메뉴 건너뛰기




Volumn 13, Issue 7, 2006, Pages 893-908

Imaging of Small High-Density Structures in CT. A Phantom Study

Author keywords

64 Slice multidetector row computed tomography (CT); blur; phantom experiments; point spread function; size measurement accuracy of small high density objects

Indexed keywords

ALUMINUM;

EID: 33745074057     PISSN: 10766332     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.acra.2006.03.009     Document Type: Article
Times cited : (34)

References (36)
  • 1
    • 9544249488 scopus 로고    scopus 로고
    • Coronary artery calcification: pathophysiology, epidemiology, imaging methods, and clinical implications. A statement for health professionals from the American Heart Association Writing Group
    • Wexler L., Brundage B., Crouse J., et al. Coronary artery calcification: pathophysiology, epidemiology, imaging methods, and clinical implications. A statement for health professionals from the American Heart Association Writing Group. Circulation 94 (1996) 1175-1192
    • (1996) Circulation , vol.94 , pp. 1175-1192
    • Wexler, L.1    Brundage, B.2    Crouse, J.3
  • 2
    • 76549152136 scopus 로고
    • Calcification in the coronary arteries and its relationship to arteriosclerosis and myocardial infarction
    • Beadenkopf W.G., Daoud A.S., and Love B.M. Calcification in the coronary arteries and its relationship to arteriosclerosis and myocardial infarction. AJR Am J Roentgenol Radium Ther Nucl Med 92 (1964) 865-871
    • (1964) AJR Am J Roentgenol Radium Ther Nucl Med , vol.92 , pp. 865-871
    • Beadenkopf, W.G.1    Daoud, A.S.2    Love, B.M.3
  • 3
    • 0842347594 scopus 로고    scopus 로고
    • Restenosis detected by routine angiographic follow-up and late mortality after coronary stent placement
    • Schuhlen H., Kastrati A., Mehilli J., et al. Restenosis detected by routine angiographic follow-up and late mortality after coronary stent placement. Am Heart J 147 (2004) 317-322
    • (2004) Am Heart J , vol.147 , pp. 317-322
    • Schuhlen, H.1    Kastrati, A.2    Mehilli, J.3
  • 4
    • 0344153029 scopus 로고    scopus 로고
    • Evaluation of patients after coronary artery bypass surgery. CT angiographic assessment of grafts and coronary arteries
    • Nieman K., Pattynama P.M., Rensing B.J., et al. Evaluation of patients after coronary artery bypass surgery. CT angiographic assessment of grafts and coronary arteries. Radiology 229 (2003) 749-756
    • (2003) Radiology , vol.229 , pp. 749-756
    • Nieman, K.1    Pattynama, P.M.2    Rensing, B.J.3
  • 5
    • 33745088846 scopus 로고    scopus 로고
    • Kalender WA. Computed tomography: fundamentals, system technology, image quality, applications. In: Publicis MCD, Werbeagentur GmbH, Munich: Verlag, 2000; 4:82-116.
  • 6
    • 0026589081 scopus 로고
    • A definition of the intima of human arteries and of its atherosclerosis-prone regions-a report from the Committee on Vascular-Lesions of the Council on Arteriosclerosis, American-Heart-Association
    • Stary H.C., Blankenhorn D.H., Chandler A.B., et al. A definition of the intima of human arteries and of its atherosclerosis-prone regions-a report from the Committee on Vascular-Lesions of the Council on Arteriosclerosis, American-Heart-Association. Circulation 85 (1992) 391-405
    • (1992) Circulation , vol.85 , pp. 391-405
    • Stary, H.C.1    Blankenhorn, D.H.2    Chandler, A.B.3
  • 7
    • 0028289443 scopus 로고
    • A definition of initial, fatty streak, and intermediate lesions of atherosclerosis. A report from the Committee on Vascular Lesions of the Council on Arteriosclerosis, American Heart Association
    • Stary H.C., Chandler A.B., Glagov S., et al. A definition of initial, fatty streak, and intermediate lesions of atherosclerosis. A report from the Committee on Vascular Lesions of the Council on Arteriosclerosis, American Heart Association. Circulation 89 (1994) 2462-2478
    • (1994) Circulation , vol.89 , pp. 2462-2478
    • Stary, H.C.1    Chandler, A.B.2    Glagov, S.3
  • 8
    • 0029097154 scopus 로고
    • A definition of advanced types of atherosclerotic lesions and a histological classification of atherosclerosis-a report from the Committee on Vascular-Lesions of the Council on Arteriosclerosis, American-Heart-Association
    • Stary H.C., Chandler A.B., Dinsmore R.E., et al. A definition of advanced types of atherosclerotic lesions and a histological classification of atherosclerosis-a report from the Committee on Vascular-Lesions of the Council on Arteriosclerosis, American-Heart-Association. Circulation 92 (1995) 1355-1374
    • (1995) Circulation , vol.92 , pp. 1355-1374
    • Stary, H.C.1    Chandler, A.B.2    Dinsmore, R.E.3
  • 9
    • 23844500695 scopus 로고    scopus 로고
    • Improving the imaging of calcifications in CT by histogram-based selective deblurring
    • In Conference Proceedings, SPIE, Med Imaging 2005
    • Rollano-Hijarrubia E., van der Meer F., van der Lugt A., et al. Improving the imaging of calcifications in CT by histogram-based selective deblurring. Physics of Medical Imaging 5745 (2005) 67-78 In Conference Proceedings, SPIE, Med Imaging 2005
    • (2005) Physics of Medical Imaging , vol.5745 , pp. 67-78
    • Rollano-Hijarrubia, E.1    van der Meer, F.2    van der Lugt, A.3
  • 11
    • 0035043381 scopus 로고    scopus 로고
    • Endoluminal treatment of internal carotid artery stenosis
    • Mathias K., Jager H., Hennigs S., et al. Endoluminal treatment of internal carotid artery stenosis. World J Surg 25 (2001) 328-334
    • (2001) World J Surg , vol.25 , pp. 328-334
    • Mathias, K.1    Jager, H.2    Hennigs, S.3
  • 13
    • 0031146681 scopus 로고    scopus 로고
    • The use of deblurring technique for improving the longitudinal resolution in helical CT of the head and neck region
    • Sakai O., Shen Y., Takata Y., et al. The use of deblurring technique for improving the longitudinal resolution in helical CT of the head and neck region. Comput Med Imaging Graphics 21 (1997) 153-164
    • (1997) Comput Med Imaging Graphics , vol.21 , pp. 153-164
    • Sakai, O.1    Shen, Y.2    Takata, Y.3
  • 14
    • 0036242437 scopus 로고    scopus 로고
    • Coronary artery calcium. absolute quantification in nonenhanced and contrast-enhanced multi-detector row CT studies
    • Hong C., Becker C.R., Schoepf U.J., et al. Coronary artery calcium. absolute quantification in nonenhanced and contrast-enhanced multi-detector row CT studies. Radiology 223 (2002) 474-480
    • (2002) Radiology , vol.223 , pp. 474-480
    • Hong, C.1    Becker, C.R.2    Schoepf, U.J.3
  • 15
    • 10644277990 scopus 로고    scopus 로고
    • Calcified coronary artery plaque measurement with cardiac CT in population-based studies. standardized protocol of Multi-Ethnic Study of Atherosclerosis (MESA) and Coronary Artery Risk Development in Young Adults (CARDIA) study
    • Carr J.J., Nelson J.C., Wong N.D., et al. Calcified coronary artery plaque measurement with cardiac CT in population-based studies. standardized protocol of Multi-Ethnic Study of Atherosclerosis (MESA) and Coronary Artery Risk Development in Young Adults (CARDIA) study. Radiology 234 (2005) 35-43
    • (2005) Radiology , vol.234 , pp. 35-43
    • Carr, J.J.1    Nelson, J.C.2    Wong, N.D.3
  • 16
    • 0034040590 scopus 로고    scopus 로고
    • Visualization and quantification of coronary calcifications with electron beam and spiral computed tomography
    • Becker C.R., Knez A., Ohnesorge B., et al. Visualization and quantification of coronary calcifications with electron beam and spiral computed tomography. Eur Radiol 10 (2000) 629-635
    • (2000) Eur Radiol , vol.10 , pp. 629-635
    • Becker, C.R.1    Knez, A.2    Ohnesorge, B.3
  • 17
    • 0037903112 scopus 로고    scopus 로고
    • Assessment of calcium scoring performance in cardiac computed tomography
    • Ulzheimer S., and Kalender W.A. Assessment of calcium scoring performance in cardiac computed tomography. Eur Radiol 13 (2003) 484-497
    • (2003) Eur Radiol , vol.13 , pp. 484-497
    • Ulzheimer, S.1    Kalender, W.A.2
  • 18
    • 0031929482 scopus 로고    scopus 로고
    • Limitations of clinical CT in assessing cortical thickness and density
    • Newman D.L., Dougherty G., al Obaid A., et al. Limitations of clinical CT in assessing cortical thickness and density. Phys Med Biol 43 (1998) 619-626
    • (1998) Phys Med Biol , vol.43 , pp. 619-626
    • Newman, D.L.1    Dougherty, G.2    al Obaid, A.3
  • 19
    • 0032998150 scopus 로고    scopus 로고
    • Accuracy limits for the determination of cortical width and density. the influence of object size and CT imaging parameters
    • Prevrhal S., Engelke K., and Kalender W.A. Accuracy limits for the determination of cortical width and density. the influence of object size and CT imaging parameters. Phys Med Biol 44 (1999) 751-764
    • (1999) Phys Med Biol , vol.44 , pp. 751-764
    • Prevrhal, S.1    Engelke, K.2    Kalender, W.A.3
  • 20
    • 12244308527 scopus 로고    scopus 로고
    • Accuracy of CT-based thickness measurement of thin structures. modeling of limited spatial resolution in all three dimensions
    • Prevrhal S., Fox J.C., Shepherd J.A., et al. Accuracy of CT-based thickness measurement of thin structures. modeling of limited spatial resolution in all three dimensions. Med Phys 30 (2003) 1-8
    • (2003) Med Phys , vol.30 , pp. 1-8
    • Prevrhal, S.1    Fox, J.C.2    Shepherd, J.A.3
  • 21
    • 0014557223 scopus 로고
    • Point spread-function, line spread-function, and modulation transfer function. Tools for the study of imaging systems
    • Rossmann K. Point spread-function, line spread-function, and modulation transfer function. Tools for the study of imaging systems. Radiology 93 (1969) 257-272
    • (1969) Radiology , vol.93 , pp. 257-272
    • Rossmann, K.1
  • 22
    • 0038350968 scopus 로고    scopus 로고
    • Spatial variation of resolution and noise in multi-detector row spiral CT
    • Meinel Jr. J.F., Wang G., Jiang M., et al. Spatial variation of resolution and noise in multi-detector row spiral CT. Acad Radiol 10 (2003) 607-613
    • (2003) Acad Radiol , vol.10 , pp. 607-613
    • Meinel Jr., J.F.1    Wang, G.2    Jiang, M.3
  • 23
    • 0025455491 scopus 로고
    • Objective assessment of image quality. effects of quantum noise and object variability
    • Barrett H.H. Objective assessment of image quality. effects of quantum noise and object variability. J Opt Soc Am A 7 (1990) 1266-1278
    • (1990) J Opt Soc Am A , vol.7 , pp. 1266-1278
    • Barrett, H.H.1
  • 24
    • 0030796287 scopus 로고    scopus 로고
    • A phantom for evaluating bone mineral density of the hand by dual-energy x-ray absorptiometry
    • Steel S.A., Swann P., Langley G., et al. A phantom for evaluating bone mineral density of the hand by dual-energy x-ray absorptiometry. Physiol Meas 18 (1997) 233-240
    • (1997) Physiol Meas , vol.18 , pp. 233-240
    • Steel, S.A.1    Swann, P.2    Langley, G.3
  • 25
    • 0032862526 scopus 로고    scopus 로고
    • Digital radiography-a predictor of regenerate bone stiffness in distraction osteogenesis
    • Kolbeck S., Bail H., Weiler A., et al. Digital radiography-a predictor of regenerate bone stiffness in distraction osteogenesis. Clin Orthop 366 (1999) 221-228
    • (1999) Clin Orthop , vol.366 , pp. 221-228
    • Kolbeck, S.1    Bail, H.2    Weiler, A.3
  • 26
    • 14944354811 scopus 로고    scopus 로고
    • Advances in cardiac CT imaging. 64-slice scanner
    • Nikolaou K., Flohr T., Knez A., et al. Advances in cardiac CT imaging. 64-slice scanner. Int J Cardiovasc Imaging 20 (2004) 535-540
    • (2004) Int J Cardiovasc Imaging , vol.20 , pp. 535-540
    • Nikolaou, K.1    Flohr, T.2    Knez, A.3
  • 27
    • 0037743486 scopus 로고    scopus 로고
    • Spatial domain image filtering in computed tomography. feasibility study in pulmonary embolism
    • Wildberger J.E., Mahnken A.H., Flohr T., et al. Spatial domain image filtering in computed tomography. feasibility study in pulmonary embolism. Eur Radiol 13 (2003) 717-723
    • (2003) Eur Radiol , vol.13 , pp. 717-723
    • Wildberger, J.E.1    Mahnken, A.H.2    Flohr, T.3
  • 28
    • 0034839393 scopus 로고    scopus 로고
    • Fast image filters as an alternative approach to reconstruction kernel in computed tomography
    • Proceedings of SPIE: medical imaging 2001, image processing
    • Flohr T., Schaller S., Stadler A., et al. Fast image filters as an alternative approach to reconstruction kernel in computed tomography. Proceedings of SPIE: medical imaging 2001, image processing. Int Soc Optic Eng 4322 (2001) 924-933
    • (2001) Int Soc Optic Eng , vol.4322 , pp. 924-933
    • Flohr, T.1    Schaller, S.2    Stadler, A.3
  • 29
    • 0041525252 scopus 로고    scopus 로고
    • Spatial domain filtering for fast modification of the tradeoff between image sharpness and pixel noise in computed tomography
    • Schaller S., Wildberger J.E., Raupach R., et al. Spatial domain filtering for fast modification of the tradeoff between image sharpness and pixel noise in computed tomography. IEEE Trans Med Imaging 22 (2003) 846-853
    • (2003) IEEE Trans Med Imaging , vol.22 , pp. 846-853
    • Schaller, S.1    Wildberger, J.E.2    Raupach, R.3
  • 30
    • 0032924568 scopus 로고    scopus 로고
    • Multi-slice helical CT. scan and reconstruction
    • Hu H. Multi-slice helical CT. scan and reconstruction. Med Phys 26 (1999) 5-18
    • (1999) Med Phys , vol.26 , pp. 5-18
    • Hu, H.1
  • 31
    • 0027955501 scopus 로고
    • Measurement of slice sensitivity profiles in spiral CT
    • Polacin A., Kalender W.A., Brink J., et al. Measurement of slice sensitivity profiles in spiral CT. Med Phys 21 (1994) 133-140
    • (1994) Med Phys , vol.21 , pp. 133-140
    • Polacin, A.1    Kalender, W.A.2    Brink, J.3
  • 32
    • 0026712389 scopus 로고
    • Evaluation of section sensitivity profiles and image noise in spiral CT
    • Polacin A., Kalender W.A., and Marchal G. Evaluation of section sensitivity profiles and image noise in spiral CT. Radiology 185 (1992) 29-35
    • (1992) Radiology , vol.185 , pp. 29-35
    • Polacin, A.1    Kalender, W.A.2    Marchal, G.3
  • 33
    • 0032718470 scopus 로고    scopus 로고
    • Performance evaluation of a multi-slice CT system
    • McCollough C.H., and Zink F.E. Performance evaluation of a multi-slice CT system. Med Phys 26 (1999) 2223-2230
    • (1999) Med Phys , vol.26 , pp. 2223-2230
    • McCollough, C.H.1    Zink, F.E.2
  • 34
    • 0033452893 scopus 로고    scopus 로고
    • The effect of pitch in multislice spiral/helical CT
    • Wang G., and Vannier M.W. The effect of pitch in multislice spiral/helical CT. Med Phys 26 (1999) 2648-2653
    • (1999) Med Phys , vol.26 , pp. 2648-2653
    • Wang, G.1    Vannier, M.W.2
  • 35
    • 0018411844 scopus 로고
    • Theoretical resolution of computed tomography systems
    • Glover G.H., and Eisner R.L. Theoretical resolution of computed tomography systems. J Comput Assist Tomogr 3 (1979) 85-91
    • (1979) J Comput Assist Tomogr , vol.3 , pp. 85-91
    • Glover, G.H.1    Eisner, R.L.2
  • 36
    • 0027944090 scopus 로고
    • Longitudinal image deblurring in spiral CT
    • Schlueter F.J., Wang G., Hsieh P.S., et al. Longitudinal image deblurring in spiral CT. Radiology 193 (1994) 413-418
    • (1994) Radiology , vol.193 , pp. 413-418
    • Schlueter, F.J.1    Wang, G.2    Hsieh, P.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.