388994 scopus 로고
    • Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system
    • G. Selvik Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system Acta Orthop Scand Suppl 232 1989 1-51
    • (1989) Acta Orthop. Scand. Suppl. , vol.232 , pp. 1-51
    • Selvik, G.1
  • 27
    • 0027897660 scopus 로고
    • Determining the movements of the skeleton using well-configured markers
    • I. Söderkvist P.Å. Wedin Determining the movements of the skeleton using well-configured markers J Biomech 26 1993 1473-1477
    • (1993) J. Biomech. , vol.26 , pp. 1473-1477
    • Söderkvist, I.1    Wedin, P.Å.2
  • 28
    • 0021910913 scopus 로고
    • Factors affecting the outcome of Colles' fracture: An anatomical and functional study
    • H.D. Stewart A.R. Innes F.D. Burke Factors affecting the outcome of Colles' fracture: An anatomical and functional study Injury 16 1985 289-295
    • (1985) Injury , vol.16 , pp. 289-295
    • Stewart, H.D.1    Innes, A.R.2    Burke, F.D.3
  • 29
    • 0036678602 scopus 로고    scopus 로고
    • Migration of the femoral stem after impaction bone grafting. First results of an ongoing, randomised study of the exeter and elite plus femoral stems using radiostereometric analysis
    • W.J. van Doorn H.B. ten F.C. van Biezen et al. Migration of the femoral stem after impaction bone grafting. First results of an ongoing, randomised study of the exeter and elite plus femoral stems using radiostereometric analysis J Bone Joint Surg 84-B 2002 825-831
    • (2002) J. Bone Joint Surg. , vol.84 B , pp. 825-831
    • van Doorn, W.J.1    Ten, H.B.2    van Biezen, F.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.