-
1
-
-
9544249488
-
Coronary artery calcification: Pathophysiology, epidemiology, imaging methods, and clinical implications. A statement for health professionals from the American Heart Association
-
L. Wexler et al., "Coronary Artery Calcification: Pathophysiology, Epidemiology, Imaging Methods, and Clinical Implications. A Statement for Health Professionals from the American Heart Association", Circulation, 94, 1175-1192, 1996.
-
(1996)
Circulation
, vol.94
, pp. 1175-1192
-
-
Wexler, L.1
-
2
-
-
0026589081
-
A definition of the intima of human arteries and of its atherosclerosis-prone regions: A report from the Committee on Vascular Lesions of the Council on Arteriosclerosis, American Heart Association. Special report
-
H. Stary et al., "A definition of the intima of human arteries and of its atherosclerosis-prone regions: a report from the Committee on Vascular Lesions of the Council on Arteriosclerosis, American Heart Association. Special report", Circulation, 85, 391-405, 1992.
-
(1992)
Circulation
, vol.85
, pp. 391-405
-
-
Stary, H.1
-
3
-
-
0028208606
-
A definition of initial, fatty streak, and intermediate lesions of atherosclerosis: A report from the Committee on Vascular Lesions of the Council on Arteriosclerosis, American Heart Association. Special report
-
H. Stary et al., "A definition of initial, fatty streak, and intermediate lesions of atherosclerosis: a report from the Committee on Vascular Lesions of the Council on Arteriosclerosis, American Heart Association. Special report", Arteriosclerosis Thrombosis and Vascular Biology, 14, 840-856, 1994.
-
(1994)
Arteriosclerosis Thrombosis and Vascular Biology
, vol.14
, pp. 840-856
-
-
Stary, H.1
-
4
-
-
0029097154
-
A definition of advanced types of atherosclerotic lesions and a histological classification of atherosclerosis
-
C. Herbert et al., "A Definition of Advanced Types of Atherosclerotic Lesions and a Histological Classification of Atherosclerosis",Circulation, 92, 1355-1374, 1995.
-
(1995)
Circulation
, vol.92
, pp. 1355-1374
-
-
Herbert, C.1
-
5
-
-
0028019566
-
Ultrafast computed tomography-detected coronary calcium reflects the angiographic extent of coronary arterial atherosclerosis
-
A. Agatston et al., "Ultrafast computed tomography-detected coronary calcium reflects the angiographic extent of coronary arterial atherosclerosis", American Journal of Cardiology, 74, 1272-4, 1994.
-
(1994)
American Journal of Cardiology
, vol.74
, pp. 1272-1274
-
-
Agatston, A.1
-
6
-
-
0034311878
-
Current development of cardiac imaging with multidetectorrow CT
-
C. Becker, B.M. Ohnesorge, U.J. Schoepf, M.F. Reiser, "Current development of cardiac imaging with multidetectorrow CT", European Journal of Radiology, 36, 97-103, 2000.
-
(2000)
European Journal of Radiology
, vol.36
, pp. 97-103
-
-
Becker, C.1
Ohnesorge, B.M.2
Schoepf, U.J.3
Reiser, M.F.4
-
7
-
-
0004234405
-
-
chapter 4, Publicis MCD Verlag, Munich
-
W. Kalender, Computed Tomography, chapter 4, Publicis MCD Verlag, Munich, 2000.
-
(2000)
Computed Tomography
-
-
Kalender, W.1
-
8
-
-
0027944090
-
Longitudinal image deblurring in spiral CT
-
F. Schlueter et al., "Longitudinal image deblurring in spiral CT", Radiology, 193, 413-418, 1994.
-
(1994)
Radiology
, vol.193
, pp. 413-418
-
-
Schlueter, F.1
-
9
-
-
0029380602
-
Temporal bone volumetric image deblurring in spiral computed tomography scanning
-
G. Wang, M. Skinner, M. Vannier, "Temporal bone volumetric image deblurring in spiral computed tomography scanning", Academic Radiology, 2, 888-895, 1995.
-
(1995)
Academic Radiology
, vol.2
, pp. 888-895
-
-
Wang, G.1
Skinner, M.2
Vannier, M.3
-
10
-
-
0032034231
-
Spiral CT image deblurring for cochlear implantation
-
G. Wang et al., "Spiral CT image deblurring for cochlear implantation", IEEE Transactions on Medical Imaging, 17, 251-262, 1998.
-
(1998)
IEEE Transactions on Medical Imaging
, vol.17
, pp. 251-262
-
-
Wang, G.1
-
11
-
-
12244308527
-
Accuracy of CT-based thickness measurement of thin structures: Modeling of limited spatial resolution in all three dimensions
-
S. Prevrhal, J. Fox, J. Shepherd, H. Genant, "Accuracy of CT-based thickness measurement of thin structures: Modeling of limited spatial resolution in all three dimensions", Medical Physics, 30, 1-8, 2003.
-
(2003)
Medical Physics
, vol.30
, pp. 1-8
-
-
Prevrhal, S.1
Fox, J.2
Shepherd, J.3
Genant, H.4
-
12
-
-
0038119671
-
Coronary calcium scoring: Modelling, predicting and correcting for the effect of CT scanner spatial resolution on Agatston and volume scores
-
L. Kaufman et al., "Coronary calcium scoring: modelling, predicting and correcting for the effect of CT scanner spatial resolution on Agatston and volume scores", Physics In Medicine And Biology, 48, 1423-1436, 2003.
-
(2003)
Physics in Medicine and Biology
, vol.48
, pp. 1423-1436
-
-
Kaufman, L.1
-
13
-
-
13244260603
-
-
Chapter 5, Pearson Prentice-Hall, New Jersey
-
R. Gonzalez, R. Woods, Digital Imaging Processing, Chapter 5, Pearson Prentice-Hall, New Jersey, 2003.
-
(2003)
Digital Imaging Processing
-
-
Gonzalez, R.1
Woods, R.2
-
14
-
-
0031146681
-
The use of deblurring technique for improving the longitudinal resolution in helical CT of the head and neck region
-
O. Sakai, Y. Shen, Y. Takata, Furuse, "The use of deblurring technique for improving the longitudinal resolution in helical CT of the head and neck region", Computarized Medical Imaging and Graphics, 21, 153-164, 1997.
-
(1997)
Computarized Medical Imaging and Graphics
, vol.21
, pp. 153-164
-
-
Sakai, O.1
Shen, Y.2
Takata, Y.3
Furuse4
-
15
-
-
0018411844
-
Theoretical resolution of computed tomography systems
-
G. Glover, R. Eisner, "Theoretical Resolution of Computed Tomography Systems", Journal of Computer Assisted Tomography, 3, 85-91, 1979.
-
(1979)
Journal of Computer Assisted Tomography
, vol.3
, pp. 85-91
-
-
Glover, G.1
Eisner, R.2
-
16
-
-
2442684227
-
Atherosclerotic lesions at microCT: Feasibility for analysis of coronary artery wall in autopsy specimens
-
A. Langheinrich, "Atherosclerotic Lesions at microCT: Feasibility for Analysis of Coronary Artery Wall in Autopsy Specimens", Radiology, 231, 675-681, 2004.
-
(2004)
Radiology
, vol.231
, pp. 675-681
-
-
Langheinrich, A.1
-
17
-
-
1242316313
-
MicroCT scanner performance and considerations for vascular specimen imaging
-
M. Marxen et al., "MicroCT scanner performance and considerations for vascular specimen imaging", Medical Physics, 31, 305-13, 2004.
-
(2004)
Medical Physics
, vol.31
, pp. 305-313
-
-
Marxen, M.1
-
18
-
-
0034503420
-
Relationship between ultrasound texture classification images and histology of atherosclerotic plaque
-
F. Rakebrandt, et al., "Relationship between ultrasound texture classification images and histology of atherosclerotic plaque", Ultrasound in Medicine and Biology, 26, 1393-402, 2000.
-
(2000)
Ultrasound in Medicine and Biology
, vol.26
, pp. 1393-1402
-
-
Rakebrandt, F.1
-
19
-
-
0038350968
-
Spatial variation of resolution and noise in multi-detector row spiral CT
-
J. Meinel et al., "Spatial Variation of Resolution and Noise in Multi-Detector Row Spiral CT", Academic Radiology, 10, 607-613, 2003.
-
(2003)
Academic Radiology
, vol.10
, pp. 607-613
-
-
Meinel, J.1
-
20
-
-
0023983801
-
A comparison of deconvolution and windowed subtraction techniques for scatter compensation in SPECT
-
J. Yanch, M. Flower, S. Webb, "A comparison of deconvolution and windowed subtraction techniques for scatter compensation in SPECT", IEEE Transactions on Medical Imaging, 7, 13-20, 1988.
-
(1988)
IEEE Transactions on Medical Imaging
, vol.7
, pp. 13-20
-
-
Yanch, J.1
Flower, M.2
Webb, S.3
-
21
-
-
0031293487
-
Experimental determination of CT point spread function anisotropy and shift-variance
-
EMBS, Chicago
-
D. Sylvie, G. Yves, "Experimental determination of CT point spread function anisotropy and shift-variance", 19th International Conference - IEEE, EMBS, 788-791, Chicago, 1997.
-
(1997)
19th International Conference - IEEE
, pp. 788-791
-
-
Sylvie, D.1
Yves, G.2
-
22
-
-
0035999414
-
Blind deblurring of spiral CT images-comparative studies on edge-to-noise ratios
-
M. Jiang et al., "Blind deblurring of spiral CT images-comparative studies on edge-to-noise ratios", Medical Physics, 29, 821-9, 2002.
-
(2002)
Medical Physics
, vol.29
, pp. 821-829
-
-
Jiang, M.1
-
23
-
-
0042527121
-
Blind deblurring of spiral CT images
-
Jiang et al., "Blind deblurring of spiral CT images", IEEE Transactions on Medical Imaging, 22, 837-45, 2003.
-
(2003)
IEEE Transactions on Medical Imaging
, vol.22
, pp. 837-845
-
-
Jiang1
-
24
-
-
0032998150
-
Accuracy limits for the determination of cortical width and density: The influence of object size and CT imaging parameters
-
S. Prevrhal, K. Engelke, W. Kalender, "Accuracy limits for the determination of cortical width and density: the influence of object size and CT imaging parameters", Physics in Medicine and Biology, 44, 751-764, 1999.
-
(1999)
Physics in Medicine and Biology
, vol.44
, pp. 751-764
-
-
Prevrhal, S.1
Engelke, K.2
Kalender, W.3
-
25
-
-
0041421080
-
Maximizing quantitative accuracy of lung airway lumen and wall measures obtained from X-ray CT imaging
-
O. Saba, E. Hoffrnan, J. Reinhardt, "Maximizing quantitative accuracy of lung airway lumen and wall measures obtained from X-ray CT imaging", Journal of Applied Physiology, 95, 1063-1075, 2003.
-
(2003)
Journal of Applied Physiology
, vol.95
, pp. 1063-1075
-
-
Saba, O.1
Hoffrnan, E.2
Reinhardt, J.3
|