Volumn 15, Issue 2, 2006, Pages 196-205

Clinical comparison of automatic, noninvasive measurements of blood pressure in the forearm and upper arm with the patient supine or with the head of the bed raised 45°: A follow-up study

Author keywords

[No Author keywords available]

Indexed keywords

ADOLESCENT; ADULT; ARM; ARTICLE; BLOOD PRESSURE MEASUREMENT; BODY POSTURE; COMPARATIVE STUDY; FEMALE; FOREARM; HUMAN; MALE; METHODOLOGY; SUPINE POSITION;

EID: 33745027907     PISSN: 10623264     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (19)

References (17)
  • 1
    • 19944429836 scopus 로고    scopus 로고
    • Recommendations for blood pressure measurement in humans and experimental animals, 1: Blood pressure measurement in humans: A statement for professionals from the Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research
    • Pickering TG, Hall JE, Appel LJ, et al. Recommendations for blood pressure measurement in humans and experimental animals, 1: blood pressure measurement in humans: a statement for professionals from the Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research. Hypertension. 2005;45:142-161.
    • (2005) Hypertension , vol.45 , pp. 142-161
    • Pickering, T.G.1    Hall, J.E.2    Appel, L.J.3
  • 3
    • 0035799041 scopus 로고    scopus 로고
    • Blood pressure measuring devices: Recommendations of the European Society of Hypertension
    • Brien E, Waeber B, Parati G, Staessen J, Myers MG. Blood pressure measuring devices: recommendations of the European Society of Hypertension. BMJ. 2001;322:531-536.
    • (2001) BMJ , vol.322 , pp. 531-536
    • Brien, E.1    Waeber, B.2    Parati, G.3    Staessen, J.4    Myers, M.G.5
  • 4
    • 1842418717 scopus 로고    scopus 로고
    • Measuring blood pressure: Pitfalls and recommendations
    • Tholl T, Forstner K, Anlauf M. Measuring blood pressure: pitfalls and recommendations. Nephrol Dial Transplant. 2004;19:766-770.
    • (2004) Nephrol Dial Transplant , vol.19 , pp. 766-770
    • Tholl, T.1    Forstner, K.2    Anlauf, M.3
  • 5
    • 0038314757 scopus 로고    scopus 로고
    • Joint National Committee on Detection, Evaluation, and Treatment of High Blood Pressure. Bethesda, Md: National Institutes of Health. NIH publication No. 04-5230
    • Joint National Committee on Detection, Evaluation, and Treatment of High Blood Pressure. The Seventh Report of the Joint National Committee on Detection, Evaluation, and Treatment of High Blood Pressure. Bethesda, Md: National Institutes of Health; 2004. NIH publication No. 04-5230.
    • (2004) The Seventh Report of the Joint National Committee on Detection, Evaluation, and Treatment of High Blood Pressure
  • 6
    • 0003770531 scopus 로고    scopus 로고
    • American Heart Association. Dallas, Tex: American Heart Association
    • American Heart Association. ACLS Provider Manual. Dallas, Tex: American Heart Association; 2001.
    • (2001) ACLS Provider Manual
  • 9
    • 21044451418 scopus 로고    scopus 로고
    • Clinical comparison of automatic, noninvasive measurements of blood pressure in the forearm and upper arm
    • Schell K, Bradley E, Bucher L, et al. Clinical comparison of automatic, noninvasive measurements of blood pressure in the forearm and upper arm. Am J Crit Care. 2005;14:232-241.
    • (2005) Am J Crit Care , vol.14 , pp. 232-241
    • Schell, K.1    Bradley, E.2    Bucher, L.3
  • 10
    • 0031046988 scopus 로고    scopus 로고
    • Evaluation of instruments for noninvasive blood pressure monitoring of the wrist
    • Latman NS, Latman A. Evaluation of instruments for noninvasive blood pressure monitoring of the wrist. Biomed Instrum Technol. 1997;31:63-68.
    • (1997) Biomed Instrum Technol , vol.31 , pp. 63-68
    • Latman, N.S.1    Latman, A.2
  • 11
    • 0036174594 scopus 로고    scopus 로고
    • An evaluation of non-invasive blood pressure (NIBP) monitoring on the wrist: Comparison with upper arm NIBP measurement
    • Emerick DR. An evaluation of non-invasive blood pressure (NIBP) monitoring on the wrist: comparison with upper arm NIBP measurement. Anaesth Intensive Care. 2002;30:43-47.
    • (2002) Anaesth Intensive Care , vol.30 , pp. 43-47
    • Emerick, D.R.1
  • 12
    • 0037331564 scopus 로고    scopus 로고
    • Influence of body and arm position on blood pressure readings: An overview
    • Netea RT, Lenders J, Smits P, Thien T. Influence of body and arm position on blood pressure readings: an overview. J Hypertens. 2003;21:237-241.
    • (2003) J Hypertens , vol.21 , pp. 237-241
    • Netea, R.T.1    Lenders, J.2    Smits, P.3    Thien, T.4
  • 15
    • 84908219488 scopus 로고
    • Statistical methods for assessing between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing between two methods of clinical measurement. Lancet. 1986;1:307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 16
    • 0028361238 scopus 로고
    • Epidemiological perspective of body position and arm level in blood pressure measurement
    • Terent A, Breig-Asberg E. Epidemiological perspective of body position and arm level in blood pressure measurement. Blood Press. 1994;3:156-163.
    • (1994) Blood Press , vol.3 , pp. 156-163
    • Terent, A.1    Breig-Asberg, E.2
  • 17
    • 0036097430 scopus 로고    scopus 로고
    • Body position and blood pressure measurement in patients with diabetes mellitus
    • Netea RT, Elving LD, Lutterman JA, Thien T. Body position and blood pressure measurement in patients with diabetes mellitus. J Intern Med. 2002;251:393-399.
    • (2002) J Intern Med , vol.251 , pp. 393-399
    • Netea, R.T.1    Elving, L.D.2    Lutterman, J.A.3    Thien, T.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.