메뉴 건너뛰기




Volumn 55, Issue 6, 2006, Pages 1454-1459

Active catheter tracking using parallel MRI and real-time image reconstruction

Author keywords

Active device tracking; Cardiac MRI; Interactive real time parallel MRI; Interventional MRI; Intravascular catheters

Indexed keywords

CATHETERS; MAGNETIC RESONANCE IMAGING;

EID: 33744962432     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.20902     Document Type: Article
Times cited : (44)

References (20)
  • 1
    • 0343953777 scopus 로고    scopus 로고
    • Susceptibility-based catheter visualization
    • Debatin JF, Adam G, editors. Berlin: Springer
    • Smits HFM, Bakker CJG. Susceptibility-based catheter visualization. In: Debatin JF, Adam G, editors. Interventional magnetic resonance imaging. Berlin: Springer; 1999. p 51-55.
    • (1999) Interventional Magnetic Resonance Imaging , pp. 51-55
    • Smits, H.F.M.1    Bakker, C.J.G.2
  • 4
    • 4243959720 scopus 로고    scopus 로고
    • MR-visible coated devices: In vitro and in vivo evaluation
    • Unal O, Li J, Yu H, Strother CM. MR-visible coated devices: in vitro and in vivo evaluation. Eur Radiol 2002;12:F12.
    • (2002) Eur Radiol , vol.12
    • Unal, O.1    Li, J.2    Yu, H.3    Strother, C.M.4
  • 5
    • 0002743404 scopus 로고    scopus 로고
    • Field inhomogeneity-based catheter visualization
    • Debatin JF, Adam G, editors. Berlin: Springer
    • Glowinski A. Field inhomogeneity-based catheter visualization. In: Debatin JF, Adam G, editors. Interventional magnetic resonance imaging. Berlin: Springer; 1999. p 56-63.
    • (1999) Interventional Magnetic Resonance Imaging , pp. 56-63
    • Glowinski, A.1
  • 6
    • 0029781333 scopus 로고    scopus 로고
    • Tuned fiducial markers to identify body locations with minimal pertubation of tissue magnetization
    • Burl M, Goutts GA, Young IR. Tuned fiducial markers to identify body locations with minimal pertubation of tissue magnetization. Magn Reson Med 1996;36:491-493.
    • (1996) Magn Reson Med , vol.36 , pp. 491-493
    • Burl, M.1    Goutts, G.A.2    Young, I.R.3
  • 7
    • 0027399141 scopus 로고
    • Real-time position monitoring of invasive devices using magnetic resonance
    • Dumoulin CL, Souza SP, Darrow RD. Real-time position monitoring of invasive devices using magnetic resonance. Magn Reson Med 1993:29: 411-415.
    • (1993) Magn Reson Med , vol.29 , pp. 411-415
    • Dumoulin, C.L.1    Souza, S.P.2    Darrow, R.D.3
  • 9
    • 2442547244 scopus 로고    scopus 로고
    • MR-guided intravascular procedures: Real-time parameter control and automated slice positioning with active tracking coils
    • Bock M, Volz S, Zuhlsdorff S, Umathum R, Fink C, Hallscheidt P, Semmler W. MR-guided intravascular procedures: real-time parameter control and automated slice positioning with active tracking coils. J Magn Reson Imaging 2004;19:580-589.
    • (2004) J Magn Reson Imaging , vol.19 , pp. 580-589
    • Bock, M.1    Volz, S.2    Zuhlsdorff, S.3    Umathum, R.4    Fink, C.5    Hallscheidt, P.6    Semmler, W.7
  • 10
    • 0942265565 scopus 로고    scopus 로고
    • Renal embolization: Feasibility of magnetic resonance-guidance using active catheter tracking and intraarterial magnetic resonance angiography
    • Fink C, Bock M, Umathum R, Volz S, Zuehlsdorff S, Grobholz R, Kauczor HU, Hallscheidt P. Renal embolization: feasibility of magnetic resonance-guidance using active catheter tracking and intraarterial magnetic resonance angiography. Invest Radiol 2004;39:111-119.
    • (2004) Invest Radiol , vol.39 , pp. 111-119
    • Fink, C.1    Bock, M.2    Umathum, R.3    Volz, S.4    Zuehlsdorff, S.5    Grobholz, R.6    Kauczor, H.U.7    Hallscheidt, P.8
  • 12
    • 0242385483 scopus 로고    scopus 로고
    • K-t BLAST and k-t SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlations
    • Tsao J, Boesiger P, Pruessmann KP. k-t BLAST and k-t SENSE: dynamic MRI with high frame rate exploiting spatiotemporal correlations. Magn Reson Med 2003;50:1031-1042.
    • (2003) Magn Reson Med , vol.50 , pp. 1031-1042
    • Tsao, J.1    Boesiger, P.2    Pruessmann, K.P.3
  • 13
    • 0030982409 scopus 로고    scopus 로고
    • Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
    • Sodicksen D, Manning WJ. Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays. Magn Reson Med 1997;38:591-603.
    • (1997) Magn Reson Med , vol.38 , pp. 591-603
    • Sodicksen, D.1    Manning, W.J.2
  • 16
    • 11144343722 scopus 로고    scopus 로고
    • Time-resolved contrast-enhanced three-dimensional magnetic resonance angiography of the chest: Combination of parallel imaging with view sharing (TREAT)
    • Fink C, Ley S, Kroeker R, Requardt M, Kauczor HU, Bock M. Time-resolved contrast-enhanced three-dimensional magnetic resonance angiography of the chest: combination of parallel imaging with view sharing (TREAT). Invest Radiol 2005;40:40-48.
    • (2005) Invest Radiol , vol.40 , pp. 40-48
    • Fink, C.1    Ley, S.2    Kroeker, R.3    Requardt, M.4    Kauczor, H.U.5    Bock, M.6
  • 17
    • 16444385871 scopus 로고    scopus 로고
    • Dynamic autocalibrated parallel imaging using temporal GRAPPA (TGRAPPA)
    • Breuer FA, Kellman P, Griswold MA, Jakob PM. Dynamic autocalibrated parallel imaging using temporal GRAPPA (TGRAPPA). Magn Reson Med 2005;53:981-985.
    • (2005) Magn Reson Med , vol.53 , pp. 981-985
    • Breuer, F.A.1    Kellman, P.2    Griswold, M.A.3    Jakob, P.M.4
  • 18
    • 0035032781 scopus 로고    scopus 로고
    • Adaptive sensitivity encoding incorporating temporal filtering (TSENSE)
    • Kellman P, Epstein FH, McVeigh ER. Adaptive sensitivity encoding incorporating temporal filtering (TSENSE). Magn Reson Med 2001;45: 846-852.
    • (2001) Magn Reson Med , vol.45 , pp. 846-852
    • Kellman, P.1    Epstein, F.H.2    McVeigh, E.R.3
  • 20
    • 33744965467 scopus 로고    scopus 로고
    • Why less can be more: A dynamic coil selection algorithm for real-time interactive MRI
    • Miami Beach, FL, USA
    • Müller S, Bock M, Semmler W. Why less can be more: a dynamic coil selection algorithm for real-time interactive MRI. In: Proceedings of the 13th Annual Meeting of ISMRM, Miami Beach, FL, USA, 2005. p 2417.
    • (2005) Proceedings of the 13th Annual Meeting of ISMRM , pp. 2417
    • Müller, S.1    Bock, M.2    Semmler, W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.