메뉴 건너뛰기




Volumn 3749 LNCS, Issue , 2005, Pages 605-612

Self-calibrating ultrasound-to-CT bone registration

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHMS; COMPUTERIZED TOMOGRAPHY; DATA ACQUISITION; PATIENT TREATMENT; THREE DIMENSIONAL; ULTRASONICS;

EID: 33744796835     PISSN: 03029743     EISSN: 16113349     Source Type: Book Series    
DOI: 10.1007/11566465_75     Document Type: Conference Paper
Times cited : (8)

References (11)
  • 1
    • 0002375327 scopus 로고    scopus 로고
    • Computer-assisted spinal surgery using anatomy-based registration
    • Computer Taylor, R.H., Lavallée, S., Burdea, G.C., Mösges, R. (eds): MIT Press, Cambridge MA
    • Lavallée, S., Troccaz, J., et al.: Computer-assisted spinal surgery using anatomy-based registration. In Computer Taylor, R.H., Lavallée, S., Burdea, G.C., Mösges, R. (eds): Integrated Surgery: Technology and Clinical Applications. MIT Press, Cambridge MA (1996) 425-449
    • (1996) Integrated Surgery: Technology and Clinical Applications , pp. 425-449
    • Lavallée, S.1    Troccaz, J.2
  • 2
    • 1242309418 scopus 로고    scopus 로고
    • Ultrasound registration of the bone surface for surgical navigation
    • Amin, D., Kanade, T., DiGioia, A., Jaramaz, B.: Ultrasound registration of the bone surface for surgical navigation. Comp. Aid. Surg. 8 (2003) 1-16
    • (2003) Comp. Aid. Surg. , vol.8 , pp. 1-16
    • Amin, D.1    Kanade, T.2    DiGioia, A.3    Jaramaz, B.4
  • 3
    • 0346220302 scopus 로고    scopus 로고
    • A-mode ultrasound-based registration in computer-aided surgery of the skull
    • Amstutz, C., Caversaccio, M., et al.: A-mode ultrasound-based registration in computer-aided surgery of the skull. Arch. Otolaryngol. Head Neck Surg. 129 (2003)1310-1316
    • (2003) Arch. Otolaryngol. Head Neck Surg. , vol.129 , pp. 1310-1316
    • Amstutz, C.1    Caversaccio, M.2
  • 4
    • 0032178167 scopus 로고    scopus 로고
    • The Otto Aufranc Award. Image guided navigation system to measure intraoperatively acetabular implant alignment
    • DiGioia, A.M., Jaramaz, B., et al.: The Otto Aufranc Award. Image guided navigation system to measure intraoperatively acetabular implant alignment. Clin. Orthop. 355 (1998) 8-22
    • (1998) Clin. Orthop. , vol.355 , pp. 8-22
    • DiGioia, A.M.1    Jaramaz, B.2
  • 5
    • 0041825426 scopus 로고    scopus 로고
    • Robust registration for computer-integrated orthopedic surgery: Laboratory validation and clinical experience
    • Ma, B. and Ellis, R.B.: Robust registration for computer-integrated orthopedic surgery: laboratory validation and clinical experience. Med. Image Anal. 7 (2003) 237-250
    • (2003) Med. Image Anal. , vol.7 , pp. 237-250
    • Ma, B.1    Ellis, R.B.2
  • 6
    • 0036388104 scopus 로고    scopus 로고
    • Bone morphing: 3D morphological data for total knee arthroplasty
    • Stindel, E., Briard, J., et al.: Bone morphing: 3D morphological data for total knee arthroplasty. Comp. Aid. Surg. 7 (2002) 156-168
    • (2002) Comp. Aid. Surg. , vol.7 , pp. 156-168
    • Stindel, E.1    Briard, J.2
  • 7
    • 13644249894 scopus 로고    scopus 로고
    • A review of calibration techniques for freehand 3-D ultrasound systems
    • Mercier, L., Lango, T., Lindseth, F., Collins, L.D.: A review of calibration techniques for freehand 3-D ultrasound systems. Ultrasound Med. Biol. 31 (2005) 143-165
    • (2005) Ultrasound Med. Biol. , vol.31 , pp. 143-165
    • Mercier, L.1    Lango, T.2    Lindseth, F.3    Collins, L.D.4
  • 8
    • 0041874983 scopus 로고    scopus 로고
    • Robust registration of 2D and 3D point sets
    • Fitzgibbon, A.: Robust registration of 2D and 3D point sets. Proc. B.M.V.C. (2001) 411-420
    • (2001) Proc. B.M.V.C. , pp. 411-420
    • Fitzgibbon, A.1
  • 9
    • 0035670075 scopus 로고    scopus 로고
    • Accuracy of an electromagnetic three-dimensional ultrasound system for carotid artery imaging
    • Barratt, D., Davies, A., et al.: Accuracy of an electromagnetic three-dimensional ultrasound system for carotid artery imaging. Ultrasound Med. Biol. 27 (2001) 1421-1425
    • (2001) Ultrasound Med. Biol. , vol.27 , pp. 1421-1425
    • Barratt, D.1    Davies, A.2
  • 10
    • 0032994668 scopus 로고    scopus 로고
    • Pelvis and lower limb anatomical calibration precision and its propagation to bone geometry and joint angles
    • della Croce, U., Cappozzo, A., Kerrigan, D.: Pelvis and lower limb anatomical calibration precision and its propagation to bone geometry and joint angles. Med. Biol. Eng. Comput. 37 (1999) 155-161
    • (1999) Med. Biol. Eng. Comput. , vol.37 , pp. 155-161
    • Della Croce, U.1    Cappozzo, A.2    Kerrigan, D.3
  • 11
    • 0032173355 scopus 로고    scopus 로고
    • Predicting error in rigid-body point-based registration
    • Fitzpatrick, M., West, J., Maurer, C.: Predicting error in rigid-body point-based registration. IEEE Trans. Med. Imag. 17 (1998) 694-702
    • (1998) IEEE Trans. Med. Imag. , vol.17 , pp. 694-702
    • Fitzpatrick, M.1    West, J.2    Maurer, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.